From version < 38.33 >
edited by Xiaoling
on 2022/05/31 09:10
To version < 38.46 >
edited by Xiaoling
on 2022/05/31 09:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -25,7 +25,6 @@
25 25  ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
26 26  
27 27  
28 -
29 29  = 3. Support End Node and firmware version =
30 30  
31 31  (% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
... ... @@ -100,6 +100,7 @@
100 100  )))
101 101  
102 102  
102 +
103 103  = 4. System Management Commands =
104 104  
105 105  == 4.1 Change Uplink Interval ==
... ... @@ -139,6 +139,7 @@
139 139  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
140 140  
141 141  
142 +
142 142  == 4.2 Reboot End Node ==
143 143  
144 144  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -301,6 +301,7 @@
301 301  )))
302 302  
303 303  
305 +
304 304  = 5. Keys, IDs and EUIs management =
305 305  
306 306  == 5.1 Application EUI ==
... ... @@ -320,6 +320,7 @@
320 320  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
321 321  
322 322  
325 +
323 323  == 5.2 Application Key ==
324 324  
325 325  Feature: Get or Set the Application Key.
... ... @@ -337,7 +337,6 @@
337 337  |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK
338 338  
339 339  
340 -
341 341  == 5.3 Application Session Key ==
342 342  
343 343  Feature: Get or Set the Application Session Key.
... ... @@ -357,7 +357,6 @@
357 357  )))
358 358  
359 359  
360 -
361 361  == 5.4 Device Address ==
362 362  
363 363  Feature: Get or Set the Device Address.
... ... @@ -377,7 +377,6 @@
377 377  |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK
378 378  
379 379  
380 -
381 381  == 5.5 Device EUI ==
382 382  
383 383  Feature: Get or Set the Device EUI.
... ... @@ -397,7 +397,6 @@
397 397  )))
398 398  
399 399  
400 -
401 401  == 5.6 Network ID ==
402 402  
403 403  Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection)
... ... @@ -415,7 +415,6 @@
415 415  |(% style="width:191px" %)AT+NWKID=A8 40 41 FF|(% style="width:153px" %)Set the Network ID.|(% style="width:101px" %)OK
416 416  
417 417  
418 -
419 419  == 5.7 Network Session Key ==
420 420  
421 421  Feature: Get or Set the Network Session Key
... ... @@ -433,7 +433,6 @@
433 433  |(% style="width:455px" %)AT+NWKSKEY=A8 40 41 FF FF 12 34 56 00 01 02 04 05 06 06 07|(% style="width:215px" %)Set the Network Session Key.|(% style="width:343px" %)OK
434 434  
435 435  
436 -
437 437  = 6. Joining and sending date on LoRaWAN network =
438 438  
439 439  == 6.1 Confirm Mode ==
... ... @@ -463,7 +463,6 @@
463 463  * Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0
464 464  
465 465  
466 -
467 467  == 6.2 Confirm Status ==
468 468  
469 469  Feature: Get confirmation status of the last AT+SEND (0-1).
... ... @@ -480,7 +480,6 @@
480 480  )))
481 481  
482 482  
483 -
484 484  == 6.3 Join LoRa® Network ==
485 485  
486 486  Feature: Join network.
... ... @@ -498,6 +498,8 @@
498 498  While Error in format, return AT_BUSY_ERROR
499 499  )))
500 500  
496 +
497 +
501 501  == 6.4 LoRa® Network Join Mode ==
502 502  
503 503  Feature: Get or Set the Network Join Mode. (0: ABP, 1: OTAA).
... ... @@ -526,6 +526,8 @@
526 526  * **Example 1: **Downlink Payload: **2000** ~/~/ Set AT+NJM=O
527 527  * **Example 2:** Downlink Payload: **2001** ~/~/ Set AT+NJM=1
528 528  
526 +
527 +
529 529  == 6.5 LoRa® Network Join Status ==
530 530  
531 531  Feature: LoRa® Network Join Status.
... ... @@ -541,6 +541,8 @@
541 541  OK
542 542  )))
543 543  
543 +
544 +
544 544  == 6.6 Print Last Received Data in Raw Format ==
545 545  
546 546  Feature: Print Last Received Data in Raw Format<port:data>.
... ... @@ -556,6 +556,8 @@
556 556  OK
557 557  )))
558 558  
560 +
561 +
559 559  == 6.7 Print Last Received Data in Binary Format ==
560 560  
561 561  Feature: Print Last Received Data in Binary Format<port:data>.
... ... @@ -571,6 +571,8 @@
571 571  OK
572 572  )))
573 573  
577 +
578 +
574 574  == 6.8 Send Text Data ==
575 575  
576 576  Feature: Send Text Data<port:data>.
... ... @@ -590,6 +590,8 @@
590 590  
591 591  )))
592 592  
598 +
599 +
593 593  == 6.9 Send Hexadecimal Data ==
594 594  
595 595  Feature: Send hexadecimal data along with the application port.
... ... @@ -608,6 +608,8 @@
608 608  
609 609  )))
610 610  
618 +
619 +
611 611  = 7. LoRaWAN network management =
612 612  
613 613  == 7.1 Adaptive Data Rate ==
... ... @@ -639,6 +639,8 @@
639 639  * **Example 1**: Downlink Payload: **2201** ~/~/ Set AT+ADR=1.
640 640  * **Example 2**: Downlink Payload: **2200FFFF** ~/~/ Set AT+ADR=0.
641 641  
651 +
652 +
642 642  == 7.2 LoRa® Class ==
643 643  
644 644  Feature: Get or Set the Device Class(Currently only support class A, class C).
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0