Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,18 +23,18 @@ 23 23 24 24 = 3. Support End Node and firmware version = 25 25 26 -(% border="1"style="background-color:#ffffcc; color:green; width:942.222px" %)27 -|=(% colspan="3" style="width: 9 39px;" %)28 -|(% style="width:187px" %)**Model**|(% style="width:3 06px" %)**Description**|(% style="width:443px" %)**Firmware Version <~-~-> Stack Version**29 -|(% style="width:187px" %)[[LSN50-v1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/128-lsn50.html]], [[LSN50-V2>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/155-lsn50-v2.html]],|(% style="width:3 06px" %)Open Source Generic LoRaWAN Sensor Node|(% style="width:443px" %)LSN50 v1.6.0 <~-~-> DR-LWS-003;(((26 +(% style="background-color:#ffffcc; color:green; width:995.222px" %) 27 +|=(% colspan="3" style="width: 992px;" %)Dragino STM32 base hardware Firmware / LoRaWAN stack list 28 +|(% style="width:187px" %)**Model**|(% style="width:349px" %)**Description**|(% style="width:453px" %)**Firmware Version <~-~-> Stack Version** 29 +|(% style="width:187px" %)[[LSN50-v1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/128-lsn50.html]], [[LSN50-V2>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/155-lsn50-v2.html]],|(% style="width:349px" %)Open Source Generic LoRaWAN Sensor Node|(% style="width:453px" %)LSN50 v1.6.0 <~-~-> DR-LWS-003;((( 30 30 LSN50 v1.7.0 <~-~-> DR-LWS-005; ~-~-> Support since this version 31 31 ))) 32 -|(% style="width:187px" %)[[LGT92>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/142-lgt-92.html]],|(% style="width:3 06px" %)LoRaWAN GPS Tracker|(% style="width:443px" %)LGT92 v1.6.3 <~-~-> DR-LWS-003;(((32 +|(% style="width:187px" %)[[LGT92>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/142-lgt-92.html]],|(% style="width:349px" %)LoRaWAN GPS Tracker|(% style="width:453px" %)LGT92 v1.6.3 <~-~-> DR-LWS-003;((( 33 33 LGT92 v1.6.4 <~-~-> DR-LWS-005;~-~-> Support since this version 34 34 ))) 35 -|(% style="width:187px" %)[[LBT1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/165-lbt1.html]],|(% style="width:3 06px" %)LoRaWAN BLE Indoor Tracker|(% style="width:443px" %)LBT1 v1.0 <~-~-> DR-LWS-005;36 -|(% style="width:187px" %)[[RS485-LN>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/154-rs485-ln.html]],|(% style="width:3 06px" %)LoRaWAN RS485 Modbus Converter|(% style="width:443px" %)RS485-LN v1.3 <~-~-> DR-LWS-005;37 -|(% style="width:187px" %)[[LHT65>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/151-lht65.html]],|(% style="width:3 06px" %)LoRaWAN Temperature & Humidity Sensor|(% style="width:443px" %)LHT65 v1.7 <~-~-> DR-LWS-003;(((35 +|(% style="width:187px" %)[[LBT1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/165-lbt1.html]],|(% style="width:349px" %)LoRaWAN BLE Indoor Tracker|(% style="width:453px" %)LBT1 v1.0 <~-~-> DR-LWS-005; 36 +|(% style="width:187px" %)[[RS485-LN>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/154-rs485-ln.html]],|(% style="width:349px" %)LoRaWAN RS485 Modbus Converter|(% style="width:453px" %)RS485-LN v1.3 <~-~-> DR-LWS-005; 37 +|(% style="width:187px" %)[[LHT65>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/151-lht65.html]],|(% style="width:349px" %)LoRaWAN Temperature & Humidity Sensor|(% style="width:453px" %)LHT65 v1.7 <~-~-> DR-LWS-003;((( 38 38 LHT65 v1.8.0 <~-~-> DR-LWS-005;~-~-> Support since this version 39 39 ))) 40 40 ... ... @@ -46,11 +46,11 @@ 46 46 47 47 (% class="box infomessage" %) 48 48 ((( 49 -AT Command: AT+TDC 49 +**AT Command: AT+TDC** 50 50 ))) 51 51 52 -(% border="1"style="background-color:#ffffcc; color:green; width:727.222px" %)53 -|=(% colspan="3" style="width: 724px;" %) 52 +(% style="background-color:#ffffcc; color:green; width:727.222px" %) 53 +|=(% colspan="3" style="width: 724px;" %)AT+TDC 54 54 |(% style="width:165px" %)**Command Example**|(% style="width:227px" %)**Function**|(% style="width:329px" %)**Response** 55 55 |(% style="width:165px" %)AT+TDC=?|(% style="width:227px" %)Show current transmit Interval|(% style="width:329px" %)30000((( 56 56 OK ... ... @@ -61,7 +61,9 @@ 61 61 Set transmit interval to 60000ms = 60 seconds 62 62 ))) 63 63 64 +{{info}} 64 64 **Downlink Command: 0x01** 66 +{{/info}} 65 65 66 66 Format: Command Code (0x01) followed by 3 bytes time value. 67 67 ... ... @@ -75,15 +75,13 @@ 75 75 Feature: Reboot End Node to perform a new OTAA or ABP Join. 76 76 77 77 {{info}} 78 -AT Command: ATZ 80 +**AT Command: ATZ** 79 79 {{/info}} 80 80 81 -(% border=" 1" style="background-color:#ffffcc; color:green; width:727.222px" %)83 +(% border="0" style="background-color:#ffffcc; color:green; width:727.222px" %) 82 82 |=(% colspan="3" %)ATZ: Trig a reset of the MCU 83 83 |**Command Example**|**Function**|**Response** 84 -))) 85 -|ATZ|Reset MCU| 86 -((( 86 +|ATZ|Reset MCU|((( 87 87 Device reset and show booting info 88 88 89 89 LSN50 Device/LoRa ST Module ... ... @@ -97,35 +97,46 @@ 97 97 <followed by the Tx and Rx information> 98 98 ))) 99 99 100 -Downlink Command: 0x04 100 +{{info}} 101 +**Downlink Command: 0x04** 102 +{{/info}} 101 101 102 102 Format: Command Code (0x04) followed by FF. 103 103 104 -If the downlink payload=04FF, the end node will reboot. 106 +If the downlink payload=**04FF**, the end node will reboot. 105 105 106 106 == 4.3 Reset to factory Default == 107 107 108 108 Feature: Reset the parameters to Factory Default, factory default value depends on the firmware settings, the OTAA and ABP keys will reserve after this command. 109 109 110 -AT Command: AT+FDR 112 +{{info}} 113 +**AT Command: AT+FDR** 114 +{{/info}} 111 111 112 -|=(% colspan="3" %)Reset to factory default 113 -|**Command Example**|**Function**|**Response** 114 -|AT+FDR|Reset to factory default|Device reset to factory default parameters and show booting info 116 +(% style="background-color:#ffffcc; color:green; width:831.222px" %) 117 +|=(% colspan="3" style="width: 828px;" %)Reset to factory default 118 +|(% style="width:181px" %)**Command Example**|(% style="width:181px" %)**Function**|(% style="width:465px" %)**Response** 119 +|(% style="width:181px" %)AT+FDR|(% style="width:181px" %)Reset to factory default|(% style="width:465px" %)((( 120 +Device reset to factory default parameters and show booting info 115 115 116 -{{{LSN50 Device/LoRa ST Module 122 +LSN50 Device/LoRa ST Module 123 + 117 117 Image Version: XX 125 + 118 118 Frequency Band: XX 127 + 119 119 DevEui= XX XX XX XX XX XX XX XX 129 + 120 120 Please set the parameters or reset Device to apply change 121 - }}}131 +))) 122 122 133 +{{info}} 134 +**Downlink Command: 0x04** 135 +{{/info}} 123 123 124 -Downlink Command: 0x04 125 - 126 126 Format: Command Code (0x04) followed by FE. 127 127 128 -If the downlink payload=04FE, Reset Parameters to Factory Default, Keys Reserve. 139 +If the downlink payload=**04FE**, Reset Parameters to Factory Default, Keys Reserve. 129 129 130 130 131 131 == 4.4 Show Firmware Version == ... ... @@ -132,30 +132,34 @@ 132 132 133 133 Feature: Show firmware version. No downlink command yet. 134 134 135 -AT Command: AT+VER 146 +{{info}} 147 +**AT Command: AT+VER** 148 +{{/info}} 136 136 150 +(% style="background-color:#ffffcc; color:green" %) 137 137 |=(% colspan="3" %)AT+VER: Image Version and Frequency Band 138 138 |**Command Example**|**Function**|**Response** 139 -|AT+VER=?|Show Image version and Frequency Band| 153 +|AT+VER=?|Show Image version and Frequency Band|((( 154 +1.3 EU868 140 140 141 -{{{1.3 EU868 142 142 OK 143 - }}}157 +))) 144 144 159 +{{info}} 160 +**Downlink Command: 0x26 (Valid in 006 stack)** 161 +{{/info}} 145 145 146 -Downlink Command: 0x26 (Valid in 006 stack) 147 - 148 148 Downlink Format: 0x26 149 149 150 150 Device will reply with firmware version info, device info. frequency band info. detail please check device user manual. Total 5 bytes Example: If device is of firmware version 1.1.0 Upload: xx ~-~- yy ~-~- zz ~-~- 110 total 5 bytes 151 151 152 -xx: Software Type: 167 +**xx: Software Type:** 153 153 154 154 * 0x00 01: LGT92 Version 155 155 * 0x00 02: LBT1 156 156 * 0x00 03: LSE01/LDDS75/LDDS20/LSPH01/LLMS01/LSNPK01 157 157 158 -yy: Frequency Band: 173 +**yy: Frequency Band:** 159 159 160 160 * 0x01: EU868 161 161 * 0x02: US915 ... ... @@ -168,7 +168,7 @@ 168 168 * 0x09: AS923-2 169 169 * 0xa0: AS923-3 170 170 171 -zz: Subband 186 +**zz: Subband** 172 172 173 173 firmware version: v1.1.0 ~-~-> 110 174 174 ... ... @@ -177,19 +177,26 @@ 177 177 178 178 Feature: Show All configure. No downlink command yet. 179 179 180 -AT Command: AT+CFG 195 +{{info}} 196 +**AT Command: AT+CFG** 197 +{{/info}} 181 181 182 -|=(% colspan="3" %)AT+CFG: Print all configurations 183 -|**Command Example**|**Function**|**Response** 184 -|AT+CFG|Show all configures| 199 +(% style="background-color:#ffffcc; color:green; width:599.222px" %) 200 +|=(% colspan="3" style="width: 596px;" %)AT+CFG: Print all configurations 201 +|(% style="width:160px" %)**Command Example**|(% style="width:154px" %)**Function**|(% style="width:280px" %)**Response** 202 +|(% style="width:160px" %)AT+CFG|(% style="width:154px" %)Show all configures|(% style="width:280px" %)((( 203 +AT+DEUI = XX XX XX XX XX XX XX XX 185 185 186 -{{{AT+DEUI = XX XX XX XX XX XX XX XX 187 187 AT+DADDR=XXXXXXXX 206 + 188 188 ………. 208 + 189 189 AT+RX2WTO=X 210 + 190 190 AT+CHS=868100000 212 + 191 191 OK 192 - }}}214 +))) 193 193 194 194 195 195 = 5. Keys, IDs and EUIs management = ... ... @@ -198,27 +198,33 @@ 198 198 199 199 Feature: Get or Set the Application EUI. 200 200 201 -AT Command: AT+APPEUI 223 +{{info}} 224 +**AT Command: AT+APPEUI** 225 +{{/info}} 202 202 203 -|=(% colspan="3" %)AT+APPEUI 204 -|**Command Example**|**Function**|**Response** 205 -|AT+APPEUI=?|Get the Application EUI|00 b3 d5 00 00 00 00 00((( 227 +(% style="background-color:#ffffcc; color:green; width:686.222px" %) 228 +|=(% colspan="3" style="width: 683px;" %)AT+APPEUI 229 +|(% style="width:305px" %)**Command Example**|(% style="width:186px" %)**Function**|(% style="width:191px" %)**Response** 230 +|(% style="width:305px" %)AT+APPEUI=?|(% style="width:186px" %)Get the Application EUI|(% style="width:191px" %)00 b3 d5 00 00 00 00 00((( 206 206 OK 207 207 ))) 208 -|AT+APPEUI=00 b3 d5 7e f0 00 4d 34|Set the Application EUI|OK 233 +|(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK 209 209 210 210 == 5.2 Application Key == 211 211 212 212 Feature: Get or Set the Application Key. 213 213 214 -AT Command: AT+APPKEY 239 +{{info}} 240 +**AT Command: AT+APPKEY** 241 +{{/info}} 215 215 216 -|=(% colspan="3" %)AT+APPKEY 217 -|**Command Example**|**Function**|**Response** 218 -|AT+APPKEY=?|Get the Application Key|00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35((( 243 +(% style="background-color:#ffffcc; color:green; width:976.222px" %) 244 +|=(% colspan="3" style="width: 973px;" %)AT+APPKEY 245 +|(% style="width:441px" %)**Command Example**|(% style="width:180px" %)**Function**|(% style="width:350px" %)**Response** 246 +|(% style="width:441px" %)AT+APPKEY=?|(% style="width:180px" %)Get the Application Key|(% style="width:350px" %)00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35((( 219 219 OK 220 220 ))) 221 -|AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|Set the Application Key .|OK249 +|(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK 222 222 223 223 == 5.3 Application Session Key == 224 224