<
From version < 38.27 >
edited by Xiaoling
on 2022/05/31 09:09
To version < 20.1 >
edited by Xiaoling
on 2022/05/27 17:47
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,7 +3,6 @@
3 3  {{toc/}}
4 4  
5 5  
6 -
7 7  = 1. Introduction =
8 8  
9 9  Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
... ... @@ -20,8 +20,8 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
22 +** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]]
23 +** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]].
25 25  ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
26 26  
27 27  
... ... @@ -139,6 +139,7 @@
139 139  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
140 140  
141 141  
141 +
142 142  == 4.2 Reboot End Node ==
143 143  
144 144  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -301,6 +301,7 @@
301 301  )))
302 302  
303 303  
304 +
304 304  = 5. Keys, IDs and EUIs management =
305 305  
306 306  == 5.1 Application EUI ==
... ... @@ -320,6 +320,7 @@
320 320  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
321 321  
322 322  
324 +
323 323  == 5.2 Application Key ==
324 324  
325 325  Feature: Get or Set the Application Key.
... ... @@ -356,8 +356,6 @@
356 356  OK
357 357  )))
358 358  
359 -
360 -
361 361  == 5.4 Device Address ==
362 362  
363 363  Feature: Get or Set the Device Address.
... ... @@ -803,7 +803,7 @@
803 803  
804 804  )))
805 805  
806 -== 7.11 Receive Delay2 ==
806 +== 7.11Receive Delay2 ==
807 807  
808 808  Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
809 809  
... ... @@ -1008,8 +1008,6 @@
1008 1008  
1009 1009  (((
1010 1010  Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink.
1011 -
1012 -
1013 1013  )))
1014 1014  
1015 1015  == 7.21 Get or Set RXwindows2 timeout ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0