<
From version < 50.4 >
edited by Xiaoling
on 2022/07/13 11:50
To version < 50.1 >
edited by Edwin Chen
on 2022/06/22 14:26
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -1,4 +1,4 @@
1 - **Table of** **Contents:**
1 + **Contents:**
2 2  
3 3  {{toc/}}
4 4  
... ... @@ -6,7 +6,6 @@
6 6  
7 7  = 1. Introduction =
8 8  
9 -
10 10  Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
11 11  
12 12  * **Common Commands:** They should be available for each sensor, such as: change uplink interval, reset device.
... ... @@ -19,7 +19,6 @@
19 19  
20 20  = 2. How to use AT Commands or Downlink command =
21 21  
22 -
23 23  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
24 24  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
25 25  ** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
... ... @@ -26,11 +26,8 @@
26 26  ** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
27 27  ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
28 28  
29 -
30 -
31 31  = 3. Support End Node and firmware version =
32 32  
33 -
34 34  (% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
35 35  |=(% colspan="3" style="width: 963px;" %)(((
36 36  Dragino STM32 base hardware Firmware / LoRaWAN stack list
... ... @@ -102,14 +102,10 @@
102 102  )))
103 103  )))
104 104  
105 -
106 -
107 107  = 4. System Management Commands =
108 108  
109 -
110 110  == 4.1 Change Uplink Interval ==
111 111  
112 -
113 113  Feature: Change LoRaWAN End Node Transmit Interval.
114 114  
115 115  (% class="box infomessage" %)
... ... @@ -144,8 +144,6 @@
144 144  * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
145 145  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
146 146  
147 -
148 -
149 149  == 4.2 Reboot End Node ==
150 150  
151 151  Feature: Reboot End Node to perform a new OTAA or ABP Join.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0