From version < 38.35 >
edited by Xiaoling
on 2022/05/31 09:11
To version < 32.1 >
edited by Xiaoling
on 2022/05/27 18:01
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,11 +20,10 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
23 +** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]]
24 +** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]].
25 25  ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
26 26  
27 -
28 28  = 3. Support End Node and firmware version =
29 29  
30 30  (% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
... ... @@ -98,8 +98,6 @@
98 98  )))
99 99  )))
100 100  
101 -
102 -
103 103  = 4. System Management Commands =
104 104  
105 105  == 4.1 Change Uplink Interval ==
... ... @@ -333,7 +333,6 @@
333 333  )))
334 334  |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK
335 335  
336 -
337 337  == 5.3 Application Session Key ==
338 338  
339 339  Feature: Get or Set the Application Session Key.
... ... @@ -352,7 +352,6 @@
352 352  OK
353 353  )))
354 354  
355 -
356 356  == 5.4 Device Address ==
357 357  
358 358  Feature: Get or Set the Device Address.
... ... @@ -371,7 +371,6 @@
371 371  )))
372 372  |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK
373 373  
374 -
375 375  == 5.5 Device EUI ==
376 376  
377 377  Feature: Get or Set the Device EUI.
... ... @@ -390,7 +390,6 @@
390 390  OK
391 391  )))
392 392  
393 -
394 394  == 5.6 Network ID ==
395 395  
396 396  Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection)
... ... @@ -407,7 +407,6 @@
407 407  )))
408 408  |(% style="width:191px" %)AT+NWKID=A8 40 41 FF|(% style="width:153px" %)Set the Network ID.|(% style="width:101px" %)OK
409 409  
410 -
411 411  == 5.7 Network Session Key ==
412 412  
413 413  Feature: Get or Set the Network Session Key
... ... @@ -454,6 +454,7 @@
454 454  * Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0
455 455  
456 456  
449 +
457 457  == 6.2 Confirm Status ==
458 458  
459 459  Feature: Get confirmation status of the last AT+SEND (0-1).
... ... @@ -470,6 +470,7 @@
470 470  )))
471 471  
472 472  
466 +
473 473  == 6.3 Join LoRa® Network ==
474 474  
475 475  Feature: Join network.
... ... @@ -487,6 +487,8 @@
487 487  While Error in format, return AT_BUSY_ERROR
488 488  )))
489 489  
484 +
485 +
490 490  == 6.4 LoRa® Network Join Mode ==
491 491  
492 492  Feature: Get or Set the Network Join Mode. (0: ABP, 1: OTAA).
... ... @@ -515,6 +515,8 @@
515 515  * **Example 1: **Downlink Payload: **2000** ~/~/ Set AT+NJM=O
516 516  * **Example 2:** Downlink Payload: **2001** ~/~/ Set AT+NJM=1
517 517  
514 +
515 +
518 518  == 6.5 LoRa® Network Join Status ==
519 519  
520 520  Feature: LoRa® Network Join Status.
... ... @@ -530,6 +530,8 @@
530 530  OK
531 531  )))
532 532  
531 +
532 +
533 533  == 6.6 Print Last Received Data in Raw Format ==
534 534  
535 535  Feature: Print Last Received Data in Raw Format<port:data>.
... ... @@ -545,6 +545,8 @@
545 545  OK
546 546  )))
547 547  
548 +
549 +
548 548  == 6.7 Print Last Received Data in Binary Format ==
549 549  
550 550  Feature: Print Last Received Data in Binary Format<port:data>.
... ... @@ -560,6 +560,8 @@
560 560  OK
561 561  )))
562 562  
565 +
566 +
563 563  == 6.8 Send Text Data ==
564 564  
565 565  Feature: Send Text Data<port:data>.
... ... @@ -579,6 +579,8 @@
579 579  
580 580  )))
581 581  
586 +
587 +
582 582  == 6.9 Send Hexadecimal Data ==
583 583  
584 584  Feature: Send hexadecimal data along with the application port.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0