Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,6 @@ 3 3 {{toc/}} 4 4 5 5 6 - 7 7 = 1. Introduction = 8 8 9 9 Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands: ... ... @@ -20,9 +20,9 @@ 20 20 21 21 * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]] 22 22 * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command: 23 -** Use HEX format to send a downlink: [[TTN v3>>doc :Main.Notes.WebHome]]24 -** Use Base64 format to send a downlink: [[Chirpstack>>doc :Main.Notes.WebHome]].25 -** See use note for more serves [[Servers Note>>doc :Main.WebHome]](IoT LoRaWANServer)22 +** Use HEX format to send a downlink: [[TTN v3>>url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]] 23 +** Use Base64 format to send a downlink: [[Chirpstack>>url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]]. 24 +** See use note for more serves [[Servers Note>>url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]] 26 26 27 27 = 3. Support End Node and firmware version = 28 28 ... ... @@ -170,8 +170,6 @@ 170 170 171 171 ((( 172 172 If the downlink payload=**04FF**, the end node will reboot. 173 - 174 - 175 175 ))) 176 176 177 177 == 4.3 Reset to factory Default == ... ... @@ -296,7 +296,6 @@ 296 296 OK 297 297 ))) 298 298 299 - 300 300 = 5. Keys, IDs and EUIs management = 301 301 302 302 == 5.1 Application EUI == ... ... @@ -315,7 +315,6 @@ 315 315 ))) 316 316 |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK 317 317 318 - 319 319 == 5.2 Application Key == 320 320 321 321 Feature: Get or Set the Application Key. ... ... @@ -332,7 +332,6 @@ 332 332 ))) 333 333 |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK 334 334 335 - 336 336 == 5.3 Application Session Key == 337 337 338 338 Feature: Get or Set the Application Session Key. ... ... @@ -351,7 +351,6 @@ 351 351 OK 352 352 ))) 353 353 354 - 355 355 == 5.4 Device Address == 356 356 357 357 Feature: Get or Set the Device Address. ... ... @@ -370,8 +370,6 @@ 370 370 ))) 371 371 |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK 372 372 373 - 374 - 375 375 == 5.5 Device EUI == 376 376 377 377 Feature: Get or Set the Device EUI. ... ... @@ -390,8 +390,6 @@ 390 390 OK 391 391 ))) 392 392 393 - 394 - 395 395 == 5.6 Network ID == 396 396 397 397 Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection) ... ... @@ -801,7 +801,7 @@ 801 801 802 802 ))) 803 803 804 -== 7.11 793 +== 7.11Receive Delay2 == 805 805 806 806 Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 807 807 ... ... @@ -1006,8 +1006,6 @@ 1006 1006 1007 1007 ((( 1008 1008 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 1009 - 1010 - 1011 1011 ))) 1012 1012 1013 1013 == 7.21 Get or Set RXwindows2 timeout ==