Changes for page End Device AT Commands and Downlink Command
Last modified by Mengting Qiu on 2025/07/01 15:53
From version 81.7
edited by Mengting Qiu
on 2025/07/01 15:30
on 2025/07/01 15:30
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.kai - Content
-
... ... @@ -18,9 +18,6 @@ 18 18 ))) 19 19 20 20 21 - 22 - 23 - 24 24 = 2. How to use AT Commands or Downlink command = 25 25 26 26 ... ... @@ -258,9 +258,9 @@ 258 258 * 0x05: KZ865 259 259 * 0x06: RU864 260 260 * 0x07: AS923 261 -* 0x08: AS923- 2262 -* 0x09: AS923- 3263 -* 0xa0: AS923- 4258 +* 0x08: AS923-1 259 +* 0x09: AS923-2 260 +* 0xa0: AS923-3 264 264 265 265 ((( 266 266 ... ... @@ -292,60 +292,6 @@ 292 292 293 293 (% style="display:none" %) (%%) 294 294 295 -== 4.6 Get or Set time synchronization method(The network server must support LoRaWAN v1.0.3) == 296 - 297 - 298 -Feature: Set the system time synchronization. 299 - 300 -(% style="color:blue" %)**AT Command: AT+SYNCMOD** 301 - 302 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:727.222px" %) 303 -|(% style="background-color:#4f81bd; color:white; width:165px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:227px" %)**Function**|(% style="background-color:#4f81bd; color:white; width:329px" %)**Response** 304 -|(% style="width:165px" %)AT+SYNCMOD=?|(% style="width:227px" %)Get the current time synchronization configuration|(% style="width:329px" %)((( 305 -1,0(Default) 306 - 307 -((( 308 -OK 309 -))) 310 -))) 311 -|(% style="width:165px" %)AT+SYNCMOD=1,8|(% style="width:227px" %)Set the time to UTC+8 time display.|(% style="width:329px" %)OK 312 - 313 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:727.222px" %) 314 -|(% style="background-color:#4f81bd; color:white; width:165px" %)**Command format**|(% style="background-color:#4f81bd; color:white; width:227px" %)**Parameters**|(% style="background-color:#4f81bd; color:white; width:329px" %)**Explanation** 315 -|(% style="width:165px" %)AT+SYNCMOD=a,|(% style="width:227px" %)Get the current time synchronization configuration|(% style="width:329px" %)((( 316 -1,0(Default) 317 - 318 -((( 319 -OK 320 -))) 321 -))) 322 -|(% style="width:165px" %)AT+SYNCMOD=1,8|(% style="width:227px" %)Set the time to UTC+8 time display.|(% style="width:329px" %)OK 323 - 324 - 325 - 326 - 327 - AT+SYNCMOD=1,bb 328 - 329 -* ((( 330 -1: Set the system time synchronization 331 -))) 332 - 333 - bb: Set local time (24 zones): -12~~12 334 - 335 -* ((( 336 -Example: AT+SYNCMOD=1,8 ~/~/Set the time to UTC+8 time display. 337 -))) 338 -* ((( 339 -Downlink payload:28 01 xx 340 - 341 -Example: downlink 0x280108 ~-~-~-~-->AT+SYNCMOD=1,8 342 -))) 343 - 344 -Note: This command takes effect after the node is reset, or after downlink 0x2601(query device status). 345 - 346 - 347 - 348 - 349 349 = 5. Keys, IDs and EUIs management = 350 350 351 351 == 5.1 Application EUI == ... ... @@ -1141,22 +1141,7 @@ 1141 1141 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 1142 1142 ))) 1143 1143 1144 -**Example:** 1145 -~1. Set AT+RX1WTO=0, AT+RX1DL=5000, the window opening time is: 53.699ms 1146 1146 1147 -[[image:image-20240906095336-1.png||height="404" width="759"]] 1148 - 1149 - 1150 -2. Set AT+RX1WTO=128, AT+RX1DL=5000, the window opening time is: 149.644ms 1151 - 1152 -[[image:image-20240906095433-2.png||height="403" width="756"]] 1153 - 1154 - 1155 -3. Set AT+RX1WTO=128, AT+RX1DL=5000, the window opening time is: 298.221ms 1156 - 1157 -[[image:image-20240906095527-3.png||height="400" width="749"]] 1158 - 1159 - 1160 1160 == 7.21 Get or Set RXwindows2 timeout == 1161 1161 1162 1162 ... ... @@ -1172,22 +1172,8 @@ 1172 1172 ))) 1173 1173 |(% style="width:162px" %)AT+RX2WTO=20|(% style="width:192px" %)Set RXwindows2 timeout|(% style="width:90px" %)OK 1174 1174 1175 -**Example:** 1176 -~1. Set AT+RX2WTO=0, AT+RX2DL=6000, the window opening time is: 48.435ms 1103 +(% style="display:none" %) (%%) 1177 1177 1178 -(% style="display:none" %) (%%) [[image:image-20240906095619-4.png||height="375" width="703"]] 1179 - 1180 - 1181 -2. Set AT+RX2WTO=128, AT+RX2DL=6000, the window opening time is: 3011ms 1182 - 1183 -[[image:image-20240906095726-5.png||height="381" width="714"]] 1184 - 1185 - 1186 -3. Set AT+RX2WTO=255, AT+RX2DL=6000, the window opening time is: 3009ms 1187 - 1188 -[[image:image-20240906095811-6.png||height="380" width="711"]] 1189 - 1190 - 1191 1191 == 7.22 Setting up uplinkdwelltime (as923, au915) == 1192 1192 1193 1193