<
From version < 42.1 >
edited by Bei Jinggeng
on 2022/06/10 11:15
To version < 39.2 >
edited by Bei Jinggeng
on 2022/06/10 10:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1086,52 +1086,23 @@
1086 1086  * **Example 1**: Downlink Payload: **2101** ~/~/ set packet receiving response level to 1
1087 1087  * **Example 2**: Downlink Payload: **2102** ~/~/ set packet receiving response level to 2
1088 1088  
1089 -== 7.24 Set retransmission packets(LWS007) ==
1089 +== 7.24 Set retransmission packets ==
1090 1090  
1091 -{{info}}
1092 -**AT Command: AT+CFM**
1093 -{{/info}}
1094 -
1095 1095  (% border="1" style="background-color:#ffffcc; color:green; width:710.222px" %)
1096 1096  |=(% colspan="3" style="width: 707px;" %)AT+CFM
1097 1097  |(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response**
1098 -|(% style="width:160px" %)(((
1099 -AT+CFM=1,0,0
1100 -
1101 -value1
1102 -)))|(% style="width:198px" %)confirmed uplink|(% style="width:349px" %)(((
1094 +|(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response**
1095 +|(% style="width:160px" %)value1|(% style="width:198px" %)confirmed uplink|(% style="width:349px" %)(((
1103 1103  1
1104 1104  
1105 1105  OK
1106 1106  )))
1107 -|(% style="width:160px" %)(((
1108 -AT+CFM=0,?,0
1100 +|(% style="width:160px" %)value2|(% style="width:198px" %)set max retry , range: 0 ~~ 7|(% style="width:349px" %)(((
1101 +
1109 1109  
1110 -value2
1111 -)))|(% style="width:198px" %)set max retry , range: 0 ~~ 7|(% style="width:349px" %)(((
1112 -0~~7
1113 -
1114 1114  OK
1115 1115  )))
1116 -|(% style="width:160px" %)(((
1117 -AT+CFM=0,0,1
1118 1118  
1119 -value3
1120 -)))|(% style="width:198px" %)uplink fcnt increase by 1 for each retry|(% style="width:349px" %)(((
1121 -1
1122 -
1123 -OK
1124 -)))
1125 -
1126 -Downlink Command: 0x05
1127 -
1128 -Format: Command Code (0x05) followed by 2 bytes mode value.
1129 -
1130 -If the downlink payload=0501, it means set end node to use confirm mode, while type code is 05.
1131 -
1132 -* Example 1: Downlink Payload: 05010101 ~/~/ Set AT+CFM=1,1,1
1133 -* Example 2: Downlink Payload: 05000700 ~/~/ Set AT+CFM=0,7,0
1134 -
1135 1135  = 8. AT Commands Combination =
1136 1136  
1137 1137  == 8.1 Set a fix RX2DR for downlink window ==
... ... @@ -1150,4 +1150,4 @@
1150 1150  * AT+ADR=0  [[Reference>>||anchor="H7.1AdaptiveDataRate"]]
1151 1151  * AT+DR=5  [[Reference>>||anchor="H7.4DataRate"]]
1152 1152  * AT+TXP=0  [[Reference>>||anchor="H7.14TransmitPower"]]
1153 -~)~)~)
1124 +)))
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0