Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,14 +9,12 @@ 9 9 10 10 Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands: 11 11 12 -* (% style="color:blue" %)**Common Commands:**(%%)They should be available for each sensor, such as: change uplink interval, reset device.13 -* (% style="color:blue" %)**Sensor Related Commands:**(%%)Only for special sensor, such as control relay, poll RS485 device.12 +* **Common Commands:** They should be available for each sensor, such as: change uplink interval, reset device. 13 +* **Sensor Related Commands:** Only for special sensor, such as control relay, poll RS485 device. 14 14 15 15 ((( 16 16 **This page shows the common commands since Dragino LoRaWAN stack DR-LWS-005. Make sure the end node support stack higher than DR-LWS-005 before checking this page.** 17 17 18 - 19 - 20 20 ))) 21 21 22 22 = 2. How to use AT Commands or Downlink command = ... ... @@ -25,7 +25,7 @@ 25 25 * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]] 26 26 * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command: 27 27 ** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]] 28 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]] , [[How to Convert>>http://wiki.dragino.com/xwiki/bin/view/Main/Notes%20for%20ChirpStack/#H4.1ConvertHEXtoBase64]]?26 +** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]] 29 29 ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server) 30 30 31 31 ... ... @@ -110,6 +110,7 @@ 110 110 111 111 = 4. System Management Commands = 112 112 111 + 113 113 == 4.1 Change Uplink Interval == 114 114 115 115 ... ... @@ -139,7 +139,7 @@ 139 139 ))) 140 140 141 141 ((( 142 -If the downlink payload=0100003C, it means set the END Node 's Transmit Interval to 0x00003C=60(S), while type code is 01.141 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 143 143 ))) 144 144 145 145 * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds ... ... @@ -156,10 +156,10 @@ 156 156 157 157 (% style="color:blue" %)**AT Command: ATZ** 158 158 159 -(% border="1" style="background-color:#ffffcc; color:green; width: 546px" %)160 -|=(% colspan="3" style="width: 543px;"%)ATZ: Trig a reset of the MCU161 -| (% style="width:157px" %)**Command Example**|(% style="width:92px" %)**Function**|(% style="width:294px" %)**Response**162 -| (% style="width:157px" %)ATZ|(% style="width:92px" %)Reset MCU|(% style="width:294px" %)(((158 +(% border="1" style="background-color:#ffffcc; color:green; width:727.222px" %) 159 +|=(% colspan="3" %)ATZ: Trig a reset of the MCU 160 +|**Command Example**|**Function**|**Response** 161 +|ATZ|Reset MCU|((( 163 163 Device reset and show booting info 164 164 165 165 LSN50 Device/LoRa ST Module ... ... @@ -173,6 +173,7 @@ 173 173 <followed by the Tx and Rx information> 174 174 ))) 175 175 175 + 176 176 (% style="color:blue" %)**Downlink Command: 0x04** 177 177 178 178 ((( ... ... @@ -182,7 +182,6 @@ 182 182 ((( 183 183 If the downlink payload=**04FF**, the end node will reboot. 184 184 185 - 186 186 187 187 ))) 188 188 ... ... @@ -194,10 +194,10 @@ 194 194 195 195 (% style="color:blue" %)**AT Command: AT+FDR** 196 196 197 -(% border="1" style="background-color:#ffffcc; color:green; width: 789px" %)198 -|=(% colspan="3" style="width: 786px;" %)Reset to factory default199 -|(% style="width:1 54px" %)**Command Example**|(% style="width:175px" %)**Function**|(% style="width:456px" %)**Response**200 -|(% style="width:1 54px" %)AT+FDR|(% style="width:175px" %)Reset to factory default|(% style="width:456px" %)(((196 +(% border="1" style="background-color:#ffffcc; color:green; width:831.222px" %) 197 +|=(% colspan="3" style="width: 828px;" %)Reset to factory default 198 +|(% style="width:181px" %)**Command Example**|(% style="width:181px" %)**Function**|(% style="width:465px" %)**Response** 199 +|(% style="width:181px" %)AT+FDR|(% style="width:181px" %)Reset to factory default|(% style="width:465px" %)((( 201 201 Device reset to factory default parameters and show booting info 202 202 203 203 LSN50 Device/LoRa ST Module ... ... @@ -211,6 +211,7 @@ 211 211 Please set the parameters or reset Device to apply change 212 212 ))) 213 213 213 + 214 214 (% style="color:blue" %)**Downlink Command: 0x04** 215 215 216 216 ((( ... ... @@ -222,7 +222,6 @@ 222 222 ))) 223 223 224 224 225 - 226 226 == 4.4 Show Firmware Version == 227 227 228 228 ... ... @@ -231,15 +231,16 @@ 231 231 232 232 (% style="color:blue" %)**AT Command: AT+VER** 233 233 234 -(% border="1" style="background-color:#ffffcc; color:green; width:5 42px" %)235 -|=(% colspan="3" style="width: 53 9px;" %)AT+VER: Image Version and Frequency Band236 -|(% style="width:1 57px" %)**Command Example**|(% style="width:295px" %)**Function**|(% style="width:86px" %)**Response**237 -|(% style="width:1 57px" %)AT+VER=?|(% style="width:295px" %)Show Image version and Frequency Band|(% style="width:86px" %)(((233 +(% border="1" style="background-color:#ffffcc; color:green; width:586px" %) 234 +|=(% colspan="3" style="width: 583px;" %)AT+VER: Image Version and Frequency Band 235 +|(% style="width:170px" %)**Command Example**|(% style="width:300px" %)**Function**|(% style="width:113px" %)**Response** 236 +|(% style="width:170px" %)AT+VER=?|(% style="width:300px" %)Show Image version and Frequency Band|(% style="width:113px" %)((( 238 238 1.3 EU868 239 239 240 240 OK 241 241 ))) 242 242 242 + 243 243 (% style="color:blue" %)**Downlink Command: 0x26 (Valid in 006 stack)** 244 244 245 245 ((( ... ... @@ -287,7 +287,6 @@ 287 287 firmware version: v1.1.0 ~-~-> 110 288 288 289 289 290 - 291 291 == 4.5 Show System Configure == 292 292 293 293 ... ... @@ -315,9 +315,9 @@ 315 315 316 316 317 317 318 - 319 319 = 5. Keys, IDs and EUIs management = 320 320 319 + 321 321 == 5.1 Application EUI == 322 322 323 323 ... ... @@ -336,7 +336,6 @@ 336 336 337 337 338 338 339 - 340 340 == 5.2 Application Key == 341 341 342 342 ... ... @@ -355,7 +355,6 @@ 355 355 356 356 357 357 358 - 359 359 == 5.3 Application Session Key == 360 360 361 361 ... ... @@ -376,7 +376,6 @@ 376 376 377 377 378 378 379 - 380 380 == 5.4 Device Address == 381 381 382 382 ... ... @@ -397,7 +397,6 @@ 397 397 398 398 399 399 400 - 401 401 == 5.5 Device EUI == 402 402 403 403 ... ... @@ -418,7 +418,6 @@ 418 418 419 419 420 420 421 - 422 422 == 5.6 Network ID == 423 423 424 424 ... ... @@ -437,7 +437,6 @@ 437 437 438 438 439 439 440 - 441 441 == 5.7 Network Session Key == 442 442 443 443 ... ... @@ -456,11 +456,12 @@ 456 456 457 457 458 458 459 - 460 460 = 6. Joining and sending date on LoRaWAN network = 461 461 454 + 462 462 == 6.1 Confirm Mode == 463 463 457 + 464 464 === 6.1.1 AT+CFM command before DR-LWS007 software stack === 465 465 466 466 ... ... @@ -478,6 +478,7 @@ 478 478 |(% style="width:155px" %)AT+CFM=1|(% style="width:205px" %)Set the confirmation mode|(% style="width:346px" %)OK 479 479 |(% style="width:155px" %)AT+CFM=2|(% style="width:205px" %)Set the confirmation mode|(% style="width:346px" %)While Error in format, return AT_PARAM_ERROR 480 480 475 + 481 481 (% style="color:blue" %)**Downlink Command: 0x05** 482 482 483 483 Format: Command Code (0x05) followed by 2 bytes mode value. ... ... @@ -526,6 +526,7 @@ 526 526 OK 527 527 ))) 528 528 524 + 529 529 (% style="color:blue" %)**Downlink Command: 0x05** 530 530 531 531 Format: Command Code (0x05) followed by 2 bytes mode value. ... ... @@ -555,7 +555,6 @@ 555 555 556 556 557 557 558 - 559 559 == 6.3 Join LoRa® Network == 560 560 561 561 ... ... @@ -575,7 +575,6 @@ 575 575 576 576 577 577 578 - 579 579 == 6.4 LoRa® Network Join Mode == 580 580 581 581 ... ... @@ -593,6 +593,7 @@ 593 593 |(% style="width:162px" %)AT+NJM=0|(% style="width:227px" %)Set the Network Join Mode|(% style="width:361px" %)OK 594 594 |(% style="width:162px" %)AT+NJM=2|(% style="width:227px" %)Set the Network Join Mode|(% style="width:361px" %)While Error in format, return AT_PARAM_ERROR 595 595 590 + 596 596 (% style="color:blue" %)**Downlink Command: 0x20** 597 597 598 598 Format: Command Code (0x20) followed by 1 bytes mode value. ... ... @@ -599,7 +599,7 @@ 599 599 600 600 If the downlink payload=2000, it means set the Network Join Mode, while type code is 20. 601 601 602 -* **Example 1: **Downlink Payload: **2000 597 +* **Example 1: **Downlink Payload: **2000 ** ~/~/ Set AT+NJM=0 603 603 * **Example 2:** Downlink Payload: **2001** ~/~/ Set AT+NJM=1 604 604 605 605 ... ... @@ -622,7 +622,6 @@ 622 622 623 623 624 624 625 - 626 626 == 6.6 Print Last Received Data in Raw Format == 627 627 628 628 ... ... @@ -640,7 +640,6 @@ 640 640 641 641 642 642 643 - 644 644 == 6.7 Print Last Received Data in Binary Format == 645 645 646 646 ... ... @@ -658,7 +658,6 @@ 658 658 659 659 660 660 661 - 662 662 == 6.8 Send Text Data == 663 663 664 664 ... ... @@ -680,7 +680,6 @@ 680 680 681 681 682 682 683 - 684 684 == 6.9 Send Hexadecimal Data == 685 685 686 686 ... ... @@ -689,11 +689,11 @@ 689 689 690 690 (% style="color:blue" %)**AT Command: AT+SENDB** 691 691 692 -(% border="1" style="background-color:#ffffcc; color:green; width:110 1px" %)693 -|=(% colspan="3" style="width: 1 098px;" %)AT+SENDB694 -|(% style="width:257px" %)**Command Example**|(% style="width: 394px" %)**Function**|(% style="width:446px" %)**Response**695 -|(% style="width:257px" %)AT+SENDB=12:abcdef0123456789|(% style="width: 394px" %)Send hexadecimal data along with the application port.|(% style="width:446px" %)OK696 -|(% style="width:257px" %)AT+SENDB=abcdef0123456789|(% style="width: 394px" %)Send hexadecimal data along with the application port.|(% style="width:446px" %)While Error in format, return(((683 +(% border="1" style="background-color:#ffffcc; color:green; width:1120.22px" %) 684 +|=(% colspan="3" style="width: 1117px;" %)AT+SENDB 685 +|(% style="width:257px" %)**Command Example**|(% style="width:406px" %)**Function**|(% style="width:453px" %)**Response** 686 +|(% style="width:257px" %)AT+SENDB=12:abcdef0123456789|(% style="width:406px" %)Send hexadecimal data along with the application port.|(% style="width:453px" %)OK 687 +|(% style="width:257px" %)AT+SENDB=abcdef0123456789|(% style="width:406px" %)Send hexadecimal data along with the application port.|(% style="width:453px" %)While Error in format, return((( 697 697 AT_PARAM_ERROR AT_BUSY_ERROR/AT_NO_NETWORK_JOINED 698 698 699 699 ... ... @@ -701,9 +701,9 @@ 701 701 702 702 703 703 704 - 705 705 = 7. LoRaWAN network management = 706 706 697 + 707 707 == 7.1 Adaptive Data Rate == 708 708 709 709 ... ... @@ -723,6 +723,7 @@ 723 723 AT_PARAM_ERROR 724 724 ))) 725 725 717 + 726 726 (% style="color:blue" %)**Downlink Command: 0x22** 727 727 728 728 If the downlink payload=2201, it means setting the adaptive data rate to 1, while type code is 22. ... ... @@ -739,7 +739,7 @@ 739 739 Feature: Get or Set the Device Class(Currently only support class A, class C). 740 740 741 741 742 -(% style="color:blue" %)**AT Command: 734 +(% style="color:blue" %)**AT Command:AT+CLASS** 743 743 744 744 (% border="1" style="background-color:#ffffcc; color:green; width:507.222px" %) 745 745 |=(% colspan="3" style="width: 504px;" %)AT+CLASS ... ... @@ -753,14 +753,13 @@ 753 753 754 754 755 755 756 - 757 757 == 7.3 Duty Cycle Setting == 758 758 759 759 760 -Feature: Get or Set the ETSI Duty Cycle setting **- 0**=disable,**1**=enable - Only for testing.751 +Feature: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing. 761 761 762 762 763 -(% style="color:blue" %)**AT Command: 754 +(% style="color:blue" %)**AT Command:AT+DCS** 764 764 765 765 (% border="1" style="background-color:#ffffcc; color:green; width:515.222px" %) 766 766 |=(% colspan="3" style="width: 512px;" %)AT+DCS ... ... @@ -774,7 +774,6 @@ 774 774 775 775 776 776 777 - 778 778 == 7.4 Data Rate == 779 779 780 780 ... ... @@ -793,6 +793,7 @@ 793 793 794 794 ))) 795 795 786 + 796 796 (% style="color:blue" %)**Downlink Command: 0x2200aaFF** 797 797 798 798 If the downlink payload=220001FF, it means setting the data rate to 1, while type code is 22 00 aa FF. ... ... @@ -809,7 +809,7 @@ 809 809 Feature: Get or Set the Frame Counter Downlink. 810 810 811 811 812 -(% style="color:blue" %)**AT Command: 803 +(% style="color:blue" %)**AT Command:AT+FCD** 813 813 814 814 (% border="1" style="background-color:#ffffcc; color:green; width:693.222px" %) 815 815 |=(% colspan="3" style="width: 690px;" %)AT+FCD ... ... @@ -823,13 +823,12 @@ 823 823 824 824 825 825 826 - 827 827 == 7.6 Frame Counter Uplink == 828 828 829 829 Feature: Get or Set the Frame Counter Uplink. 830 830 831 831 832 -(% style="color:blue" %)**AT Command: 822 +(% style="color:blue" %)**AT Command:AT+FCU** 833 833 834 834 (% border="1" style="background-color:#ffffcc; color:green; width:534.222px" %) 835 835 |=(% colspan="3" style="width: 531px;" %)AT+FCU ... ... @@ -843,7 +843,6 @@ 843 843 844 844 845 845 846 - 847 847 == 7.7 Join Accept Delay1 == 848 848 849 849 ... ... @@ -850,7 +850,7 @@ 850 850 Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms. 851 851 852 852 853 -(% style="color:blue" %)**AT Command: 842 +(% style="color:blue" %)**AT Command:AT+JN1DL** 854 854 855 855 (% border="1" style="background-color:#ffffcc; color:green; width:537.222px" %) 856 856 |=(% colspan="3" style="width: 534px;" %)AT+JN1DL ... ... @@ -864,14 +864,12 @@ 864 864 865 865 866 866 867 - 868 868 == 7.8 Join Accept Delay2 == 869 869 870 - 871 871 Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms. 872 872 873 873 874 -(% style="color:blue" %)**AT Command: 861 +(% style="color:blue" %)**AT Command:AT+JN2DL** 875 875 876 876 (% border="1" style="background-color:#ffffcc; color:green; width:538.222px" %) 877 877 |=(% colspan="3" style="width: 535px;" %)AT+JN2DL ... ... @@ -885,16 +885,15 @@ 885 885 886 886 887 887 888 - 889 889 == 7.9 Public Network Mode == 890 890 891 891 892 892 Feature: Get or Set the public network mode. (0: off, 1: on). A Public LoRaWAN network use 0x34 as syncword. Default Settings; PNM=1 893 893 894 -(% style="color:red" %) **Notice: If user build their own LoRaWAN server but still use syncword=0x34, this is still considered a public LoRaWAN network.**880 +(% style="color:red" %)Notice: If user build their own LoRaWAN server but still use syncword=0x34, this is still considered a public LoRaWAN network 895 895 896 896 897 -(% style="color:blue" %)**AT Command: 883 +(% style="color:blue" %)**AT Command:AT+PNM** 898 898 899 899 (% border="1" style="background-color:#ffffcc; color:green; width:667.222px" %) 900 900 |=(% colspan="3" style="width: 664px;" %)AT+PNM ... ... @@ -915,7 +915,6 @@ 915 915 916 916 917 917 918 - 919 919 == 7.10 Receive Delay1 == 920 920 921 921 ... ... @@ -922,7 +922,7 @@ 922 922 Feature: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 923 923 924 924 925 -(% style="color:blue" %)**AT Command: 910 +(% style="color:blue" %)**AT Command:AT+RX1DL** 926 926 927 927 (% border="1" style="background-color:#ffffcc; color:green; width:408.222px" %) 928 928 |=(% colspan="3" style="width: 405px;" %)AT+RX1DL ... ... @@ -936,7 +936,6 @@ 936 936 937 937 938 938 939 - 940 940 == 7.11 Receive Delay2 == 941 941 942 942 ... ... @@ -943,7 +943,7 @@ 943 943 Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 944 944 945 945 946 -(% style="color:blue" %)**AT Command: 930 +(% style="color:blue" %)**AT Command:AT+RX2DL** 947 947 948 948 (% border="1" style="background-color:#ffffcc; color:green; width:481.222px" %) 949 949 |=(% colspan="3" style="width: 478px;" %)AT+RX2DL ... ... @@ -957,7 +957,6 @@ 957 957 958 958 959 959 960 - 961 961 == 7.12 Rx2 Window Data Rate == 962 962 963 963 ... ... @@ -964,7 +964,7 @@ 964 964 Feature: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 965 965 966 966 967 -(% style="color:blue" %)**AT Command: 950 +(% style="color:blue" %)**AT Command:AT+RX2DR** 968 968 969 969 (% border="1" style="background-color:#ffffcc; color:green; width:525.222px" %) 970 970 |=(% colspan="3" style="width: 522px;" %)AT+RX2DR ... ... @@ -978,7 +978,6 @@ 978 978 979 979 980 980 981 - 982 982 == 7.13 Rx2 Window Frequency == 983 983 984 984 ... ... @@ -985,7 +985,7 @@ 985 985 Feature: Get or Set the Rx2 window frequency 986 986 987 987 988 -(% style="color:blue" %)**AT Command: 970 +(% style="color:blue" %)**AT Command:AT+RX2FQ** 989 989 990 990 (% border="1" style="background-color:#ffffcc; color:green; width:587.222px" %) 991 991 |=(% colspan="3" style="width: 584px;" %)AT+RX2FQ ... ... @@ -999,17 +999,14 @@ 999 999 1000 1000 1001 1001 1002 - 1003 1003 == 7.14 Transmit Power == 1004 1004 1005 1005 1006 1006 Feature: Get or Set the Transmit Power(0-5, MAX:0, MIN:5, according to LoRaWAN Spec, or 40=10dB, 41 = 11dB, …, 50 = 20dB which is out of LoRaWAN spec. ) 1007 1007 1008 -(% style="color:red" %)**Notice: Transmit Power might be changed by ADR from LoRaWAN server. So manually change TXP also remember to set AT+ADR=0 in sensor** 1009 1009 990 +(% style="color:blue" %)**AT Command:AT+TXP** 1010 1010 1011 -(% style="color:blue" %)**AT Command: AT+TXP** 1012 - 1013 1013 (% border="1" style="background-color:#ffffcc; color:green; width:465.222px" %) 1014 1014 |=(% colspan="3" style="width: 462px;" %)AT+TXP 1015 1015 |(% style="width:161px" %)**Command Example**|(% style="width:189px" %)**Function**|(% style="width:112px" %)**Response** ... ... @@ -1020,6 +1020,7 @@ 1020 1020 1021 1021 ))) 1022 1022 1002 + 1023 1023 Downlink Payload. The 4th byte of 0x22 downlink. 1024 1024 1025 1025 If the downlink payload=22000100, it means setting the TXP to 0. ... ... @@ -1047,7 +1047,6 @@ 1047 1047 1048 1048 1049 1049 1050 - 1051 1051 == 7.16 SNR of the Last Received Packet == 1052 1052 1053 1053 ... ... @@ -1054,7 +1054,7 @@ 1054 1054 Feature: Get the SNR of the last received packet 1055 1055 1056 1056 1057 -(% style="color:blue" %)**AT Command: 1036 +(% style="color:blue" %)**AT Command:AT+SNR** 1058 1058 1059 1059 (% border="1" style="background-color:#ffffcc; color:green; width:571.222px" %) 1060 1060 |=(% colspan="3" style="width: 568px;" %)AT+SNR ... ... @@ -1065,7 +1065,6 @@ 1065 1065 1066 1066 1067 1067 1068 - 1069 1069 == 7.17 Application Port == 1070 1070 1071 1071 ... ... @@ -1082,6 +1082,7 @@ 1082 1082 ))) 1083 1083 |(% style="width:157px" %)AT+PORT=21|(% style="width:204px" %)Set the application port|(% style="width:135px" %)OK 1084 1084 1063 + 1085 1085 (% style="color:blue" %)**Downlink Command: 0x23** 1086 1086 1087 1087 Format: Command Code (0x23) followed by 1 bytes port value. ... ... @@ -1093,7 +1093,6 @@ 1093 1093 1094 1094 1095 1095 1096 - 1097 1097 == 7.18 Single Channel Mode == 1098 1098 1099 1099 ... ... @@ -1112,10 +1112,8 @@ 1112 1112 1113 1113 1114 1114 1115 - 1116 1116 == 7.19 Eight Channel Mode == 1117 1117 1118 - 1119 1119 Feature: Get or Set eight channels mode,Only for US915,AU915,CN470. 1120 1120 1121 1121 ... ... @@ -1131,6 +1131,7 @@ 1131 1131 ))) 1132 1132 |(% style="width:160px" %)AT+CHE=1|(% style="width:198px" %)Set eight channels mode|(% style="width:349px" %)OK 1133 1133 1110 + 1134 1134 (% style="color:blue" %)**Downlink Command: 0x24** 1135 1135 1136 1136 Format: Command Code (0x24) followed by 1 bytes channel value. ... ... @@ -1162,9 +1162,8 @@ 1162 1162 ((( 1163 1163 1164 1164 1142 +**AT+RX1TWO** is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 1165 1165 1166 -(% style="color:blue" %)**AT+RX1WTO**(%%) is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 1167 - 1168 1168 1169 1169 ))) 1170 1170 ... ... @@ -1174,7 +1174,6 @@ 1174 1174 ((( 1175 1175 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 1176 1176 1177 - 1178 1178 1179 1179 ))) 1180 1180 ... ... @@ -1196,7 +1196,6 @@ 1196 1196 1197 1197 1198 1198 1199 - 1200 1200 == 7.22 Setting up uplinkdwelltime (as923, au915) == 1201 1201 1202 1202 ... ... @@ -1213,6 +1213,7 @@ 1213 1213 ))) 1214 1214 |(% style="width:183px" %)AT+DWELLT=0|(% style="width:179px" %)Set uplinkdwelltime|(% style="width:131px" %)OK 1215 1215 1190 + 1216 1216 (% style="color:blue" %)**Downlink Command: 0x25** 1217 1217 1218 1218 Format: Command Code (0x25) followed by 1 bytes state value. ... ... @@ -1239,6 +1239,7 @@ 1239 1239 * **AT+RPL=3:** Device will immediately reply message to MAC Command. Payload is 0x00 and requied response header for this command. 1240 1240 * **AT+RPL=4: **Device will immediately reply message to Confirmed Data Down & MAC Command. Payload is 0x00 and requied response header for these two commands. 1241 1241 1217 + 1242 1242 **Case Analyes:** 1243 1243 1244 1244 * For Class A devices, AT+RPL=0 is ok. that is defaut settings in software. ... ... @@ -1245,6 +1245,7 @@ 1245 1245 * For Class C devices used in ChirpStack, need to set AT+RPL=4 because Chirpstack require immedietely reply message to MAC Command. 1246 1246 * For Class C devices used in TTI, need to set AT+RPL=4 because TTI require immediately reply message to Confirmed Data Down & MAC Command. 1247 1247 1224 + 1248 1248 (% style="color:blue" %)**AT Command: AT+RPL** 1249 1249 1250 1250 (% border="1" style="background-color:#ffffcc; color:green; width:536.222px" %) ... ... @@ -1255,6 +1255,7 @@ 1255 1255 ))) 1256 1256 |(% style="width:160px" %)AT+RPL=0|(% style="width:263px" %)Set packet receiving response level|(% style="width:109px" %)OK 1257 1257 1235 + 1258 1258 (% style="color:blue" %)**Downlink Command: 0x21** 1259 1259 1260 1260 Format: Command Code (0x21) followed by 1 bytes level value. ... ... @@ -1288,6 +1288,7 @@ 1288 1288 OK 1289 1289 ))) 1290 1290 1269 + 1291 1291 (% style="color:blue" %)**Downlink Command: 0x33** 1292 1292 1293 1293 Format: Command Code (0x33) followed by 2 bytes mode value. ... ... @@ -1299,7 +1299,6 @@ 1299 1299 1300 1300 1301 1301 1302 - 1303 1303 == 7.25 Device offline rejoining (LWS007) == 1304 1304 1305 1305 ... ... @@ -1336,6 +1336,7 @@ 1336 1336 OK 1337 1337 ))) 1338 1338 1317 + 1339 1339 (% style="color:blue" %)**Downlink Command: 0x33** 1340 1340 1341 1341 Format: Command Code (0x32) followed by 2 bytes mode value. ... ... @@ -1346,7 +1346,6 @@ 1346 1346 1347 1347 1348 1348 1349 - 1350 1350 == 7.26 Request the server to send an ACK == 1351 1351 1352 1352 ... ... @@ -1366,7 +1366,6 @@ 1366 1366 1367 1367 1368 1368 1369 - 1370 1370 == 7.27 Adjust network rejoining interval == 1371 1371 1372 1372 ... ... @@ -1384,6 +1384,7 @@ 1384 1384 Set the ReJoin data transmission interval to 60000ms = 60 seconds 1385 1385 ))) 1386 1386 1364 + 1387 1387 (% style="color:blue" %)**Downlink Command: 0x26** 1388 1388 1389 1389 Format: Command Code (0x26) followed by 2 bytes mode value. ... ... @@ -1395,18 +1395,17 @@ 1395 1395 1396 1396 1397 1397 1398 - 1399 1399 = 8. AT Commands Combination = 1400 1400 1378 + 1401 1401 == 8.1 Set a fix RX2DR for downlink window == 1402 1402 1403 1403 1404 -* (% style="color:blue" %)**AT+ADR=0 **(%%)**~-~->** Disable ADR first1405 -* (% style="color:blue" %)**AT+RX2DR=xxxx**(%%)**~-~->** Set xxxx to your wanted DataRate1382 +* **AT+ADR=0 ** **~-~->** Disable ADR first 1383 +* **AT+RX2DR=xxxx** **~-~->** Set xxxx to your wanted DataRate 1406 1406 1407 1407 1408 1408 1409 - 1410 1410 == 8.2 Use Downlink Command to set a fix uplink DR == 1411 1411 1412 1412 ... ... @@ -1417,5 +1417,3 @@ 1417 1417 * AT+ADR=0 [[Reference>>||anchor="H7.1AdaptiveDataRate"]] 1418 1418 * AT+DR=5 [[Reference>>||anchor="H7.4DataRate"]] 1419 1419 * AT+TXP=0 [[Reference>>||anchor="H7.14TransmitPower"]] 1420 - 1421 -