<
From version < 11.6 >
edited by Xiaoling
on 2022/06/01 11:46
To version < 3.8 >
edited by Xiaoling
on 2022/05/10 15:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,11 +1,8 @@
1 1  (% class="wikigeneratedid" id="HEndDeviceFrequencyBand" %)
2 - **Contents:**
2 +
3 3  
4 4  {{toc/}}
5 5  
6 -
7 -
8 -
9 9  = 1. Introduction =
10 10  
11 11  This page list the default frequency band for Dragino End Devices. The frequency bands are base on TTN Frequency Bands. User can modify upgrade firmware to support different frequency band or use AT Command to change the sub band in some frequency bands.
... ... @@ -13,8 +13,6 @@
13 13  * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]
14 14  * Frequency Bands vs Country List : Page 11 of [[LoRaWAN Regional Parameters RP2-1.0.3>>url:https://resources.lora-alliance.org/technical-specifications/rp2-1-0-3-lorawan-regional-parameters]]
15 15  
16 -
17 -
18 18  = 2. OTAA Join Behaviour =
19 19  
20 20  For 005 LoRaWAN stack: to save battery, once boot, device will make first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again.
... ... @@ -26,8 +26,6 @@
26 26  * EU868 OTAA Join DR select. SF7->SF8->SF9->SF10->SF11->SF12; Each 3 attempts and then loop
27 27  * US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels to join and it will be set to use the proper sub-band after Join success
28 28  
29 -
30 -
31 31  = 3. Default Frequency Bands =
32 32  
33 33  
... ... @@ -44,6 +44,7 @@
44 44  )))
45 45  
46 46  
40 +
47 47  === 3.1.2 AS920-923 & AS923-925 : AS923-1 (AS923) ===
48 48  
49 49  * Default Uplink channel:
... ... @@ -136,6 +136,9 @@
136 136  There is a issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only works for the LoRaWAN server use sub-band2 , such as TTN. To solve this, user need to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvinient.
137 137  )))
138 138  
133 +(((
134 +
135 +)))
139 139  
140 140  (((
141 141  So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
... ... @@ -151,8 +151,6 @@
151 151  )))
152 152  * (((
153 153  Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
154 -
155 -
156 156  )))
157 157  
158 158  == 3.3 CN470-510 (CN470) ==
... ... @@ -246,8 +246,6 @@
246 246  
247 247  == 3.8 MA869 ==
248 248  
249 - Country: Morroco
250 -
251 251  * Uplink:
252 252  ** 869.1 - SF7BW125 to SF12BW125
253 253  ** 869.3 - SF7BW125 to SF12BW125
... ... @@ -267,7 +267,6 @@
267 267  
268 268  Used in USA, Canada and South America.
269 269  
270 -
271 271  === 3.9.1 Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]. ===
272 272  
273 273  Default use CHE=2, Subband 2
... ... @@ -312,8 +312,6 @@
312 312  )))
313 313  * (((
314 314  Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include)
315 -
316 -
317 317  )))
318 318  
319 319  = 4. Frequency Bands for different server =
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0