Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,6 @@ 3 3 {{toc/}} 4 4 5 5 6 - 7 7 = 1. Introduction = 8 8 9 9 Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands: ... ... @@ -20,10 +20,12 @@ 20 20 21 21 * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]] 22 22 * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command: 23 -** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]] 24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]] 22 +** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]] 23 +** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]]. 25 25 ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server) 26 26 26 + 27 + 27 27 = 3. Support End Node and firmware version = 28 28 29 29 (% border="1" style="background-color:#ffffcc; color:green; width:966px" %) ... ... @@ -98,7 +98,6 @@ 98 98 ))) 99 99 100 100 101 - 102 102 = 4. System Management Commands = 103 103 104 104 == 4.1 Change Uplink Interval == ... ... @@ -320,6 +320,8 @@ 320 320 ))) 321 321 |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK 322 322 323 + 324 + 323 323 == 5.2 Application Key == 324 324 325 325 Feature: Get or Set the Application Key. ... ... @@ -336,6 +336,8 @@ 336 336 ))) 337 337 |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK 338 338 341 + 342 + 339 339 == 5.3 Application Session Key == 340 340 341 341 Feature: Get or Set the Application Session Key. ... ... @@ -799,7 +799,7 @@ 799 799 800 800 ))) 801 801 802 -== 7.11 806 +== 7.11Receive Delay2 == 803 803 804 804 Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 805 805 ... ... @@ -1004,8 +1004,6 @@ 1004 1004 1005 1005 ((( 1006 1006 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 1007 - 1008 - 1009 1009 ))) 1010 1010 1011 1011 == 7.21 Get or Set RXwindows2 timeout ==