From version < 37.1 >
edited by Xiaoling
on 2022/05/27 18:07
To version < 38.28 >
edited by Xiaoling
on 2022/05/31 09:09
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,11 +20,12 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]].
23 +** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
24 +** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]]
25 25  ** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
26 26  
27 27  
28 +
28 28  = 3. Support End Node and firmware version =
29 29  
30 30  (% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
... ... @@ -99,7 +99,6 @@
99 99  )))
100 100  
101 101  
102 -
103 103  = 4. System Management Commands =
104 104  
105 105  == 4.1 Change Uplink Interval ==
... ... @@ -138,6 +138,7 @@
138 138  * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
139 139  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
140 140  
141 +
141 141  == 4.2 Reboot End Node ==
142 142  
143 143  Feature: Reboot End Node to perform a new OTAA or ABP Join.
... ... @@ -299,6 +299,7 @@
299 299  OK
300 300  )))
301 301  
303 +
302 302  = 5. Keys, IDs and EUIs management =
303 303  
304 304  == 5.1 Application EUI ==
... ... @@ -317,6 +317,7 @@
317 317  )))
318 318  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
319 319  
322 +
320 320  == 5.2 Application Key ==
321 321  
322 322  Feature: Get or Set the Application Key.
... ... @@ -333,6 +333,8 @@
333 333  )))
334 334  |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK
335 335  
339 +
340 +
336 336  == 5.3 Application Session Key ==
337 337  
338 338  Feature: Get or Set the Application Session Key.
... ... @@ -351,6 +351,8 @@
351 351  OK
352 352  )))
353 353  
359 +
360 +
354 354  == 5.4 Device Address ==
355 355  
356 356  Feature: Get or Set the Device Address.
... ... @@ -369,6 +369,8 @@
369 369  )))
370 370  |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK
371 371  
379 +
380 +
372 372  == 5.5 Device EUI ==
373 373  
374 374  Feature: Get or Set the Device EUI.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0