... ... @@ -31,15 +31,15 @@
31 31  = 3. Support End Node and firmware version =
32 32  
33 33  
34 -(% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
35 -|=(% colspan="3" style="width: 963px;" %)(((
34 +(% border="1" style="background-color:#F2F2F2; width:966px" %)
35 +|=(% colspan="3" style="width: 963px;background-color:#D9E2F3" %)(((
36 36  Dragino STM32 base hardware Firmware / LoRaWAN stack list
37 37  )))
38 -|(% style="width:187px" %)(((
38 +|(% style="width:187px;color:#0070C0" %)(((
39 39  **Model**
40 -)))|(% style="width:330px" %)(((
40 +)))|(% style="width:330px;color:#0070C0" %)(((
41 41  **Description**
42 -)))|(% style="width:445px" %)(((
42 +)))|(% style="width:445px;color:#0070C0" %)(((
43 43  **Firmware Version <~-~-> Stack Version**
44 44  )))
45 45  |(% style="width:187px" %)(((
... ... @@ -114,9 +114,9 @@
114 114  
115 115  (% style="color:blue" %)**AT Command: AT+TDC**
116 116  
117 -(% border="1" style="background-color:#ffffcc; color:green; width:727.222px" %)
118 -|=(% colspan="3" style="width: 724px;" %)AT+TDC
119 -|(% style="width:165px" %)**Command Example**|(% style="width:227px" %)**Function**|(% style="width:329px" %)**Response**
117 +(% border="1" style="background-color:#F2F2F2; width:727.222px" %)
118 +|=(% colspan="3" style="width: 724px;background-color:#D9E2F3;color:#037691" %)AT+TDC
119 +|(% style="width:165px;color:#0070C0" %)**Command Example**|(% style="width:227px;color:#0070C0" %)**Function**|(% style="width:329px;color:#0070C0" %)**Response**
120 120  |(% style="width:165px" %)AT+TDC=?|(% style="width:227px" %)Show current transmit Interval|(% style="width:329px" %)30000(((
121 121  OK
122 122  
... ... @@ -711,8 +711,13 @@
711 711  
712 712  )))
713 713  
714 -(% style="display:none" %) (%%)
714 +(% style="display:none" %)
715 715  
716 +(% style="color:red" %)**Notice:**
717 +
718 +* Run AT+FDR before running AT+CLASS=C
719 +* After change to Class=C, Before OTAA Join Successfule, the end node will still shows to use CLASS=A for OTAA Joined. It will use CLASS=C after OTAA Join Succeccful.