<
From version < 34.1 >
edited by Xiaoling
on 2022/05/27 18:02
To version < 19.5 >
edited by Xiaoling
on 2022/05/26 16:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,7 +3,6 @@
3 3  {{toc/}}
4 4  
5 5  
6 -
7 7  = 1. Introduction =
8 8  
9 9  Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
... ... @@ -20,9 +20,9 @@
20 20  
21 21  * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
22 22  * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
23 -** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]]
24 -** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]].
25 -** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
22 +** Use HEX format to send a downlink: [[TTN v3>>url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]]
23 +** Use Base64 format to send a downlink: [[Chirpstack>>url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]].
24 +** See use note for more serves [[Servers Note>>url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]]
26 26  
27 27  = 3. Support End Node and firmware version =
28 28  
... ... @@ -170,8 +170,6 @@
170 170  
171 171  (((
172 172  If the downlink payload=**04FF**, the end node will reboot.
173 -
174 -
175 175  )))
176 176  
177 177  == 4.3 Reset to factory Default ==
... ... @@ -296,7 +296,6 @@
296 296  OK
297 297  )))
298 298  
299 -
300 300  = 5. Keys, IDs and EUIs management =
301 301  
302 302  == 5.1 Application EUI ==
... ... @@ -315,7 +315,6 @@
315 315  )))
316 316  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
317 317  
318 -
319 319  == 5.2 Application Key ==
320 320  
321 321  Feature: Get or Set the Application Key.
... ... @@ -332,7 +332,6 @@
332 332  )))
333 333  |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK
334 334  
335 -
336 336  == 5.3 Application Session Key ==
337 337  
338 338  Feature: Get or Set the Application Session Key.
... ... @@ -351,7 +351,6 @@
351 351  OK
352 352  )))
353 353  
354 -
355 355  == 5.4 Device Address ==
356 356  
357 357  Feature: Get or Set the Device Address.
... ... @@ -370,8 +370,6 @@
370 370  )))
371 371  |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK
372 372  
373 -
374 -
375 375  == 5.5 Device EUI ==
376 376  
377 377  Feature: Get or Set the Device EUI.
... ... @@ -390,8 +390,6 @@
390 390  OK
391 391  )))
392 392  
393 -
394 -
395 395  == 5.6 Network ID ==
396 396  
397 397  Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection)
... ... @@ -801,7 +801,7 @@
801 801  
802 802  )))
803 803  
804 -== 7.11 Receive Delay2 ==
793 +== 7.11Receive Delay2 ==
805 805  
806 806  Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
807 807  
... ... @@ -1006,8 +1006,6 @@
1006 1006  
1007 1007  (((
1008 1008  Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink.
1009 -
1010 -
1011 1011  )))
1012 1012  
1013 1013  == 7.21 Get or Set RXwindows2 timeout ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0