Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,8 +9,8 @@ 9 9 10 10 Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands: 11 11 12 -* (% style="color:blue" %)**Common Commands:**(%%)They should be available for each sensor, such as: change uplink interval, reset device.13 -* (% style="color:blue" %)**Sensor Related Commands:**(%%)Only for special sensor, such as control relay, poll RS485 device.12 +* **Common Commands:** They should be available for each sensor, such as: change uplink interval, reset device. 13 +* **Sensor Related Commands:** Only for special sensor, such as control relay, poll RS485 device. 14 14 15 15 ((( 16 16 **This page shows the common commands since Dragino LoRaWAN stack DR-LWS-005. Make sure the end node support stack higher than DR-LWS-005 before checking this page.** ... ... @@ -107,7 +107,6 @@ 107 107 108 108 109 109 110 - 111 111 = 4. System Management Commands = 112 112 113 113 ... ... @@ -140,7 +140,7 @@ 140 140 ))) 141 141 142 142 ((( 143 -If the downlink payload=0100003C, it means set the END Node 's Transmit Interval to 0x00003C=60(S), while type code is 01.142 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 144 144 ))) 145 145 146 146 * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds ... ... @@ -148,7 +148,6 @@ 148 148 149 149 150 150 151 - 152 152 == 4.2 Reboot End Node == 153 153 154 154 ... ... @@ -316,7 +316,6 @@ 316 316 317 317 318 318 319 - 320 320 = 5. Keys, IDs and EUIs management = 321 321 322 322 ... ... @@ -338,7 +338,6 @@ 338 338 339 339 340 340 341 - 342 342 == 5.2 Application Key == 343 343 344 344 ... ... @@ -357,7 +357,6 @@ 357 357 358 358 359 359 360 - 361 361 == 5.3 Application Session Key == 362 362 363 363 ... ... @@ -378,7 +378,6 @@ 378 378 379 379 380 380 381 - 382 382 == 5.4 Device Address == 383 383 384 384 ... ... @@ -399,7 +399,6 @@ 399 399 400 400 401 401 402 - 403 403 == 5.5 Device EUI == 404 404 405 405 ... ... @@ -420,7 +420,6 @@ 420 420 421 421 422 422 423 - 424 424 == 5.6 Network ID == 425 425 426 426 ... ... @@ -439,7 +439,6 @@ 439 439 440 440 441 441 442 - 443 443 == 5.7 Network Session Key == 444 444 445 445 ... ... @@ -458,7 +458,6 @@ 458 458 459 459 460 460 461 - 462 462 = 6. Joining and sending date on LoRaWAN network = 463 463 464 464 ... ... @@ -482,8 +482,6 @@ 482 482 |(% style="width:155px" %)AT+CFM=1|(% style="width:205px" %)Set the confirmation mode|(% style="width:346px" %)OK 483 483 |(% style="width:155px" %)AT+CFM=2|(% style="width:205px" %)Set the confirmation mode|(% style="width:346px" %)While Error in format, return AT_PARAM_ERROR 484 484 485 - 486 - 487 487 (% style="color:blue" %)**Downlink Command: 0x05** 488 488 489 489 Format: Command Code (0x05) followed by 2 bytes mode value. ... ... @@ -495,7 +495,6 @@ 495 495 496 496 497 497 498 - 499 499 === 6.1.2 AT+CFM command since DR-LWS007 software stack === 500 500 501 501 ... ... @@ -532,8 +532,6 @@ 532 532 OK 533 533 ))) 534 534 535 - 536 - 537 537 (% style="color:blue" %)**Downlink Command: 0x05** 538 538 539 539 Format: Command Code (0x05) followed by 2 bytes mode value. ... ... @@ -545,7 +545,6 @@ 545 545 546 546 547 547 548 - 549 549 == 6.2 Confirm Status == 550 550 551 551 ... ... @@ -563,7 +563,6 @@ 563 563 564 564 565 565 566 - 567 567 == 6.3 Join LoRa® Network == 568 568 569 569 ... ... @@ -583,7 +583,6 @@ 583 583 584 584 585 585 586 - 587 587 == 6.4 LoRa® Network Join Mode == 588 588 589 589 ... ... @@ -601,8 +601,6 @@ 601 601 |(% style="width:162px" %)AT+NJM=0|(% style="width:227px" %)Set the Network Join Mode|(% style="width:361px" %)OK 602 602 |(% style="width:162px" %)AT+NJM=2|(% style="width:227px" %)Set the Network Join Mode|(% style="width:361px" %)While Error in format, return AT_PARAM_ERROR 603 603 604 - 605 - 606 606 (% style="color:blue" %)**Downlink Command: 0x20** 607 607 608 608 Format: Command Code (0x20) followed by 1 bytes mode value. ... ... @@ -614,7 +614,6 @@ 614 614 615 615 616 616 617 - 618 618 == 6.5 LoRa® Network Join Status == 619 619 620 620 ... ... @@ -632,7 +632,6 @@ 632 632 633 633 634 634 635 - 636 636 == 6.6 Print Last Received Data in Raw Format == 637 637 638 638 ... ... @@ -650,7 +650,6 @@ 650 650 651 651 652 652 653 - 654 654 == 6.7 Print Last Received Data in Binary Format == 655 655 656 656 ... ... @@ -668,7 +668,6 @@ 668 668 669 669 670 670 671 - 672 672 == 6.8 Send Text Data == 673 673 674 674 ... ... @@ -690,7 +690,6 @@ 690 690 691 691 692 692 693 - 694 694 == 6.9 Send Hexadecimal Data == 695 695 696 696 ... ... @@ -699,11 +699,11 @@ 699 699 700 700 (% style="color:blue" %)**AT Command: AT+SENDB** 701 701 702 -(% border="1" style="background-color:#ffffcc; color:green; width:110 1px" %)703 -|=(% colspan="3" style="width: 1 098px;" %)AT+SENDB704 -|(% style="width:257px" %)**Command Example**|(% style="width: 394px" %)**Function**|(% style="width:446px" %)**Response**705 -|(% style="width:257px" %)AT+SENDB=12:abcdef0123456789|(% style="width: 394px" %)Send hexadecimal data along with the application port.|(% style="width:446px" %)OK706 -|(% style="width:257px" %)AT+SENDB=abcdef0123456789|(% style="width: 394px" %)Send hexadecimal data along with the application port.|(% style="width:446px" %)While Error in format, return(((677 +(% border="1" style="background-color:#ffffcc; color:green; width:1120.22px" %) 678 +|=(% colspan="3" style="width: 1117px;" %)AT+SENDB 679 +|(% style="width:257px" %)**Command Example**|(% style="width:406px" %)**Function**|(% style="width:453px" %)**Response** 680 +|(% style="width:257px" %)AT+SENDB=12:abcdef0123456789|(% style="width:406px" %)Send hexadecimal data along with the application port.|(% style="width:453px" %)OK 681 +|(% style="width:257px" %)AT+SENDB=abcdef0123456789|(% style="width:406px" %)Send hexadecimal data along with the application port.|(% style="width:453px" %)While Error in format, return((( 707 707 AT_PARAM_ERROR AT_BUSY_ERROR/AT_NO_NETWORK_JOINED 708 708 709 709 ... ... @@ -711,7 +711,6 @@ 711 711 712 712 713 713 714 - 715 715 = 7. LoRaWAN network management = 716 716 717 717 ... ... @@ -734,8 +734,6 @@ 734 734 AT_PARAM_ERROR 735 735 ))) 736 736 737 - 738 - 739 739 (% style="color:blue" %)**Downlink Command: 0x22** 740 740 741 741 If the downlink payload=2201, it means setting the adaptive data rate to 1, while type code is 22. ... ... @@ -745,7 +745,6 @@ 745 745 746 746 747 747 748 - 749 749 == 7.2 LoRa® Class == 750 750 751 751 ... ... @@ -752,7 +752,7 @@ 752 752 Feature: Get or Set the Device Class(Currently only support class A, class C). 753 753 754 754 755 -(% style="color:blue" %)**AT Command: 726 +(% style="color:blue" %)**AT Command:AT+CLASS** 756 756 757 757 (% border="1" style="background-color:#ffffcc; color:green; width:507.222px" %) 758 758 |=(% colspan="3" style="width: 504px;" %)AT+CLASS ... ... @@ -766,14 +766,13 @@ 766 766 767 767 768 768 769 - 770 770 == 7.3 Duty Cycle Setting == 771 771 772 772 773 -Feature: Get or Set the ETSI Duty Cycle setting **- 0**=disable,**1**=enable - Only for testing.743 +Feature: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing. 774 774 775 775 776 -(% style="color:blue" %)**AT Command: 746 +(% style="color:blue" %)**AT Command:AT+DCS** 777 777 778 778 (% border="1" style="background-color:#ffffcc; color:green; width:515.222px" %) 779 779 |=(% colspan="3" style="width: 512px;" %)AT+DCS ... ... @@ -787,7 +787,6 @@ 787 787 788 788 789 789 790 - 791 791 == 7.4 Data Rate == 792 792 793 793 ... ... @@ -806,8 +806,6 @@ 806 806 807 807 ))) 808 808 809 - 810 - 811 811 (% style="color:blue" %)**Downlink Command: 0x2200aaFF** 812 812 813 813 If the downlink payload=220001FF, it means setting the data rate to 1, while type code is 22 00 aa FF. ... ... @@ -817,7 +817,6 @@ 817 817 818 818 819 819 820 - 821 821 == 7.5 Frame Counter Downlink == 822 822 823 823 ... ... @@ -824,7 +824,7 @@ 824 824 Feature: Get or Set the Frame Counter Downlink. 825 825 826 826 827 -(% style="color:blue" %)**AT Command: 793 +(% style="color:blue" %)**AT Command:AT+FCD** 828 828 829 829 (% border="1" style="background-color:#ffffcc; color:green; width:693.222px" %) 830 830 |=(% colspan="3" style="width: 690px;" %)AT+FCD ... ... @@ -838,13 +838,12 @@ 838 838 839 839 840 840 841 - 842 842 == 7.6 Frame Counter Uplink == 843 843 844 844 Feature: Get or Set the Frame Counter Uplink. 845 845 846 846 847 -(% style="color:blue" %)**AT Command: 812 +(% style="color:blue" %)**AT Command:AT+FCU** 848 848 849 849 (% border="1" style="background-color:#ffffcc; color:green; width:534.222px" %) 850 850 |=(% colspan="3" style="width: 531px;" %)AT+FCU ... ... @@ -858,7 +858,6 @@ 858 858 859 859 860 860 861 - 862 862 == 7.7 Join Accept Delay1 == 863 863 864 864 ... ... @@ -865,7 +865,7 @@ 865 865 Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms. 866 866 867 867 868 -(% style="color:blue" %)**AT Command: 832 +(% style="color:blue" %)**AT Command:AT+JN1DL** 869 869 870 870 (% border="1" style="background-color:#ffffcc; color:green; width:537.222px" %) 871 871 |=(% colspan="3" style="width: 534px;" %)AT+JN1DL ... ... @@ -879,14 +879,12 @@ 879 879 880 880 881 881 882 - 883 883 == 7.8 Join Accept Delay2 == 884 884 885 - 886 886 Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms. 887 887 888 888 889 -(% style="color:blue" %)**AT Command: 851 +(% style="color:blue" %)**AT Command:AT+JN2DL** 890 890 891 891 (% border="1" style="background-color:#ffffcc; color:green; width:538.222px" %) 892 892 |=(% colspan="3" style="width: 535px;" %)AT+JN2DL ... ... @@ -900,7 +900,6 @@ 900 900 901 901 902 902 903 - 904 904 == 7.9 Public Network Mode == 905 905 906 906 ... ... @@ -909,7 +909,7 @@ 909 909 (% style="color:red" %)**Notice: If user build their own LoRaWAN server but still use syncword=0x34, this is still considered a public LoRaWAN network.** 910 910 911 911 912 -(% style="color:blue" %)**AT Command: 873 +(% style="color:blue" %)**AT Command:AT+PNM** 913 913 914 914 (% border="1" style="background-color:#ffffcc; color:green; width:667.222px" %) 915 915 |=(% colspan="3" style="width: 664px;" %)AT+PNM ... ... @@ -930,7 +930,6 @@ 930 930 931 931 932 932 933 - 934 934 == 7.10 Receive Delay1 == 935 935 936 936 ... ... @@ -937,7 +937,7 @@ 937 937 Feature: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms 938 938 939 939 940 -(% style="color:blue" %)**AT Command: 900 +(% style="color:blue" %)**AT Command:AT+RX1DL** 941 941 942 942 (% border="1" style="background-color:#ffffcc; color:green; width:408.222px" %) 943 943 |=(% colspan="3" style="width: 405px;" %)AT+RX1DL ... ... @@ -951,7 +951,6 @@ 951 951 952 952 953 953 954 - 955 955 == 7.11 Receive Delay2 == 956 956 957 957 ... ... @@ -958,7 +958,7 @@ 958 958 Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 959 959 960 960 961 -(% style="color:blue" %)**AT Command: 920 +(% style="color:blue" %)**AT Command:AT+RX2DL** 962 962 963 963 (% border="1" style="background-color:#ffffcc; color:green; width:481.222px" %) 964 964 |=(% colspan="3" style="width: 478px;" %)AT+RX2DL ... ... @@ -972,7 +972,6 @@ 972 972 973 973 974 974 975 - 976 976 == 7.12 Rx2 Window Data Rate == 977 977 978 978 ... ... @@ -979,7 +979,7 @@ 979 979 Feature: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 980 980 981 981 982 -(% style="color:blue" %)**AT Command: 940 +(% style="color:blue" %)**AT Command:AT+RX2DR** 983 983 984 984 (% border="1" style="background-color:#ffffcc; color:green; width:525.222px" %) 985 985 |=(% colspan="3" style="width: 522px;" %)AT+RX2DR ... ... @@ -993,7 +993,6 @@ 993 993 994 994 995 995 996 - 997 997 == 7.13 Rx2 Window Frequency == 998 998 999 999 ... ... @@ -1000,7 +1000,7 @@ 1000 1000 Feature: Get or Set the Rx2 window frequency 1001 1001 1002 1002 1003 -(% style="color:blue" %)**AT Command: 960 +(% style="color:blue" %)**AT Command:AT+RX2FQ** 1004 1004 1005 1005 (% border="1" style="background-color:#ffffcc; color:green; width:587.222px" %) 1006 1006 |=(% colspan="3" style="width: 584px;" %)AT+RX2FQ ... ... @@ -1014,16 +1014,15 @@ 1014 1014 1015 1015 1016 1016 1017 - 1018 1018 == 7.14 Transmit Power == 1019 1019 1020 1020 1021 1021 Feature: Get or Set the Transmit Power(0-5, MAX:0, MIN:5, according to LoRaWAN Spec, or 40=10dB, 41 = 11dB, …, 50 = 20dB which is out of LoRaWAN spec. ) 1022 1022 1023 - (% style="color:red" %)**Notice: Transmit Power might be changed by ADR from LoRaWAN server. So manually change TXP also remember to set AT+ADR=0 in sensor**979 +Notice: Transmit Power might be changed by ADR from LoRaWAN server. So manually change TXP also remember to set AT+ADR=0 in sensor 1024 1024 1025 1025 1026 -(% style="color:blue" %)**AT Command: 982 +(% style="color:blue" %)**AT Command:AT+TXP** 1027 1027 1028 1028 (% border="1" style="background-color:#ffffcc; color:green; width:465.222px" %) 1029 1029 |=(% colspan="3" style="width: 462px;" %)AT+TXP ... ... @@ -1044,7 +1044,6 @@ 1044 1044 1045 1045 1046 1046 1047 - 1048 1048 == 7.15 RSSI of the Last Received Packet == 1049 1049 1050 1050 ... ... @@ -1062,7 +1062,6 @@ 1062 1062 1063 1063 1064 1064 1065 - 1066 1066 == 7.16 SNR of the Last Received Packet == 1067 1067 1068 1068 ... ... @@ -1069,7 +1069,7 @@ 1069 1069 Feature: Get the SNR of the last received packet 1070 1070 1071 1071 1072 -(% style="color:blue" %)**AT Command: 1026 +(% style="color:blue" %)**AT Command:AT+SNR** 1073 1073 1074 1074 (% border="1" style="background-color:#ffffcc; color:green; width:571.222px" %) 1075 1075 |=(% colspan="3" style="width: 568px;" %)AT+SNR ... ... @@ -1080,7 +1080,6 @@ 1080 1080 1081 1081 1082 1082 1083 - 1084 1084 == 7.17 Application Port == 1085 1085 1086 1086 ... ... @@ -1097,8 +1097,6 @@ 1097 1097 ))) 1098 1098 |(% style="width:157px" %)AT+PORT=21|(% style="width:204px" %)Set the application port|(% style="width:135px" %)OK 1099 1099 1100 - 1101 - 1102 1102 (% style="color:blue" %)**Downlink Command: 0x23** 1103 1103 1104 1104 Format: Command Code (0x23) followed by 1 bytes port value. ... ... @@ -1129,7 +1129,6 @@ 1129 1129 1130 1130 1131 1131 1132 - 1133 1133 == 7.19 Eight Channel Mode == 1134 1134 1135 1135 ... ... @@ -1148,8 +1148,6 @@ 1148 1148 ))) 1149 1149 |(% style="width:160px" %)AT+CHE=1|(% style="width:198px" %)Set eight channels mode|(% style="width:349px" %)OK 1150 1150 1151 - 1152 - 1153 1153 (% style="color:blue" %)**Downlink Command: 0x24** 1154 1154 1155 1155 Format: Command Code (0x24) followed by 1 bytes channel value. ... ... @@ -1161,7 +1161,6 @@ 1161 1161 1162 1162 1163 1163 1164 - 1165 1165 == 7.20 Get or Set RXwindows1 timeout == 1166 1166 1167 1167 ... ... @@ -1181,9 +1181,8 @@ 1181 1181 ((( 1182 1182 1183 1183 1131 +**AT+RX1TWO** is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 1184 1184 1185 -(% style="color:blue" %)**AT+RX1WTO**(%%) is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 1186 - 1187 1187 1188 1188 ))) 1189 1189 ... ... @@ -1193,7 +1193,6 @@ 1193 1193 ((( 1194 1194 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 1195 1195 1196 - 1197 1197 1198 1198 ))) 1199 1199 ... ... @@ -1215,7 +1215,6 @@ 1215 1215 1216 1216 1217 1217 1218 - 1219 1219 == 7.22 Setting up uplinkdwelltime (as923, au915) == 1220 1220 1221 1221 ... ... @@ -1232,8 +1232,6 @@ 1232 1232 ))) 1233 1233 |(% style="width:183px" %)AT+DWELLT=0|(% style="width:179px" %)Set uplinkdwelltime|(% style="width:131px" %)OK 1234 1234 1235 - 1236 - 1237 1237 (% style="color:blue" %)**Downlink Command: 0x25** 1238 1238 1239 1239 Format: Command Code (0x25) followed by 1 bytes state value. ... ... @@ -1245,7 +1245,6 @@ 1245 1245 1246 1246 1247 1247 1248 - 1249 1249 == 7.23 Set Packet Receiving Response Level == 1250 1250 1251 1251 ... ... @@ -1266,9 +1266,6 @@ 1266 1266 * For Class C devices used in ChirpStack, need to set AT+RPL=4 because Chirpstack require immedietely reply message to MAC Command. 1267 1267 * For Class C devices used in TTI, need to set AT+RPL=4 because TTI require immediately reply message to Confirmed Data Down & MAC Command. 1268 1268 1269 - 1270 - 1271 - 1272 1272 (% style="color:blue" %)**AT Command: AT+RPL** 1273 1273 1274 1274 (% border="1" style="background-color:#ffffcc; color:green; width:536.222px" %) ... ... @@ -1279,8 +1279,6 @@ 1279 1279 ))) 1280 1280 |(% style="width:160px" %)AT+RPL=0|(% style="width:263px" %)Set packet receiving response level|(% style="width:109px" %)OK 1281 1281 1282 - 1283 - 1284 1284 (% style="color:blue" %)**Downlink Command: 0x21** 1285 1285 1286 1286 Format: Command Code (0x21) followed by 1 bytes level value. ... ... @@ -1292,7 +1292,6 @@ 1292 1292 1293 1293 1294 1294 1295 - 1296 1296 == 7.24 Controls NBTrans in unconfirmed uplink mode(LWS007 NBTrans:Set retransmission packets) == 1297 1297 1298 1298 ... ... @@ -1314,8 +1314,6 @@ 1314 1314 OK 1315 1315 ))) 1316 1316 1317 - 1318 - 1319 1319 (% style="color:blue" %)**Downlink Command: 0x33** 1320 1320 1321 1321 Format: Command Code (0x33) followed by 2 bytes mode value. ... ... @@ -1364,8 +1364,6 @@ 1364 1364 OK 1365 1365 ))) 1366 1366 1367 - 1368 - 1369 1369 (% style="color:blue" %)**Downlink Command: 0x33** 1370 1370 1371 1371 Format: Command Code (0x32) followed by 2 bytes mode value. ... ... @@ -1396,7 +1396,6 @@ 1396 1396 1397 1397 1398 1398 1399 - 1400 1400 == 7.27 Adjust network rejoining interval == 1401 1401 1402 1402 ... ... @@ -1414,8 +1414,6 @@ 1414 1414 Set the ReJoin data transmission interval to 60000ms = 60 seconds 1415 1415 ))) 1416 1416 1417 - 1418 - 1419 1419 (% style="color:blue" %)**Downlink Command: 0x26** 1420 1420 1421 1421 Format: Command Code (0x26) followed by 2 bytes mode value. ... ... @@ -1434,8 +1434,8 @@ 1434 1434 == 8.1 Set a fix RX2DR for downlink window == 1435 1435 1436 1436 1437 -* (% style="color:blue" %)**AT+ADR=0 **(%%)**~-~->** Disable ADR first1438 -* (% style="color:red" %)**AT+RX2DR=xxxx**(%%)**~-~->** Set xxxx to your wanted DataRate1365 +* **AT+ADR=0 ** **~-~->** Disable ADR first 1366 +* **AT+RX2DR=xxxx** **~-~->** Set xxxx to your wanted DataRate 1439 1439 1440 1440 1441 1441 ... ... @@ -1451,4 +1451,5 @@ 1451 1451 * AT+DR=5 [[Reference>>||anchor="H7.4DataRate"]] 1452 1452 * AT+TXP=0 [[Reference>>||anchor="H7.14TransmitPower"]] 1453 1453 1382 + 1454 1454