From version < 38.106 >
edited by Xiaoling
on 2022/06/01 11:54
To version < 19.5 >
edited by Xiaoling
on 2022/05/26 16:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,7 +3,6 @@
3 3  {{toc/}}
4 4  
5 5  
6 -
7 7  = 1. Introduction =
8 8  
9 9  Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
... ... @@ -20,12 +20,10 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
25 -** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
22 +** Use HEX format to send a downlink: [[TTN v3>>url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]]
23 +** Use Base64 format to send a downlink: [[Chirpstack>>url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]].
24 +** See use note for more serves [[Servers Note>>url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]]
26 26  
27 -
28 -
29 29  = 3. Support End Node and firmware version =
30 30  
31 31  (% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
... ... @@ -99,8 +99,6 @@
99 99  )))
100 100  )))
101 101  
102 -
103 -
104 104  = 4. System Management Commands =
105 105  
106 106  == 4.1 Change Uplink Interval ==
... ... @@ -139,8 +139,6 @@
139 139  * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
140 140  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
141 141  
142 -
143 -
144 144  == 4.2 Reboot End Node ==
145 145  
146 146  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -176,8 +176,6 @@
176 176  
177 177  (((
178 178  If the downlink payload=**04FF**, the end node will reboot.
179 -
180 -
181 181  )))
182 182  
183 183  == 4.3 Reset to factory Default ==
... ... @@ -302,8 +302,6 @@
302 302  OK
303 303  )))
304 304  
305 -
306 -
307 307  = 5. Keys, IDs and EUIs management =
308 308  
309 309  == 5.1 Application EUI ==
... ... @@ -322,8 +322,6 @@
322 322  )))
323 323  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
324 324  
325 -
326 -
327 327  == 5.2 Application Key ==
328 328  
329 329  Feature: Get or Set the Application Key.
... ... @@ -803,7 +803,7 @@
803 803  
804 804  )))
805 805  
806 -== 7.11 Receive Delay2 ==
793 +== 7.11Receive Delay2 ==
807 807  
808 808  Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
809 809  
... ... @@ -1008,8 +1008,6 @@
1008 1008  
1009 1009  (((
1010 1010  Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink.
1011 -
1012 -
1013 1013  )))
1014 1014  
1015 1015  == 7.21 Get or Set RXwindows2 timeout ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0