Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,11 +20,10 @@ 20 20 21 21 * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]] 22 22 * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command: 23 -** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]] 24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]] 23 +** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]] 24 +** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]]. 25 25 ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server) 26 26 27 - 28 28 = 3. Support End Node and firmware version = 29 29 30 30 (% border="1" style="background-color:#ffffcc; color:green; width:966px" %) ... ... @@ -98,8 +98,6 @@ 98 98 ))) 99 99 ))) 100 100 101 - 102 - 103 103 = 4. System Management Commands = 104 104 105 105 == 4.1 Change Uplink Interval == ... ... @@ -333,7 +333,6 @@ 333 333 ))) 334 334 |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK 335 335 336 - 337 337 == 5.3 Application Session Key == 338 338 339 339 Feature: Get or Set the Application Session Key. ... ... @@ -352,7 +352,6 @@ 352 352 OK 353 353 ))) 354 354 355 - 356 356 == 5.4 Device Address == 357 357 358 358 Feature: Get or Set the Device Address. ... ... @@ -371,7 +371,6 @@ 371 371 ))) 372 372 |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK 373 373 374 - 375 375 == 5.5 Device EUI == 376 376 377 377 Feature: Get or Set the Device EUI. ... ... @@ -390,7 +390,6 @@ 390 390 OK 391 391 ))) 392 392 393 - 394 394 == 5.6 Network ID == 395 395 396 396 Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection) ... ... @@ -407,7 +407,6 @@ 407 407 ))) 408 408 |(% style="width:191px" %)AT+NWKID=A8 40 41 FF|(% style="width:153px" %)Set the Network ID.|(% style="width:101px" %)OK 409 409 410 - 411 411 == 5.7 Network Session Key == 412 412 413 413 Feature: Get or Set the Network Session Key ... ... @@ -454,6 +454,7 @@ 454 454 * Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0 455 455 456 456 449 + 457 457 == 6.2 Confirm Status == 458 458 459 459 Feature: Get confirmation status of the last AT+SEND (0-1). ... ... @@ -470,6 +470,7 @@ 470 470 ))) 471 471 472 472 466 + 473 473 == 6.3 Join LoRa® Network == 474 474 475 475 Feature: Join network. ... ... @@ -487,6 +487,8 @@ 487 487 While Error in format, return AT_BUSY_ERROR 488 488 ))) 489 489 484 + 485 + 490 490 == 6.4 LoRa® Network Join Mode == 491 491 492 492 Feature: Get or Set the Network Join Mode. (0: ABP, 1: OTAA). ... ... @@ -515,6 +515,8 @@ 515 515 * **Example 1: **Downlink Payload: **2000** ~/~/ Set AT+NJM=O 516 516 * **Example 2:** Downlink Payload: **2001** ~/~/ Set AT+NJM=1 517 517 514 + 515 + 518 518 == 6.5 LoRa® Network Join Status == 519 519 520 520 Feature: LoRa® Network Join Status. ... ... @@ -530,6 +530,8 @@ 530 530 OK 531 531 ))) 532 532 531 + 532 + 533 533 == 6.6 Print Last Received Data in Raw Format == 534 534 535 535 Feature: Print Last Received Data in Raw Format<port:data>. ... ... @@ -545,6 +545,8 @@ 545 545 OK 546 546 ))) 547 547 548 + 549 + 548 548 == 6.7 Print Last Received Data in Binary Format == 549 549 550 550 Feature: Print Last Received Data in Binary Format<port:data>. ... ... @@ -560,6 +560,8 @@ 560 560 OK 561 561 ))) 562 562 565 + 566 + 563 563 == 6.8 Send Text Data == 564 564 565 565 Feature: Send Text Data<port:data>. ... ... @@ -579,6 +579,8 @@ 579 579 580 580 ))) 581 581 586 + 587 + 582 582 == 6.9 Send Hexadecimal Data == 583 583 584 584 Feature: Send hexadecimal data along with the application port.