<
From version < 38.9 >
edited by Xiaoling
on 2022/05/30 10:51
To version < 38.19 >
edited by Xiaoling
on 2022/05/31 09:05
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,9 +20,9 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]].
25 -** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
23 +** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 +** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
25 +** See use note for more serves [[Servers Note>>WebHome]](IoT LoRaWAN Server)
26 26  
27 27  = 3. Support End Node and firmware version =
28 28  
... ... @@ -97,7 +97,6 @@
97 97  )))
98 98  )))
99 99  
100 -
101 101  = 4. System Management Commands =
102 102  
103 103  == 4.1 Change Uplink Interval ==
... ... @@ -136,7 +136,6 @@
136 136  * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
137 137  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
138 138  
139 -
140 140  == 4.2 Reboot End Node ==
141 141  
142 142  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -298,8 +298,6 @@
298 298  OK
299 299  )))
300 300  
301 -
302 -
303 303  = 5. Keys, IDs and EUIs management =
304 304  
305 305  == 5.1 Application EUI ==
... ... @@ -318,7 +318,6 @@
318 318  )))
319 319  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
320 320  
321 -
322 322  == 5.2 Application Key ==
323 323  
324 324  Feature: Get or Set the Application Key.
... ... @@ -335,7 +335,6 @@
335 335  )))
336 336  |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK
337 337  
338 -
339 339  == 5.3 Application Session Key ==
340 340  
341 341  Feature: Get or Set the Application Session Key.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0