... ... @@ -20,11 +20,12 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
23 +** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]]
24 +** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]].
25 25  ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
26 26  
27 27  
28 +
28 28  = 3. Support End Node and firmware version =
29 29  
30 30  (% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
... ... @@ -99,7 +99,6 @@
99 99  )))
100 100  
101 101  
102 -
103 103  = 4. System Management Commands =
104 104  
105 105  == 4.1 Change Uplink Interval ==
... ... @@ -139,7 +139,6 @@
139 139  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
140 140  
141 141  
142 -
143 143  == 4.2 Reboot End Node ==
144 144  
145 145  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -301,6 +301,8 @@
301 301  OK
302 302  )))
303 303  
303 +
304 +
304 304  = 5. Keys, IDs and EUIs management =
305 305  
306 306  == 5.1 Application EUI ==
... ... @@ -319,6 +319,7 @@
319 319  )))
320 320  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
321 321  
323 +
322 322  == 5.2 Application Key ==
323 323  
324 324  Feature: Get or Set the Application Key.
... ... @@ -355,6 +355,7 @@
355 355  )))
356 356  
357 357  
360 +
358 358  == 5.4 Device Address ==
359 359  
360 360  Feature: Get or Set the Device Address.
... ... @@ -374,6 +374,7 @@
374 374  |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK
375 375  
376 376  
380 +
377 377  == 5.5 Device EUI ==
378 378  
379 379  Feature: Get or Set the Device EUI.
... ... @@ -393,6 +393,7 @@
393 393  )))
394 394  
395 395  
400 +
396 396  == 5.6 Network ID ==
397 397  
398 398  Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection)
... ... @@ -410,6 +410,7 @@
410 410  |(% style="width:191px" %)AT+NWKID=A8 40 41 FF|(% style="width:153px" %)Set the Network ID.|(% style="width:101px" %)OK
411 411  
412 412  
418 +
413 413  == 5.7 Network Session Key ==
414 414  
415 415  Feature: Get or Set the Network Session Key
... ... @@ -427,6 +427,7 @@
427 427  |(% style="width:455px" %)AT+NWKSKEY=A8 40 41 FF FF 12 34 56 00 01 02 04 05 06 06 07|(% style="width:215px" %)Set the Network Session Key.|(% style="width:343px" %)OK
428 428  
429 429  
436 +
430 430  = 6. Joining and sending date on LoRaWAN network =
431 431  
432 432  == 6.1 Confirm Mode ==
... ... @@ -455,7 +455,6 @@
455 455  * Example 1: Downlink Payload: 0501 ~/~/ Set AT+CFM=1
456 456  * Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0
457 457  
458 -
459 459  == 6.2 Confirm Status ==
460 460  
461 461  Feature: Get confirmation status of the last AT+SEND (0-1).
... ... @@ -471,7 +471,6 @@
471 471  OK
472 472  )))
473 473  
474 -
475 475  == 6.3 Join LoRa® Network ==
476 476  
477 477  Feature: Join network.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved