<
From version < 59.2 >
edited by Xiaoling
on 2023/01/29 11:16
To version < 51.20 >
edited by Xiaoling
on 2022/07/13 14:19
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -9,12 +9,11 @@
9 9  
10 10  Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
11 11  
12 -* (% style="color:blue" %)**Common Commands:** (%%) They should be available for each sensor, such as: change uplink interval, reset device.
13 -* (% style="color:blue" %)**Sensor Related Commands:** (%%) Only for special sensor, such as control relay, poll RS485 device.
12 +* **Common Commands:** They should be available for each sensor, such as: change uplink interval, reset device.
13 +* **Sensor Related Commands:** Only for special sensor, such as control relay, poll RS485 device.
14 14  
15 15  (((
16 16  **This page shows the common commands since Dragino LoRaWAN stack DR-LWS-005. Make sure the end node support stack higher than DR-LWS-005 before checking this page.**
17 -
18 18  
19 19  )))
20 20  
... ... @@ -21,14 +21,15 @@
21 21  = 2. How to use AT Commands or Downlink command =
22 22  
23 23  
24 -* **AT Command** See Devices User Manual for how to connect to device via USB TTL adapter and use. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
25 -* **LoRaWAN Downlink Command**: The gateway transfer downlink command in HEX format. This page shows the Downlink Command In HEX format. Please note some LoRaWAN servers use base64 as downlink code so user need to convert HEX to Base64 and use. Below are references for how to use downlink command:
23 +* For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
24 +* For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
26 26  ** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
27 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]], [[How to Convert>>http://wiki.dragino.com/xwiki/bin/view/Main/Notes%20for%20ChirpStack/#H4.1ConvertHEXtoBase64]]?
26 +** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
28 28  ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
29 29  
30 30  
31 31  
31 +
32 32  = 3. Support End Node and firmware version =
33 33  
34 34  
... ... @@ -105,8 +105,10 @@
105 105  
106 106  
107 107  
108 +
108 108  = 4. System Management Commands =
109 109  
111 +
110 110  == 4.1 Change Uplink Interval ==
111 111  
112 112  
... ... @@ -136,14 +136,15 @@
136 136  )))
137 137  
138 138  (((
139 -If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
141 +If the downlink payload=0100003C, it means set the END Nodes Transmit Interval to 0x00003C=60(S), while type code is 01.
140 140  )))
141 141  
142 -* **Example 1**: Downlink Payload:** 0100001E**  ~/~/ Set Transmit Interval (TDC) = 30 seconds
143 -* **Example 2**: Downlink Payload:** 0100003C**  ~/~/ Set Transmit Interval (TDC) = 60 seconds
144 +* **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
145 +* **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
144 144  
145 145  
146 146  
149 +
147 147  == 4.2 Reboot End Node ==
148 148  
149 149  
... ... @@ -152,10 +152,10 @@
152 152  
153 153  (% style="color:blue" %)**AT Command: ATZ**
154 154  
155 -(% border="1" style="background-color:#ffffcc; color:green; width:546px" %)
156 -|=(% colspan="3" style="width: 543px;" %)ATZ: Trig a reset of the MCU
157 -|(% style="width:157px" %)**Command Example**|(% style="width:92px" %)**Function**|(% style="width:294px" %)**Response**
158 -|(% style="width:157px" %)ATZ|(% style="width:92px" %)Reset MCU|(% style="width:294px" %)(((
158 +(% border="1" style="background-color:#ffffcc; color:green; width:727.222px" %)
159 +|=(% colspan="3" %)ATZ: Trig a reset of the MCU
160 +|**Command Example**|**Function**|**Response**
161 +|ATZ|Reset MCU|(((
159 159  Device reset and show booting info
160 160  
161 161  LSN50 Device/LoRa ST Module
... ... @@ -189,10 +189,10 @@
189 189  
190 190  (% style="color:blue" %)**AT Command: AT+FDR**
191 191  
192 -(% border="1" style="background-color:#ffffcc; color:green; width:789px" %)
193 -|=(% colspan="3" style="width: 786px;" %)Reset to factory default
194 -|(% style="width:154px" %)**Command Example**|(% style="width:175px" %)**Function**|(% style="width:456px" %)**Response**
195 -|(% style="width:154px" %)AT+FDR|(% style="width:175px" %)Reset to factory default|(% style="width:456px" %)(((
195 +(% border="1" style="background-color:#ffffcc; color:green; width:831.222px" %)
196 +|=(% colspan="3" style="width: 828px;" %)Reset to factory default
197 +|(% style="width:181px" %)**Command Example**|(% style="width:181px" %)**Function**|(% style="width:465px" %)**Response**
198 +|(% style="width:181px" %)AT+FDR|(% style="width:181px" %)Reset to factory default|(% style="width:465px" %)(((
196 196  Device reset to factory default parameters and show booting info
197 197  
198 198  LSN50 Device/LoRa ST Module
... ... @@ -225,10 +225,10 @@
225 225  
226 226  (% style="color:blue" %)**AT Command: AT+VER**
227 227  
228 -(% border="1" style="background-color:#ffffcc; color:green; width:542px" %)
229 -|=(% colspan="3" style="width: 539px;" %)AT+VER: Image Version and Frequency Band
230 -|(% style="width:157px" %)**Command Example**|(% style="width:295px" %)**Function**|(% style="width:86px" %)**Response**
231 -|(% style="width:157px" %)AT+VER=?|(% style="width:295px" %)Show Image version and Frequency Band|(% style="width:86px" %)(((
231 +(% border="1" style="background-color:#ffffcc; color:green; width:586px" %)
232 +|=(% colspan="3" style="width: 583px;" %)AT+VER: Image Version and Frequency Band
233 +|(% style="width:170px" %)**Command Example**|(% style="width:300px" %)**Function**|(% style="width:113px" %)**Response**
234 +|(% style="width:170px" %)AT+VER=?|(% style="width:300px" %)Show Image version and Frequency Band|(% style="width:113px" %)(((
232 232  1.3 EU868
233 233  
234 234  OK
... ... @@ -247,6 +247,7 @@
247 247  (((
248 248  
249 249  
253 +
250 250  **xx: Software Type:**
251 251  )))
252 252  
... ... @@ -309,6 +309,7 @@
309 309  
310 310  = 5. Keys, IDs and EUIs management =
311 311  
316 +
312 312  == 5.1 Application EUI ==
313 313  
314 314  
... ... @@ -443,8 +443,10 @@
443 443  
444 444  = 6. Joining and sending date on LoRaWAN network =
445 445  
451 +
446 446  == 6.1 Confirm Mode ==
447 447  
454 +
448 448  === 6.1.1  AT+CFM command before DR-LWS007 software stack ===
449 449  
450 450  
... ... @@ -468,11 +468,12 @@
468 468  
469 469  If the downlink payload=0501, it means set end node to use confirm mode, while type code is 05.
470 470  
471 -* **Example 1:** Downlink Payload: 0501  ~/~/ Set AT+CFM=1
472 -* **Example 2:** Downlink Payload: 0500  ~/~/ Set AT+CFM=0
478 +* Example 1: Downlink Payload: 0501 ~/~/ Set AT+CFM=1
479 +* Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0
473 473  
474 474  
475 475  
483 +
476 476  === 6.1.2  AT+CFM command since DR-LWS007 software stack ===
477 477  
478 478  
... ... @@ -515,11 +515,12 @@
515 515  
516 516  If the downlink payload=05010101, it means set end node to use confirm mode, while type code is 05.
517 517  
518 -* **Example 1:** Downlink Payload: 05010101  ~/~/ Set AT+CFM=1,1,1
519 -* **Example 2:** Downlink Payload: 05000700  ~/~/ Set AT+CFM=0,7,0
526 +* Example 1: Downlink Payload: 05010101 ~/~/ Set AT+CFM=1,1,1
527 +* Example 2: Downlink Payload: 05000700 ~/~/ Set AT+CFM=0,7,0
520 520  
521 521  
522 522  
531 +
523 523  == 6.2 Confirm Status ==
524 524  
525 525  
... ... @@ -528,10 +528,10 @@
528 528  
529 529  (% style="color:blue" %)**AT Command: AT+CFS**
530 530  
531 -(% border="1" style="background-color:#ffffcc; color:green; width:463px" %)
532 -|=(% colspan="3" style="width: 460px;" %)AT+CFS
533 -|(% style="width:156px" %)**Command Example**|(% style="width:193px" %)**Function**|(% style="width:107px" %)**Response**
534 -|(% style="width:156px" %)AT+CFS=?|(% style="width:193px" %)Get confirmation status|(% style="width:107px" %)0(((
540 +(% border="1" style="background-color:#ffffcc; color:green; width:534.222px" %)
541 +|=(% colspan="3" style="width: 531px;" %)AT+CFS
542 +|(% style="width:156px" %)**Command Example**|(% style="width:193px" %)**Function**|(% style="width:178px" %)**Response**
543 +|(% style="width:156px" %)AT+CFS=?|(% style="width:193px" %)Get confirmation status|(% style="width:178px" %)0(((
535 535  OK
536 536  )))
537 537  
... ... @@ -579,11 +579,12 @@
579 579  
580 580  If the downlink payload=2000, it means set the Network Join Mode, while type code is 20.
581 581  
582 -* **Example 1: **Downlink Payload: **2000                  ** ~/~/ Set AT+NJM=0
583 -* **Example 2:** Downlink Payload: **2001**  ~/~/ Set AT+NJM=1
591 +* **Example 1: **Downlink Payload: **2000** ~/~/ Set AT+NJM=0
592 +* **Example 2:** Downlink Payload: **2001** ~/~/ Set AT+NJM=1
584 584  
585 585  
586 586  
596 +
587 587  == 6.5 LoRa® Network Join Status ==
588 588  
589 589  
... ... @@ -664,11 +664,11 @@
664 664  
665 665  (% style="color:blue" %)**AT Command: AT+SENDB**
666 666  
667 -(% border="1" style="background-color:#ffffcc; color:green; width:1101px" %)
668 -|=(% colspan="3" style="width: 1098px;" %)AT+SENDB
669 -|(% style="width:257px" %)**Command Example**|(% style="width:394px" %)**Function**|(% style="width:446px" %)**Response**
670 -|(% style="width:257px" %)AT+SENDB=12:abcdef0123456789|(% style="width:394px" %)Send hexadecimal data along with the application port.|(% style="width:446px" %)OK
671 -|(% style="width:257px" %)AT+SENDB=abcdef0123456789|(% style="width:394px" %)Send hexadecimal data along with the application port.|(% style="width:446px" %)While Error in format, return(((
677 +(% border="1" style="background-color:#ffffcc; color:green; width:1120.22px" %)
678 +|=(% colspan="3" style="width: 1117px;" %)AT+SENDB
679 +|(% style="width:257px" %)**Command Example**|(% style="width:406px" %)**Function**|(% style="width:453px" %)**Response**
680 +|(% style="width:257px" %)AT+SENDB=12:abcdef0123456789|(% style="width:406px" %)Send hexadecimal data along with the application port.|(% style="width:453px" %)OK
681 +|(% style="width:257px" %)AT+SENDB=abcdef0123456789|(% style="width:406px" %)Send hexadecimal data along with the application port.|(% style="width:453px" %)While Error in format, return(((
672 672  AT_PARAM_ERROR AT_BUSY_ERROR/AT_NO_NETWORK_JOINED
673 673  
674 674  
... ... @@ -678,6 +678,7 @@
678 678  
679 679  = 7. LoRaWAN network management =
680 680  
691 +
681 681  == 7.1 Adaptive Data Rate ==
682 682  
683 683  
... ... @@ -697,15 +697,17 @@
697 697  AT_PARAM_ERROR
698 698  )))
699 699  
711 +
700 700  (% style="color:blue" %)**Downlink Command: 0x22**
701 701  
702 702  If the downlink payload=2201, it means setting the adaptive data rate to 1, while type code is 22.
703 703  
704 -* **Example 1**: Downlink Payload: **2201**  ~/~/ Set AT+ADR=1.
705 -* **Example 2**: Downlink Payload: **2200FFFF**  ~/~/ Set AT+ADR=0.
716 +* **Example 1**: Downlink Payload: **2201**  ~/~/ Set AT+ADR=1.
717 +* **Example 2**: Downlink Payload: **2200FFFF** ~/~/ Set AT+ADR=0.
706 706  
707 707  
708 708  
721 +
709 709  == 7.2 LoRa® Class ==
710 710  
711 711  
... ... @@ -712,7 +712,7 @@
712 712  Feature: Get or Set the Device Class(Currently only support class A, class C).
713 713  
714 714  
715 -(% style="color:blue" %)**AT Command:  AT+CLASS**
728 +(% style="color:blue" %)**AT Command:AT+CLASS**
716 716  
717 717  (% border="1" style="background-color:#ffffcc; color:green; width:507.222px" %)
718 718  |=(% colspan="3" style="width: 504px;" %)AT+CLASS
... ... @@ -729,10 +729,10 @@
729 729  == 7.3 Duty Cycle Setting ==
730 730  
731 731  
732 -Feature: Get or Set the ETSI Duty Cycle setting** - 0**=disable, **1**=enable - Only for testing.
745 +Feature: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing.
733 733  
734 734  
735 -(% style="color:blue" %)**AT Command:  AT+DCS**
748 +(% style="color:blue" %)**AT Command:AT+DCS**
736 736  
737 737  (% border="1" style="background-color:#ffffcc; color:green; width:515.222px" %)
738 738  |=(% colspan="3" style="width: 512px;" %)AT+DCS
... ... @@ -749,14 +749,9 @@
749 749  == 7.4 Data Rate ==
750 750  
751 751  
752 -Feature: Get or Set the Data Rate. (0-7 corresponding to DR_X) .
765 +Feature: Get or Set the Data Rate. (0-7 corresponding to DR_X) . Note: while set Data Rate, please use set Adptive Data Rate, ADR=0 first. otherwise device will response to server's ADR command and change the DR to the setting from server
753 753  
754 -(% style="color:red" %)
755 -**Notice:**
756 756  
757 -* User need to set Adaptive Data Rate(ADR)=0 first. otherwise device will respond to server's ADR command and change the DR according to server auto-adjustment.
758 -* Data Rate specifies Spreading Factor. The mapping varies in different frequency bands. User can check this link for detail. [[rp2-1.0.3-lorawan-regional-parameters.pdf>>https://lora-alliance.org/resource_hub/rp2-1-0-3-lorawan-regional-parameters/]]
759 -
760 760  (% style="color:blue" %)**AT Command: AT+DR**
761 761  
762 762  (% border="1" style="background-color:#ffffcc; color:green; width:466.222px" %)
... ... @@ -769,15 +769,17 @@
769 769  
770 770  )))
771 771  
780 +
772 772  (% style="color:blue" %)**Downlink Command: 0x2200aaFF**
773 773  
774 774  If the downlink payload=220001FF, it means setting the data rate to 1, while type code is 22 00 aa FF.
775 775  
776 -* **Example 1**: Downlink Payload: **220001FF**  ~/~/ Set AT+DR=1.
777 -* **Example 2**: Downlink Payload: **220000FF**  ~/~/ Set AT+DR=0.
785 +* **Example 1**: Downlink Payload: **220001FF** ~/~/ Set AT+DR=1.
786 +* **Example 2**: Downlink Payload: **220000FF** ~/~/ Set AT+DR=0.
778 778  
779 779  
780 780  
790 +
781 781  == 7.5 Frame Counter Downlink ==
782 782  
783 783  
... ... @@ -784,7 +784,7 @@
784 784  Feature: Get or Set the Frame Counter Downlink.
785 785  
786 786  
787 -(% style="color:blue" %)**AT Command:  AT+FCD**
797 +(% style="color:blue" %)**AT Command:AT+FCD**
788 788  
789 789  (% border="1" style="background-color:#ffffcc; color:green; width:693.222px" %)
790 790  |=(% colspan="3" style="width: 690px;" %)AT+FCD
... ... @@ -803,7 +803,7 @@
803 803  Feature: Get or Set the Frame Counter Uplink.
804 804  
805 805  
806 -(% style="color:blue" %)**AT Command:  AT+FCU**
816 +(% style="color:blue" %)**AT Command:AT+FCU**
807 807  
808 808  (% border="1" style="background-color:#ffffcc; color:green; width:534.222px" %)
809 809  |=(% colspan="3" style="width: 531px;" %)AT+FCU
... ... @@ -823,7 +823,7 @@
823 823  Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms.
824 824  
825 825  
826 -(% style="color:blue" %)**AT Command:  AT+JN1DL**
836 +(% style="color:blue" %)**AT Command:AT+JN1DL**
827 827  
828 828  (% border="1" style="background-color:#ffffcc; color:green; width:537.222px" %)
829 829  |=(% colspan="3" style="width: 534px;" %)AT+JN1DL
... ... @@ -839,11 +839,10 @@
839 839  
840 840  == 7.8 Join Accept Delay2 ==
841 841  
842 -
843 843  Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms.
844 844  
845 845  
846 -(% style="color:blue" %)**AT Command:  AT+JN2DL**
855 +(% style="color:blue" %)**AT Command:AT+JN2DL**
847 847  
848 848  (% border="1" style="background-color:#ffffcc; color:green; width:538.222px" %)
849 849  |=(% colspan="3" style="width: 535px;" %)AT+JN2DL
... ... @@ -862,10 +862,10 @@
862 862  
863 863  Feature: Get or Set the public network mode. (0: off, 1: on). A Public LoRaWAN network use 0x34 as syncword. Default Settings; PNM=1
864 864  
865 -(% style="color:red" %)**Notice: If user build their own LoRaWAN server but still use syncword=0x34, this is still considered a public LoRaWAN network.**
874 +(% style="color:red" %)Notice: If user build their own LoRaWAN server but still use syncword=0x34, this is still considered a public LoRaWAN network
866 866  
867 867  
868 -(% style="color:blue" %)**AT Command:  AT+PNM**
877 +(% style="color:blue" %)**AT Command:AT+PNM**
869 869  
870 870  (% border="1" style="background-color:#ffffcc; color:green; width:667.222px" %)
871 871  |=(% colspan="3" style="width: 664px;" %)AT+PNM
... ... @@ -892,7 +892,7 @@
892 892  Feature: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms
893 893  
894 894  
895 -(% style="color:blue" %)**AT Command: AT+RX1DL**
904 +(% style="color:blue" %)**AT Command:AT+RX1DL**
896 896  
897 897  (% border="1" style="background-color:#ffffcc; color:green; width:408.222px" %)
898 898  |=(% colspan="3" style="width: 405px;" %)AT+RX1DL
... ... @@ -912,7 +912,7 @@
912 912  Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
913 913  
914 914  
915 -(% style="color:blue" %)**AT Command: AT+RX2DL**
924 +(% style="color:blue" %)**AT Command:AT+RX2DL**
916 916  
917 917  (% border="1" style="background-color:#ffffcc; color:green; width:481.222px" %)
918 918  |=(% colspan="3" style="width: 478px;" %)AT+RX2DL
... ... @@ -932,7 +932,7 @@
932 932  Feature: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X)
933 933  
934 934  
935 -(% style="color:blue" %)**AT Command:  AT+RX2DR**
944 +(% style="color:blue" %)**AT Command:AT+RX2DR**
936 936  
937 937  (% border="1" style="background-color:#ffffcc; color:green; width:525.222px" %)
938 938  |=(% colspan="3" style="width: 522px;" %)AT+RX2DR
... ... @@ -952,7 +952,7 @@
952 952  Feature: Get or Set the Rx2 window frequency
953 953  
954 954  
955 -(% style="color:blue" %)**AT Command:  AT+RX2FQ**
964 +(% style="color:blue" %)**AT Command:AT+RX2FQ**
956 956  
957 957  (% border="1" style="background-color:#ffffcc; color:green; width:587.222px" %)
958 958  |=(% colspan="3" style="width: 584px;" %)AT+RX2FQ
... ... @@ -971,11 +971,9 @@
971 971  
972 972  Feature: Get or Set the Transmit Power(0-5, MAX:0, MIN:5, according to LoRaWAN Spec, or 40=10dB, 41 = 11dB, …, 50 = 20dB which is out of LoRaWAN spec. )
973 973  
974 -(% style="color:red" %)**Notice: Transmit Power might be changed by ADR from LoRaWAN server. So manually change TXP also remember to set AT+ADR=0 in sensor**
975 975  
984 +(% style="color:blue" %)**AT Command:AT+TXP**
976 976  
977 -(% style="color:blue" %)**AT Command:  AT+TXP**
978 -
979 979  (% border="1" style="background-color:#ffffcc; color:green; width:465.222px" %)
980 980  |=(% colspan="3" style="width: 462px;" %)AT+TXP
981 981  |(% style="width:161px" %)**Command Example**|(% style="width:189px" %)**Function**|(% style="width:112px" %)**Response**
... ... @@ -986,15 +986,17 @@
986 986  
987 987  )))
988 988  
996 +
989 989  Downlink Payload. The 4th byte of 0x22 downlink.
990 990  
991 991  If the downlink payload=22000100, it means setting the TXP to 0.
992 992  
993 -* **Example 1**: Downlink Payload: **22000102**  ~/~/ Set AT+TXP=2.
994 -* **Example 2**: Downlink Payload: **220000FF**  ~/~/ Set AT+TXP=0.
1001 +* **Example 1**: Downlink Payload: **22000102** ~/~/ Set AT+TXP=2.
1002 +* **Example 2**: Downlink Payload: **220000FF** ~/~/ Set AT+TXP=0.
995 995  
996 996  
997 997  
1006 +
998 998  == 7.15 RSSI of the Last Received Packet ==
999 999  
1000 1000  
... ... @@ -1018,7 +1018,7 @@
1018 1018  Feature: Get the SNR of the last received packet
1019 1019  
1020 1020  
1021 -(% style="color:blue" %)**AT Command:  AT+SNR**
1030 +(% style="color:blue" %)**AT Command:AT+SNR**
1022 1022  
1023 1023  (% border="1" style="background-color:#ffffcc; color:green; width:571.222px" %)
1024 1024  |=(% colspan="3" style="width: 568px;" %)AT+SNR
... ... @@ -1045,6 +1045,7 @@
1045 1045  )))
1046 1046  |(% style="width:157px" %)AT+PORT=21|(% style="width:204px" %)Set the application port|(% style="width:135px" %)OK
1047 1047  
1057 +
1048 1048  (% style="color:blue" %)**Downlink Command: 0x23**
1049 1049  
1050 1050  Format: Command Code (0x23) followed by 1 bytes port value.
... ... @@ -1051,8 +1051,8 @@
1051 1051  
1052 1052  If the downlink payload=2301, it means set the application port to 1, while type code is 23.
1053 1053  
1054 -* **Example 1**: Downlink Payload: **2301**  ~/~/ set the application port to 1
1055 -* **Example 2**: Downlink Payload:** 2305**  ~/~/ set the application port to 5
1064 +* **Example 1**: Downlink Payload: **2301** ~/~/ set the application port to 1
1065 +* **Example 2**: Downlink Payload:** 2305** ~/~/ set the application port to 5
1056 1056  
1057 1057  
1058 1058  
... ... @@ -1076,7 +1076,6 @@
1076 1076  
1077 1077  == 7.19 Eight Channel Mode ==
1078 1078  
1079 -
1080 1080  Feature: Get or Set eight channels mode,Only for US915,AU915,CN470.
1081 1081  
1082 1082  
... ... @@ -1092,17 +1092,19 @@
1092 1092  )))
1093 1093  |(% style="width:160px" %)AT+CHE=1|(% style="width:198px" %)Set eight channels mode|(% style="width:349px" %)OK
1094 1094  
1095 -(% style="color:blue" %)**Downlink Command: 0x24 (LHT65,LHT65N Downlink Command:0x07)**
1096 1096  
1105 +(% style="color:blue" %)**Downlink Command: 0x24**
1106 +
1097 1097  Format: Command Code (0x24) followed by 1 bytes channel value.
1098 1098  
1099 1099  If the downlink payload=2401, it means set channel mode to 1, while type code is 24.
1100 1100  
1101 -* **Example 1**: Downlink Payload: 2401  ~/~/ set channel mode to 1
1102 -* **Example 2**: Downlink Payload: 2405  ~/~/ set channel mode to 5
1111 +* **Example 1**: Downlink Payload: 2401 ~/~/ set channel mode to 1
1112 +* **Example 2**: Downlink Payload: 2405 ~/~/ set channel mode to 5
1103 1103  
1104 1104  
1105 1105  
1116 +
1106 1106  == 7.20 Get or Set RXwindows1 timeout ==
1107 1107  
1108 1108  
... ... @@ -1122,9 +1122,8 @@
1122 1122  (((
1123 1123  
1124 1124  
1136 +**AT+RX1TWO** is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph.
1125 1125  
1126 -(% style="color:blue" %)**AT+RX1WTO**(%%) is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph.
1127 -
1128 1128  
1129 1129  )))
1130 1130  
... ... @@ -1171,6 +1171,7 @@
1171 1171  )))
1172 1172  |(% style="width:183px" %)AT+DWELLT=0|(% style="width:179px" %)Set uplinkdwelltime|(% style="width:131px" %)OK
1173 1173  
1184 +
1174 1174  (% style="color:blue" %)**Downlink Command: 0x25**
1175 1175  
1176 1176  Format: Command Code (0x25) followed by 1 bytes state value.
... ... @@ -1177,11 +1177,12 @@
1177 1177  
1178 1178  If the downlink payload=2501, it means set uplinkdwelltime to 1, while type code is 25.
1179 1179  
1180 -* **Example 1**: Downlink Payload: **2501**  ~/~/ set uplinkdwelltime to 1
1181 -* **Example 2**: Downlink Payload: **2500**  ~/~/ set uplinkdwelltime to 0
1191 +* **Example 1**: Downlink Payload: **2501** ~/~/ set uplinkdwelltime to 1
1192 +* **Example 2**: Downlink Payload: **2500** ~/~/ set uplinkdwelltime to 0
1182 1182  
1183 1183  
1184 1184  
1196 +
1185 1185  == 7.23 Set Packet Receiving Response Level ==
1186 1186  
1187 1187  
... ... @@ -1196,6 +1196,7 @@
1196 1196  * **AT+RPL=3:** Device will immediately reply message to MAC Command. Payload is 0x00 and requied response header for this command.
1197 1197  * **AT+RPL=4: **Device will immediately reply message to Confirmed Data Down & MAC Command. Payload is 0x00 and requied response header for these two commands.
1198 1198  
1211 +
1199 1199  **Case Analyes:**
1200 1200  
1201 1201  * For Class A devices, AT+RPL=0 is ok. that is defaut settings in software.
... ... @@ -1202,6 +1202,7 @@
1202 1202  * For Class C devices used in ChirpStack, need to set AT+RPL=4 because Chirpstack require immedietely reply message to MAC Command.
1203 1203  * For Class C devices used in TTI, need to set AT+RPL=4 because TTI require immediately reply message to Confirmed Data Down & MAC Command.
1204 1204  
1218 +
1205 1205  (% style="color:blue" %)**AT Command: AT+RPL**
1206 1206  
1207 1207  (% border="1" style="background-color:#ffffcc; color:green; width:536.222px" %)
... ... @@ -1212,6 +1212,7 @@
1212 1212  )))
1213 1213  |(% style="width:160px" %)AT+RPL=0|(% style="width:263px" %)Set packet receiving response level|(% style="width:109px" %)OK
1214 1214  
1229 +
1215 1215  (% style="color:blue" %)**Downlink Command: 0x21**
1216 1216  
1217 1217  Format: Command Code (0x21) followed by 1 bytes level value.
... ... @@ -1218,32 +1218,30 @@
1218 1218  
1219 1219  If the downlink payload=2101, it means set packet receiving response level to 1, while type code is 21.
1220 1220  
1221 -* **Example 1**: Downlink Payload: **2101**  ~/~/ set packet receiving response level to 1
1222 -* **Example 2**: Downlink Payload: **2102**  ~/~/ set packet receiving response level to 2
1236 +* **Example 1**: Downlink Payload: **2101** ~/~/ set packet receiving response level to 1
1237 +* **Example 2**: Downlink Payload: **2102** ~/~/ set packet receiving response level to 2
1223 1223  
1224 1224  
1225 1225  
1241 +
1226 1226  == 7.24 Controls NBTrans in unconfirmed uplink mode(LWS007 NBTrans:Set retransmission packets) ==
1227 1227  
1228 1228  
1229 1229  (% style="color:blue" %)**AT Command: AT+SETMAXNBTRANS **
1230 1230  
1231 -(% border="1" style="background-color:#ffffcc; color:green; width:589px" %)
1232 -|=(% colspan="3" style="width: 586px;" %)AT+**SETMAXNBTRANS**
1233 -|(% style="width:227px" %)**Command Example**|(% style="width:300px" %)**Function**|(% style="width:87px" %)**Response**
1234 -|(% style="width:227px" %)**AT+SETMAXNBTRANS=1,0**|(% style="width:300px" %)Value1: set the maximum NBTrans.|(% style="width:87px" %)1(((
1247 +(% border="1" style="background-color:#ffffcc; color:green; width:536.222px" %)
1248 +|=(% colspan="3" style="width: 533px;" %)AT+**SETMAXNBTRANS**
1249 +|(% style="width:160px" %)**Command Example**|(% style="width:263px" %)**Function**|(% style="width:109px" %)**Response**
1250 +|(% style="width:160px" %)**AT+SETMAXNBTRANS=1,0**|(% style="width:263px" %)Value1: set the maximum NBTrans.|(% style="width:109px" %)1(((
1235 1235  OK
1236 1236  )))
1237 -|(% style="width:227px" %)**AT+SETMAXNBTRANS=?,1**|(% style="width:300px" %)(((
1238 -value2: 0: uplink fcnt doesn't change for each NBTrans;
1239 -
1240 -1: uplink fcnt increase by 1 for each NBTrans.
1241 -)))|(% style="width:87px" %)(((
1253 +|(% style="width:160px" %)**AT+SETMAXNBTRANS=?,1**|(% style="width:263px" %)value2: 0: uplink fcnt doesn't change for each NBTrans; 1: uplink fcnt increase by 1 for each NBTrans.|(% style="width:109px" %)(((
1242 1242  1
1243 1243  
1244 1244  OK
1245 1245  )))
1246 1246  
1259 +
1247 1247  (% style="color:blue" %)**Downlink Command: 0x33**
1248 1248  
1249 1249  Format: Command Code (0x33) followed by 2 bytes mode value.
... ... @@ -1250,8 +1250,8 @@
1250 1250  
1251 1251  If the downlink payload=330100, it means set end node to use confirm mode, while type code is 33.
1252 1252  
1253 -* Example 1: Downlink Payload: 330100  ~/~/ Set AT+SETMAXNBTRANS=1,0
1254 -* Example 2: Downlink Payload: 330201  ~/~/ Set AT+SETMAXNBTRANS=2,1
1266 +* Example 1: Downlink Payload: 330100 ~/~/ Set AT+SETMAXNBTRANS=1,0
1267 +* Example 2: Downlink Payload: 330201 ~/~/ Set AT+SETMAXNBTRANS=2,1
1255 1255  
1256 1256  
1257 1257  
... ... @@ -1291,6 +1291,7 @@
1291 1291  OK
1292 1292  )))
1293 1293  
1307 +
1294 1294  (% style="color:blue" %)**Downlink Command: 0x33**
1295 1295  
1296 1296  Format: Command Code (0x32) followed by 2 bytes mode value.
... ... @@ -1297,7 +1297,7 @@
1297 1297  
1298 1298  If the downlink payload=320105A00B40, it means set end node to use confirm mode, while type code is 33.
1299 1299  
1300 -* **Example 1:** Downlink Payload: 320105A00B40  ~/~/ Set AT+DDETECT=1,1440,2880
1314 +* Example 1: Downlink Payload: 320105A00B40 ~/~/ Set AT+DDETECT=1,1440,2880
1301 1301  
1302 1302  
1303 1303  
... ... @@ -1328,15 +1328,16 @@
1328 1328  (% border="1" style="background-color:#ffffcc; color:green; width:727.222px" %)
1329 1329  |=(% colspan="3" style="width: 724px;" %)AT+RJTDC
1330 1330  |(% style="width:165px" %)**Command Example**|(% style="width:227px" %)**Function**|(% style="width:329px" %)**Response**
1331 -|(% style="width:165px" %)AT+RJTDC=?|(% style="width:227px" %)Show the ReJoin data transmission interval in min|(% style="width:329px" %)30(((
1345 +|(% style="width:165px" %)AT+RJTDC=?|(% style="width:227px" %)Show the ReJoin data transmission interval in min|(% style="width:329px" %)30000(((
1332 1332  OK
1333 1333  
1334 -the interval is 30 min
1348 +the interval is 30000ms = 30s
1335 1335  )))
1336 -|(% style="width:165px" %)AT+RJTDC=60|(% style="width:227px" %)Set the ReJoin data transmission interval in min|(% style="width:329px" %)OK(((
1337 -Set the ReJoin data transmission interval to 60 min
1350 +|(% style="width:165px" %)AT+RJTDC=60000|(% style="width:227px" %)Set the ReJoin data transmission interval in min|(% style="width:329px" %)OK(((
1351 +Set the ReJoin data transmission interval to 60000ms = 60 seconds
1338 1338  )))
1339 1339  
1354 +
1340 1340  (% style="color:blue" %)**Downlink Command: 0x26**
1341 1341  
1342 1342  Format: Command Code (0x26) followed by 2 bytes mode value.
... ... @@ -1343,18 +1343,19 @@
1343 1343  
1344 1344  If the downlink payload=26000A, it means set end node to use confirm mode, while type code is 26.
1345 1345  
1346 -* **Example 1:** Downlink Payload: 26000A  ~/~/ Set AT+RJTDC=10
1347 -* **Example 2: **Downlink Payload: 260002  ~/~/ Set AT+RJTDC=2
1361 +* Example 1: Downlink Payload: 26000A ~/~/ Set AT+RJTDC=10
1362 +* Example 2: Downlink Payload: 260002 ~/~/ Set AT+RJTDC=2
1348 1348  
1349 1349  
1350 1350  
1351 1351  = 8. AT Commands Combination =
1352 1352  
1368 +
1353 1353  == 8.1 Set a fix RX2DR for downlink window ==
1354 1354  
1355 1355  
1356 -* (% style="color:blue" %)**AT+ADR=0             **(%%) **~-~->**  Disable ADR first
1357 -* (% style="color:blue" %)**AT+RX2DR=xxxx**   (%%) **~-~->**  Set xxxx to your wanted DataRate
1372 +* **AT+ADR=0             ** **~-~->**  Disable ADR first
1373 +* **AT+RX2DR=xxxx**  **~-~->**  Set xxxx to your wanted DataRate
1358 1358  
1359 1359  
1360 1360  
... ... @@ -1365,8 +1365,6 @@
1365 1365  
1366 1366  **Same as:**
1367 1367  
1368 -* AT+ADR=0  [[Reference>>||anchor="H7.1AdaptiveDataRate"]]
1369 -* AT+DR=5  [[Reference>>||anchor="H7.4DataRate"]]
1370 -* AT+TXP=0  [[Reference>>||anchor="H7.14TransmitPower"]]
1371 -
1372 -
1384 +* AT+ADR=0  [[Reference>>||anchor="H7.1AdaptiveDataRate"]]
1385 +* AT+DR=5  [[Reference>>||anchor="H7.4DataRate"]]
1386 +* AT+TXP=0  [[Reference>>||anchor="H7.14TransmitPower"]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0