<
From version < 38.9 >
edited by Xiaoling
on 2022/05/30 10:51
To version < 19.5 >
edited by Xiaoling
on 2022/05/26 16:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,7 +3,6 @@
3 3  {{toc/}}
4 4  
5 5  
6 -
7 7  = 1. Introduction =
8 8  
9 9  Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
... ... @@ -20,9 +20,9 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]].
25 -** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
22 +** Use HEX format to send a downlink: [[TTN v3>>url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]]
23 +** Use Base64 format to send a downlink: [[Chirpstack>>url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]].
24 +** See use note for more serves [[Servers Note>>url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]]
26 26  
27 27  = 3. Support End Node and firmware version =
28 28  
... ... @@ -97,7 +97,6 @@
97 97  )))
98 98  )))
99 99  
100 -
101 101  = 4. System Management Commands =
102 102  
103 103  == 4.1 Change Uplink Interval ==
... ... @@ -136,7 +136,6 @@
136 136  * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
137 137  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
138 138  
139 -
140 140  == 4.2 Reboot End Node ==
141 141  
142 142  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -172,8 +172,6 @@
172 172  
173 173  (((
174 174  If the downlink payload=**04FF**, the end node will reboot.
175 -
176 -
177 177  )))
178 178  
179 179  == 4.3 Reset to factory Default ==
... ... @@ -298,8 +298,6 @@
298 298  OK
299 299  )))
300 300  
301 -
302 -
303 303  = 5. Keys, IDs and EUIs management =
304 304  
305 305  == 5.1 Application EUI ==
... ... @@ -318,7 +318,6 @@
318 318  )))
319 319  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
320 320  
321 -
322 322  == 5.2 Application Key ==
323 323  
324 324  Feature: Get or Set the Application Key.
... ... @@ -335,7 +335,6 @@
335 335  )))
336 336  |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK
337 337  
338 -
339 339  == 5.3 Application Session Key ==
340 340  
341 341  Feature: Get or Set the Application Session Key.
... ... @@ -799,7 +799,7 @@
799 799  
800 800  )))
801 801  
802 -== 7.11 Receive Delay2 ==
793 +== 7.11Receive Delay2 ==
803 803  
804 804  Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
805 805  
... ... @@ -1004,8 +1004,6 @@
1004 1004  
1005 1005  (((
1006 1006  Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink.
1007 -
1008 -
1009 1009  )))
1010 1010  
1011 1011  == 7.21 Get or Set RXwindows2 timeout ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0