Changes for page End Device Frequency Band
Last modified by Edwin Chen on 2024/10/21 20:35
<
edited by Edwin Chen
on 2024/10/21 20:35
on 2024/10/21 20:35
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% class="wikigeneratedid" id="HEndDeviceFrequencyBand" %) 2 - **Contents:** 2 + **Table of** **Contents:** 3 3 4 4 {{toc/}} 5 5 ... ... @@ -8,33 +8,32 @@ 8 8 9 9 = 1. Introduction = 10 10 11 + 11 11 This page list the default frequency band for Dragino End Devices. The frequency bands are base on TTN Frequency Bands. User can modify upgrade firmware to support different frequency band or use AT Command to change the sub band in some frequency bands. 12 12 13 13 * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]] 14 14 * Frequency Bands vs Country List : Page 11 of [[LoRaWAN Regional Parameters RP2-1.0.3>>url:https://resources.lora-alliance.org/technical-specifications/rp2-1-0-3-lorawan-regional-parameters]] 15 15 16 - 17 - 18 18 = 2. OTAA Join Behaviour = 19 19 20 - For005 LoRaWAN stack:to save battery, onceboot,devicewill make first make 200 tries for OTAA Join,thetime period of two Join Requests will depends on the DR and the airtimerequirement. After this200 Join finish, device will send a join requestevery 20 minutes. If device reboot, it willdo above loop again.19 +Since 005 LoRaWAN stack: One device boot or reset, it will 21 21 22 - (((23 - For 005LoRaWANStack:24 - )))21 +* First make 200 Join Requestes for OTAA Join, the interval of two Join Requests will depends on the DR and the airtime requirement. 22 +* After 200 Join Requestes, if end node still not join successful, to save battery life, it will keep sending join request at the default uplink interval ( 20 minutes) . 23 +* If device reboot, it will do above loop again. 25 25 26 -* EU868 OTAA Join DR select. SF7->SF8->SF9->SF10->SF11->SF12; Each 3 attempts and then loop 27 -* US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels to join and it will be set to use the proper sub-band after Join success 25 +Since 005 LoRaWAN Stack: 28 28 27 +* **EU868 OTAA Join DR Logic**. SF7->SF8->SF9->SF10->SF11->SF12; Each SF will make 3 attempts and then loop 28 +* **US915 and AU915 OTAA Join procedure**,. End node by default will use all 72 channels (All sub-bands) to join and it will be set to use the proper sub-band after Join success 29 29 30 - 31 31 = 3. Default Frequency Bands = 32 32 33 - 34 34 == 3.1 AS923 == 35 35 36 36 === 3.1.1 Notice for AS923 Frequency Bands === 37 37 36 + 38 38 ((( 39 39 Since [[RP002-1.0.1LoRaWAN Regional Parameters>>url:https://lora-alliance.org/sites/default/files/2020-02/rp_2-1.0.1.pdf]], AS923 include three different default settings for different countries: AS923-1, AS923-2 and AS923-3. 40 40 ))) ... ... @@ -46,6 +46,8 @@ 46 46 47 47 === 3.1.2 AS920-923 & AS923-925 : AS923-1 (AS923) === 48 48 48 + 49 +* **Countries**: Malaysia, 49 49 * Default Uplink channel: 50 50 ** 923.2 - SF7BW125 to SF10BW125 51 51 ** 923.4 - SF7BW125 to SF10BW125 ... ... @@ -71,10 +71,9 @@ 71 71 ** Uplink channels 1-8 (RX1) 72 72 ** 923.2 - SF10BW125 (RX2) 73 73 74 - 75 - 76 76 === 3.1.3 AS923-2 === 77 77 77 + 78 78 * Default Uplink channel: 79 79 ** 921.4 - SF7BW125 to SF10BW125 80 80 ** 921.6 - SF7BW125 to SF10BW125 ... ... @@ -85,10 +85,9 @@ 85 85 ** Uplink channels 1-8 (RX1) 86 86 ** 921.4 - SF10BW125 (RX2) 87 87 88 - 89 - 90 90 === 3.1.4 AS923-3 === 91 91 90 + 92 92 * Default Uplink channel: 93 93 ** 916.6 - SF7BW125 to SF10BW125 94 94 ** 916.8 - SF7BW125 to SF10BW125 ... ... @@ -99,10 +99,9 @@ 99 99 ** Uplink channels 1-8 (RX1) 100 100 ** 916.6 - SF10BW125 (RX2) 101 101 102 - 103 - 104 104 === 3.1.5 AS923-4 === 105 105 103 + 106 106 * Countries : Israel 107 107 * Default Uplink channel: 108 108 ** 917.3 - SF7BW125 to SF10BW125 ... ... @@ -113,10 +113,9 @@ 113 113 ** Uplink channels 1-8 (RX1) 114 114 ** 917.3 - SF10BW125 (RX2) 115 115 116 - 117 - 118 118 == 3.2 AU915-928(AU915) == 119 119 116 + 120 120 **Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]** , Default use CHE=2 121 121 122 122 * Uplink: ... ... @@ -158,13 +158,15 @@ 158 158 Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 159 159 ))) 160 160 * ((( 161 -Use the Join successful sub-band if the server doesn ’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)158 +Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 162 162 160 + 163 163 164 164 ))) 165 165 166 166 == 3.3 CN470-510 (CN470) == 167 167 166 + 168 168 Used in China, Default use CHE=1 169 169 170 170 * Uplink: ... ... @@ -188,10 +188,9 @@ 188 188 ** 508.1 - SF7BW125 to SF12BW125 189 189 ** 505.3 - SF12BW125 (RX2 downlink only) 190 190 191 - 192 - 193 193 == 3.4 EU863-870 (EU868) == 194 194 192 + 195 195 * Uplink: 196 196 ** 868.1 - SF7BW125 to SF12BW125 197 197 ** 868.3 - SF7BW125 to SF12BW125 and SF7BW250 ... ... @@ -212,6 +212,7 @@ 212 212 213 213 == 3.5 IN865-867 (IN865) == 214 214 213 + 215 215 * Uplink: 216 216 ** 865.0625 - SF7BW125 to SF12BW125 217 217 ** 865.4025 - SF7BW125 to SF12BW125 ... ... @@ -221,10 +221,20 @@ 221 221 ** Uplink channels 1-3 (RX1) 222 222 ** 866.550 - SF10BW125 (RX2) 223 223 223 +Gateway has below eight channels in IN865 bands. 224 224 225 +* 865.0625 - SF7BW125 to SF12BW125 226 +* 865.4025 - SF7BW125 to SF12BW125 227 +* 865.6025 - SF7BW125 to SF12BW125 228 +* 865.9850 - SF7BW125 to SF12BW125 229 +* 866.1850 - SF7BW125 to SF12BW125 230 +* 866.3850 - SF7BW125 to SF12BW125 231 +* 866.5850 - SF7BW125 to SF12BW125 232 +* 866.7850 - SF7BW125 to SF12BW125 225 225 226 226 == 3.6 KZ865 == 227 227 236 + 228 228 * Uplink ~-~- 125Khz , DR0 - DR5 229 229 ** 865.1 230 230 ** 865.2 ... ... @@ -236,10 +236,9 @@ 236 236 ** The RX1 receive window uses the same channel as the preceding uplink. 237 237 ** The RX2 receive window uses a fixed frequency and data rate. The default parameters are 866.7MHz / DR0 (SF12, 125 kHz) 238 238 239 - 240 - 241 241 == 3.7 KR920-923 (KR920) == 242 242 250 + 243 243 * Default channel: 244 244 ** 922.1 - SF7BW125 to SF12BW125 245 245 ** 922.3 - SF7BW125 to SF12BW125 ... ... @@ -258,10 +258,9 @@ 258 258 ** Uplink channels 1-7(RX1) 259 259 ** 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125) 260 260 261 - 262 - 263 263 == 3.8 MA869 == 264 264 271 + 265 265 Country: Morroco 266 266 267 267 * Uplink: ... ... @@ -279,15 +279,15 @@ 279 279 ** Uplink channels 1-9 (RX1) 280 280 ** 869.525 - SF12BW125 (RX2 downlink only) 281 281 282 - 283 - 284 284 == 3.9 US902-928 (US915) == 285 285 291 + 286 286 Used in USA, Canada and South America. 287 287 288 288 289 289 === 3.9.1 Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]. === 290 290 297 + 291 291 Default use CHE=2, Subband 2 292 292 293 293 * Uplink: ... ... @@ -313,18 +313,15 @@ 313 313 314 314 === 3.9.2 Latest firmware, Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]] === 315 315 323 + 316 316 ((( 317 317 There is an issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only work for the LoRaWAN server use sub-band2 , such as TTN. To solve this, the user needs to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvenient. 318 318 ))) 319 319 320 320 ((( 321 - 329 +So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join. In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will: 322 322 ))) 323 323 324 -((( 325 -So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join, In this case, In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will: 326 -))) 327 - 328 328 * ((( 329 329 Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that subband 330 330 ))) ... ... @@ -331,10 +331,48 @@ 331 331 * ((( 332 332 Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include) 333 333 338 + 334 334 335 335 ))) 336 336 337 337 = 4. Frequency Bands for different server = 338 338 344 + 339 339 * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]] 340 340 * Loriot [[https:~~/~~/docs.loriot.io/display/LNS/Regional+Frequency+Plans>>url:https://docs.loriot.io/display/LNS/Regional+Frequency+Plans]] 347 + 348 + 349 += 5. Subband Related questiones in US915, AU915, CN470 bands. = 350 + 351 + 352 +Frequency band US915, AU915 and CN470 supports totally 72 frequency in 8 sub-bands, Normally Gateway only support 8 channels ( one subband). So how does the gateway and end nodes work in such frequency? 353 + 354 + 355 +== 5.1 Set Subband in Gateway. == 356 + 357 + 358 +* If Gateway choose (% style="color:blue" %)**Semtech UDP packet**(%%) forwarder to Connect to LoRaWAN server. User need to manually set the match Subband in the gateway web UI. 359 + 360 +* If Gateway choose (% style="color:blue" %)**Basic Station Mode**(%%) to connect to the LoRaWAN server. User can set the subband in the Server side and gateway will the correct subband from server. no need to set this in gateway. AWS-IoT, TTN, ChirpStack all supports Basic Station Connection. 361 + 362 +== 5.2 Set Subband in End Node == 363 + 364 + 365 +* In early End Node firmware, it is pre-set to subband 2 , user need to manually set to proper subband if they don;t use subband 2. 366 + 367 +* In new end node firmware , it supports all sub-bands, and will swtich to the proper subband after OTAA join. So user can use the end node with all sub-band. 368 + 369 +Reference: [[How it affects the OTAA Join when end node is set to support all subbands>>http://wiki.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H13.WhyittakeslongertimeforOTAAjoinedinUS9152FCN4702FAU915band3F]]? 370 + 371 + 372 += 6. Data Rate and TXP auto-adjust logic. = 373 + 374 +In below cases the sensor end node will auto-adjust. (ADR must set to 1) 375 + 376 +* Auto-just according to the server ADR request change downlink command. 377 +* If there is no adr_req_ack arrive the sensor end node for more than 64 uplinks, end node will set the output to maximum power (AT+TXP=0). 378 +* If there is no adr_req_ack arrive the sensor end node for more than 96 uplinks, end node will reduce the Data Rate by 1. 379 + 380 + 381 + 382 +