Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,6 @@ 3 3 {{toc/}} 4 4 5 5 6 - 7 7 = 1. Introduction = 8 8 9 9 Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands: ... ... @@ -20,9 +20,9 @@ 20 20 21 21 * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]] 22 22 * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command: 23 -** Use HEX format to send a downlink: [[TTN v3>>doc :Main.Notes.WebHome]]24 -** Use Base64 format to send a downlink: [[Chirpstack>>doc :Main.Notes.WebHome]].25 -** See use note for more serves [[Servers Note>>doc :Main.WebHome]](IoT LoRaWANServer)22 +** Use HEX format to send a downlink: [[TTN v3>>url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]] 23 +** Use Base64 format to send a downlink: [[Chirpstack>>url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]]. 24 +** See use note for more serves [[Servers Note>>url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]] 26 26 27 27 = 3. Support End Node and firmware version = 28 28 ... ... @@ -135,7 +135,6 @@ 135 135 * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds 136 136 * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds 137 137 138 - 139 139 == 4.2 Reboot End Node == 140 140 141 141 Feature: Reboot End Node to perform a new OTAA or ABP Join. ... ... @@ -171,8 +171,6 @@ 171 171 172 172 ((( 173 173 If the downlink payload=**04FF**, the end node will reboot. 174 - 175 - 176 176 ))) 177 177 178 178 == 4.3 Reset to factory Default == ... ... @@ -297,8 +297,6 @@ 297 297 OK 298 298 ))) 299 299 300 - 301 - 302 302 = 5. Keys, IDs and EUIs management = 303 303 304 304 == 5.1 Application EUI == ... ... @@ -317,8 +317,6 @@ 317 317 ))) 318 318 |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK 319 319 320 - 321 - 322 322 == 5.2 Application Key == 323 323 324 324 Feature: Get or Set the Application Key. ... ... @@ -335,8 +335,6 @@ 335 335 ))) 336 336 |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK 337 337 338 - 339 - 340 340 == 5.3 Application Session Key == 341 341 342 342 Feature: Get or Set the Application Session Key. ... ... @@ -800,7 +800,7 @@ 800 800 801 801 ))) 802 802 803 -== 7.11 793 +== 7.11Receive Delay2 == 804 804 805 805 Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 806 806 ... ... @@ -1005,8 +1005,6 @@ 1005 1005 1006 1006 ((( 1007 1007 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 1008 - 1009 - 1010 1010 ))) 1011 1011 1012 1012 == 7.21 Get or Set RXwindows2 timeout == ... ... @@ -1108,6 +1108,6 @@ 1108 1108 1109 1109 Same as: 1110 1110 1111 -* AT+ADR=0 ||anchor="H7.1AdaptiveDataRate"]]1112 -* AT+DR=5 ||anchor="H7.4DataRate"]]1113 -* AT+TXP=0 ||anchor="H7.14TransmitPower"]]1099 +* AT+ADR=0 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.1AdaptiveDataRate]] 1100 +* AT+DR=5 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]] 1101 +* AT+TXP=0 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.14TransmitPower]]