Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -3,7 +3,6 @@ 3 3 {{toc/}} 4 4 5 5 6 - 7 7 = 1. Introduction = 8 8 9 9 Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands: ... ... @@ -20,9 +20,9 @@ 20 20 21 21 * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]] 22 22 * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command: 23 -** Use HEX format to send a downlink: [[TTN v3>>Notes 24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes 25 -** See use note for more serves [[Servers Note>>doc :Main.WebHome]](IoT LoRaWANServer)22 +** Use HEX format to send a downlink: [[TTN v3>>url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]] 23 +** Use Base64 format to send a downlink: [[Chirpstack>>url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]]. 24 +** See use note for more serves [[Servers Note>>url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]] 26 26 27 27 = 3. Support End Node and firmware version = 28 28 ... ... @@ -170,8 +170,6 @@ 170 170 171 171 ((( 172 172 If the downlink payload=**04FF**, the end node will reboot. 173 - 174 - 175 175 ))) 176 176 177 177 == 4.3 Reset to factory Default == ... ... @@ -793,7 +793,7 @@ 793 793 794 794 ))) 795 795 796 -== 7.11 793 +== 7.11Receive Delay2 == 797 797 798 798 Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 799 799 ... ... @@ -998,8 +998,6 @@ 998 998 999 999 ((( 1000 1000 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 1001 - 1002 - 1003 1003 ))) 1004 1004 1005 1005 == 7.21 Get or Set RXwindows2 timeout == ... ... @@ -1086,52 +1086,6 @@ 1086 1086 * **Example 1**: Downlink Payload: **2101** ~/~/ set packet receiving response level to 1 1087 1087 * **Example 2**: Downlink Payload: **2102** ~/~/ set packet receiving response level to 2 1088 1088 1089 -== 7.24 Set retransmission packets(LWS007) == 1090 - 1091 -{{info}} 1092 -**AT Command: AT+CFM** 1093 -{{/info}} 1094 - 1095 -(% border="1" style="background-color:#ffffcc; color:green; width:710.222px" %) 1096 -|=(% colspan="3" style="width: 707px;" %)AT+CFM 1097 -|(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response** 1098 -|(% style="width:160px" %)((( 1099 -AT+CFM=1,0,0 1100 - 1101 -value1 1102 -)))|(% style="width:198px" %)confirmed uplink|(% style="width:349px" %)((( 1103 -1 1104 - 1105 -OK 1106 -))) 1107 -|(% style="width:160px" %)((( 1108 -AT+CFM=0,?,0 1109 - 1110 -value2 1111 -)))|(% style="width:198px" %)set max retry , range: 0 ~~ 7|(% style="width:349px" %)((( 1112 -0~~7 1113 - 1114 -OK 1115 -))) 1116 -|(% style="width:160px" %)((( 1117 -AT+CFM=0,0,1 1118 - 1119 -value3 1120 -)))|(% style="width:198px" %)uplink fcnt increase by 1 for each retry|(% style="width:349px" %)((( 1121 -1 1122 - 1123 -OK 1124 -))) 1125 - 1126 -Downlink Command: 0x05 1127 - 1128 -Format: Command Code (0x05) followed by 2 bytes mode value. 1129 - 1130 -If the downlink payload=0501, it means set end node to use confirm mode, while type code is 05. 1131 - 1132 -* Example 1: Downlink Payload: 05010101 ~/~/ Set AT+CFM=1,1,1 1133 -* Example 2: Downlink Payload: 05000700 ~/~/ Set AT+CFM=0,7,0 1134 - 1135 1135 = 8. AT Commands Combination = 1136 1136 1137 1137 == 8.1 Set a fix RX2DR for downlink window == ... ... @@ -1147,7 +1147,6 @@ 1147 1147 1148 1148 Same as: 1149 1149 1150 -* AT+ADR=0 [[Reference>>||anchor="H7.1AdaptiveDataRate"]] 1151 -* AT+DR=5 [[Reference>>||anchor="H7.4DataRate"]] 1152 -* AT+TXP=0 [[Reference>>||anchor="H7.14TransmitPower"]] 1153 -~)~)~) 1099 +* AT+ADR=0 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.1AdaptiveDataRate]] 1100 +* AT+DR=5 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]] 1101 +* AT+TXP=0 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.14TransmitPower]]