<
From version < 38.29 >
edited by Xiaoling
on 2022/05/31 09:09
To version < 33.1 >
edited by Xiaoling
on 2022/05/27 18:02
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,12 +20,10 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
23 +** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]]
24 +** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]].
25 25  ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
26 26  
27 -
28 -
29 29  = 3. Support End Node and firmware version =
30 30  
31 31  (% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
... ... @@ -99,7 +99,6 @@
99 99  )))
100 100  )))
101 101  
102 -
103 103  = 4. System Management Commands =
104 104  
105 105  == 4.1 Change Uplink Interval ==
... ... @@ -138,7 +138,6 @@
138 138  * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
139 139  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
140 140  
141 -
142 142  == 4.2 Reboot End Node ==
143 143  
144 144  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -301,6 +301,7 @@
301 301  )))
302 302  
303 303  
300 +
304 304  = 5. Keys, IDs and EUIs management =
305 305  
306 306  == 5.1 Application EUI ==
... ... @@ -320,6 +320,7 @@
320 320  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
321 321  
322 322  
320 +
323 323  == 5.2 Application Key ==
324 324  
325 325  Feature: Get or Set the Application Key.
... ... @@ -376,8 +376,6 @@
376 376  )))
377 377  |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK
378 378  
379 -
380 -
381 381  == 5.5 Device EUI ==
382 382  
383 383  Feature: Get or Set the Device EUI.
... ... @@ -396,8 +396,6 @@
396 396  OK
397 397  )))
398 398  
399 -
400 -
401 401  == 5.6 Network ID ==
402 402  
403 403  Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection)
... ... @@ -458,6 +458,7 @@
458 458  * Example 1: Downlink Payload: 0501 ~/~/ Set AT+CFM=1
459 459  * Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0
460 460  
455 +
461 461  == 6.2 Confirm Status ==
462 462  
463 463  Feature: Get confirmation status of the last AT+SEND (0-1).
... ... @@ -473,6 +473,7 @@
473 473  OK
474 474  )))
475 475  
471 +
476 476  == 6.3 Join LoRa® Network ==
477 477  
478 478  Feature: Join network.
... ... @@ -490,6 +490,7 @@
490 490  While Error in format, return AT_BUSY_ERROR
491 491  )))
492 492  
489 +
493 493  == 6.4 LoRa® Network Join Mode ==
494 494  
495 495  Feature: Get or Set the Network Join Mode. (0: ABP, 1: OTAA).
... ... @@ -518,6 +518,7 @@
518 518  * **Example 1: **Downlink Payload: **2000** ~/~/ Set AT+NJM=O
519 519  * **Example 2:** Downlink Payload: **2001** ~/~/ Set AT+NJM=1
520 520  
518 +
521 521  == 6.5 LoRa® Network Join Status ==
522 522  
523 523  Feature: LoRa® Network Join Status.
... ... @@ -533,6 +533,7 @@
533 533  OK
534 534  )))
535 535  
534 +
536 536  == 6.6 Print Last Received Data in Raw Format ==
537 537  
538 538  Feature: Print Last Received Data in Raw Format<port:data>.
... ... @@ -548,6 +548,7 @@
548 548  OK
549 549  )))
550 550  
550 +
551 551  == 6.7 Print Last Received Data in Binary Format ==
552 552  
553 553  Feature: Print Last Received Data in Binary Format<port:data>.
... ... @@ -563,6 +563,7 @@
563 563  OK
564 564  )))
565 565  
566 +
566 566  == 6.8 Send Text Data ==
567 567  
568 568  Feature: Send Text Data<port:data>.
... ... @@ -582,6 +582,7 @@
582 582  
583 583  )))
584 584  
586 +
585 585  == 6.9 Send Hexadecimal Data ==
586 586  
587 587  Feature: Send hexadecimal data along with the application port.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0