From version < 38.21 >
edited by Xiaoling
on 2022/05/31 09:07
To version < 19.5 >
edited by Xiaoling
on 2022/05/26 16:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,7 +3,6 @@
3 3  {{toc/}}
4 4  
5 5  
6 -
7 7  = 1. Introduction =
8 8  
9 9  Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
... ... @@ -20,9 +20,9 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
25 -** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
22 +** Use HEX format to send a downlink: [[TTN v3>>url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]]
23 +** Use Base64 format to send a downlink: [[Chirpstack>>url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]].
24 +** See use note for more serves [[Servers Note>>url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]]
26 26  
27 27  = 3. Support End Node and firmware version =
28 28  
... ... @@ -97,8 +97,6 @@
97 97  )))
98 98  )))
99 99  
100 -
101 -
102 102  = 4. System Management Commands =
103 103  
104 104  == 4.1 Change Uplink Interval ==
... ... @@ -172,8 +172,6 @@
172 172  
173 173  (((
174 174  If the downlink payload=**04FF**, the end node will reboot.
175 -
176 -
177 177  )))
178 178  
179 179  == 4.3 Reset to factory Default ==
... ... @@ -795,7 +795,7 @@
795 795  
796 796  )))
797 797  
798 -== 7.11 Receive Delay2 ==
793 +== 7.11Receive Delay2 ==
799 799  
800 800  Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
801 801  
... ... @@ -1000,8 +1000,6 @@
1000 1000  
1001 1001  (((
1002 1002  Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink.
1003 -
1004 -
1005 1005  )))
1006 1006  
1007 1007  == 7.21 Get or Set RXwindows2 timeout ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved