<
From version < 38.36 >
edited by Xiaoling
on 2022/05/31 09:11
To version < 38.19 >
edited by Xiaoling
on 2022/05/31 09:05
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,9 +22,8 @@
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 23  ** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 24  ** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
25 -** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
25 +** See use note for more serves [[Servers Note>>WebHome]](IoT LoRaWAN Server)
26 26  
27 -
28 28  = 3. Support End Node and firmware version =
29 29  
30 30  (% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
... ... @@ -98,8 +98,6 @@
98 98  )))
99 99  )))
100 100  
101 -
102 -
103 103  = 4. System Management Commands =
104 104  
105 105  == 4.1 Change Uplink Interval ==
... ... @@ -138,8 +138,6 @@
138 138  * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
139 139  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
140 140  
141 -
142 -
143 143  == 4.2 Reboot End Node ==
144 144  
145 145  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -335,7 +335,6 @@
335 335  )))
336 336  |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK
337 337  
338 -
339 339  == 5.3 Application Session Key ==
340 340  
341 341  Feature: Get or Set the Application Session Key.
... ... @@ -354,7 +354,6 @@
354 354  OK
355 355  )))
356 356  
357 -
358 358  == 5.4 Device Address ==
359 359  
360 360  Feature: Get or Set the Device Address.
... ... @@ -373,7 +373,6 @@
373 373  )))
374 374  |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK
375 375  
376 -
377 377  == 5.5 Device EUI ==
378 378  
379 379  Feature: Get or Set the Device EUI.
... ... @@ -392,7 +392,6 @@
392 392  OK
393 393  )))
394 394  
395 -
396 396  == 5.6 Network ID ==
397 397  
398 398  Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection)
... ... @@ -409,7 +409,6 @@
409 409  )))
410 410  |(% style="width:191px" %)AT+NWKID=A8 40 41 FF|(% style="width:153px" %)Set the Network ID.|(% style="width:101px" %)OK
411 411  
412 -
413 413  == 5.7 Network Session Key ==
414 414  
415 415  Feature: Get or Set the Network Session Key
... ... @@ -426,7 +426,6 @@
426 426  )))
427 427  |(% style="width:455px" %)AT+NWKSKEY=A8 40 41 FF FF 12 34 56 00 01 02 04 05 06 06 07|(% style="width:215px" %)Set the Network Session Key.|(% style="width:343px" %)OK
428 428  
429 -
430 430  = 6. Joining and sending date on LoRaWAN network =
431 431  
432 432  == 6.1 Confirm Mode ==
... ... @@ -455,7 +455,6 @@
455 455  * Example 1: Downlink Payload: 0501 ~/~/ Set AT+CFM=1
456 456  * Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0
457 457  
458 -
459 459  == 6.2 Confirm Status ==
460 460  
461 461  Feature: Get confirmation status of the last AT+SEND (0-1).
... ... @@ -471,7 +471,6 @@
471 471  OK
472 472  )))
473 473  
474 -
475 475  == 6.3 Join LoRa® Network ==
476 476  
477 477  Feature: Join network.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0