Changes for page End Device Frequency Band
Last modified by Edwin Chen on 2024/10/21 20:35
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% class="wikigeneratedid" id="HEndDeviceFrequencyBand" %) 2 - **Contents:** 2 + **Table of** **Contents:** 3 3 4 4 {{toc/}} 5 5 ... ... @@ -8,31 +8,31 @@ 8 8 9 9 = 1. Introduction = 10 10 11 + 11 11 This page list the default frequency band for Dragino End Devices. The frequency bands are base on TTN Frequency Bands. User can modify upgrade firmware to support different frequency band or use AT Command to change the sub band in some frequency bands. 12 12 13 13 * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]] 14 14 * Frequency Bands vs Country List : Page 11 of [[LoRaWAN Regional Parameters RP2-1.0.3>>url:https://resources.lora-alliance.org/technical-specifications/rp2-1-0-3-lorawan-regional-parameters]] 15 15 16 - 17 17 = 2. OTAA Join Behaviour = 18 18 19 -For 005 LoRaWAN stack: to save battery, once boot, device will make first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again. 20 20 20 +Since 005 LoRaWAN stack: to save battery, once boot, device will first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again. 21 + 21 21 ((( 22 - For005 LoRaWAN Stack:23 +Since 005 LoRaWAN Stack: 23 23 ))) 24 24 25 25 * EU868 OTAA Join DR select. SF7->SF8->SF9->SF10->SF11->SF12; Each 3 attempts and then loop 26 -* US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels to join and it will be set to use the proper sub-band after Join success 27 +* US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels (All sub-bands) to join and it will be set to use the proper sub-band after Join success 27 27 28 - 29 29 = 3. Default Frequency Bands = 30 30 31 - 32 32 == 3.1 AS923 == 33 33 34 34 === 3.1.1 Notice for AS923 Frequency Bands === 35 35 35 + 36 36 ((( 37 37 Since [[RP002-1.0.1LoRaWAN Regional Parameters>>url:https://lora-alliance.org/sites/default/files/2020-02/rp_2-1.0.1.pdf]], AS923 include three different default settings for different countries: AS923-1, AS923-2 and AS923-3. 38 38 ))) ... ... @@ -44,6 +44,7 @@ 44 44 45 45 === 3.1.2 AS920-923 & AS923-925 : AS923-1 (AS923) === 46 46 47 + 47 47 * **Countries**: Malaysia, 48 48 * Default Uplink channel: 49 49 ** 923.2 - SF7BW125 to SF10BW125 ... ... @@ -70,9 +70,9 @@ 70 70 ** Uplink channels 1-8 (RX1) 71 71 ** 923.2 - SF10BW125 (RX2) 72 72 73 - 74 74 === 3.1.3 AS923-2 === 75 75 76 + 76 76 * Default Uplink channel: 77 77 ** 921.4 - SF7BW125 to SF10BW125 78 78 ** 921.6 - SF7BW125 to SF10BW125 ... ... @@ -83,9 +83,9 @@ 83 83 ** Uplink channels 1-8 (RX1) 84 84 ** 921.4 - SF10BW125 (RX2) 85 85 86 - 87 87 === 3.1.4 AS923-3 === 88 88 89 + 89 89 * Default Uplink channel: 90 90 ** 916.6 - SF7BW125 to SF10BW125 91 91 ** 916.8 - SF7BW125 to SF10BW125 ... ... @@ -96,9 +96,9 @@ 96 96 ** Uplink channels 1-8 (RX1) 97 97 ** 916.6 - SF10BW125 (RX2) 98 98 99 - 100 100 === 3.1.5 AS923-4 === 101 101 102 + 102 102 * Countries : Israel 103 103 * Default Uplink channel: 104 104 ** 917.3 - SF7BW125 to SF10BW125 ... ... @@ -109,9 +109,9 @@ 109 109 ** Uplink channels 1-8 (RX1) 110 110 ** 917.3 - SF10BW125 (RX2) 111 111 112 - 113 113 == 3.2 AU915-928(AU915) == 114 114 115 + 115 115 **Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]** , Default use CHE=2 116 116 117 117 * Uplink: ... ... @@ -153,13 +153,15 @@ 153 153 Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 154 154 ))) 155 155 * ((( 156 -Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)157 +Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 157 157 159 + 158 158 159 159 ))) 160 160 161 161 == 3.3 CN470-510 (CN470) == 162 162 165 + 163 163 Used in China, Default use CHE=1 164 164 165 165 * Uplink: ... ... @@ -183,9 +183,9 @@ 183 183 ** 508.1 - SF7BW125 to SF12BW125 184 184 ** 505.3 - SF12BW125 (RX2 downlink only) 185 185 186 - 187 187 == 3.4 EU863-870 (EU868) == 188 188 191 + 189 189 * Uplink: 190 190 ** 868.1 - SF7BW125 to SF12BW125 191 191 ** 868.3 - SF7BW125 to SF12BW125 and SF7BW250 ... ... @@ -206,6 +206,7 @@ 206 206 207 207 == 3.5 IN865-867 (IN865) == 208 208 212 + 209 209 * Uplink: 210 210 ** 865.0625 - SF7BW125 to SF12BW125 211 211 ** 865.4025 - SF7BW125 to SF12BW125 ... ... @@ -215,9 +215,20 @@ 215 215 ** Uplink channels 1-3 (RX1) 216 216 ** 866.550 - SF10BW125 (RX2) 217 217 222 +Gateway has below eight channels in IN865 bands. 218 218 224 +* 865.0625 - SF7BW125 to SF12BW125 225 +* 865.4025 - SF7BW125 to SF12BW125 226 +* 865.6025 - SF7BW125 to SF12BW125 227 +* 865.9850 - SF7BW125 to SF12BW125 228 +* 866.1850 - SF7BW125 to SF12BW125 229 +* 866.3850 - SF7BW125 to SF12BW125 230 +* 866.5850 - SF7BW125 to SF12BW125 231 +* 866.7850 - SF7BW125 to SF12BW125 232 + 219 219 == 3.6 KZ865 == 220 220 235 + 221 221 * Uplink ~-~- 125Khz , DR0 - DR5 222 222 ** 865.1 223 223 ** 865.2 ... ... @@ -229,9 +229,9 @@ 229 229 ** The RX1 receive window uses the same channel as the preceding uplink. 230 230 ** The RX2 receive window uses a fixed frequency and data rate. The default parameters are 866.7MHz / DR0 (SF12, 125 kHz) 231 231 232 - 233 233 == 3.7 KR920-923 (KR920) == 234 234 249 + 235 235 * Default channel: 236 236 ** 922.1 - SF7BW125 to SF12BW125 237 237 ** 922.3 - SF7BW125 to SF12BW125 ... ... @@ -250,9 +250,9 @@ 250 250 ** Uplink channels 1-7(RX1) 251 251 ** 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125) 252 252 253 - 254 254 == 3.8 MA869 == 255 255 270 + 256 256 Country: Morroco 257 257 258 258 * Uplink: ... ... @@ -270,14 +270,15 @@ 270 270 ** Uplink channels 1-9 (RX1) 271 271 ** 869.525 - SF12BW125 (RX2 downlink only) 272 272 273 - 274 274 == 3.9 US902-928 (US915) == 275 275 290 + 276 276 Used in USA, Canada and South America. 277 277 278 278 279 279 === 3.9.1 Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]. === 280 280 296 + 281 281 Default use CHE=2, Subband 2 282 282 283 283 * Uplink: ... ... @@ -301,21 +301,17 @@ 301 301 ** 927.5 - SF7BW500 to SF12BW500 302 302 ** 923.3 - SF12BW500(RX2 downlink only) 303 303 304 - 305 305 === 3.9.2 Latest firmware, Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]] === 306 306 322 + 307 307 ((( 308 308 There is an issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only work for the LoRaWAN server use sub-band2 , such as TTN. To solve this, the user needs to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvenient. 309 309 ))) 310 310 311 311 ((( 312 - 328 +So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join. In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will: 313 313 ))) 314 314 315 -((( 316 -So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join, In this case, In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will: 317 -))) 318 - 319 319 * ((( 320 320 Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that subband 321 321 ))) ... ... @@ -322,10 +322,40 @@ 322 322 * ((( 323 323 Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include) 324 324 337 + 325 325 326 326 ))) 327 327 328 328 = 4. Frequency Bands for different server = 329 329 343 + 330 330 * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]] 331 331 * Loriot [[https:~~/~~/docs.loriot.io/display/LNS/Regional+Frequency+Plans>>url:https://docs.loriot.io/display/LNS/Regional+Frequency+Plans]] 346 + 347 += 5. Subband Related questiones in US915, AU915, CN470 bands. = 348 + 349 + 350 +Frequency band US915, AU915 and CN470 supports totally 72 frequency in 8 sub-bands, Normally Gateway only support 8 channels ( one subband). So how does the gateway and end nodes work in such frequency? 351 + 352 + 353 +== 5.1 Set Subband in Gateway. == 354 + 355 + 356 +* If Gateway choose (% style="color:blue" %)**Semtech UDP packet**(%%) forwarder to Connect to LoRaWAN server. User need to manually set the match Subband in the gateway web UI. 357 + 358 +* If Gateway choose (% style="color:blue" %)**Basic Station Mode**(%%) to connect to the LoRaWAN server. User can set the subband in the Server side and gateway will the correct subband from server. no need to set this in gateway. AWS-IoT, TTN, ChirpStack all supports Basic Station Connection. 359 + 360 +== 5.2 Set Subband in End Node == 361 + 362 + 363 +* In early End Node firmware, it is pre-set to subband 2 , user need to manually set to proper subband if they don;t use subband 2. 364 + 365 +* In new end node firmware , it supports all sub-bands, and will swtich to the proper subband after OTAA join. So user can use the end node with all sub-band. 366 + 367 +Reference: [[How it affects the OTAA Join when end node is set to support all subbands>>http://wiki.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H13.WhyittakeslongertimeforOTAAjoinedinUS9152FCN4702FAU915band3F]]? 368 + 369 + 370 + 371 + 372 + 373 +