Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,7 @@ 3 3 {{toc/}} 4 4 5 5 6 + 6 6 = 1. Introduction = 7 7 8 8 Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands: ... ... @@ -19,28 +19,28 @@ 19 19 20 20 * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]] 21 21 * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command: 22 -** Use HEX format to send a downlink: [[TTN v3>> url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]]23 -** Use Base64 format to send a downlink: [[Chirpstack>> url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]].24 -** See use note for more serves [[Servers Note>> url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]]23 +** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]] 24 +** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]] 25 +** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server) 25 25 26 26 = 3. Support End Node and firmware version = 27 27 28 -(% border="1" style="background-color:#ffffcc; border:1;color:green; width:995.222px" %)29 -|=(% colspan="3" style="width: 9 92px;" %)(((29 +(% border="1" style="background-color:#ffffcc; color:green; width:966px" %) 30 +|=(% colspan="3" style="width: 963px;" %)((( 30 30 Dragino STM32 base hardware Firmware / LoRaWAN stack list 31 31 ))) 32 32 |(% style="width:187px" %)((( 33 33 **Model** 34 -)))|(% style="width:3 49px" %)(((35 +)))|(% style="width:330px" %)((( 35 35 **Description** 36 -)))|(% style="width:45 3px" %)(((37 +)))|(% style="width:445px" %)((( 37 37 **Firmware Version <~-~-> Stack Version** 38 38 ))) 39 39 |(% style="width:187px" %)((( 40 40 [[LSN50-v1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/128-lsn50.html]], [[LSN50-V2>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/155-lsn50-v2.html]], 41 -)))|(% style="width:3 49px" %)(((42 +)))|(% style="width:330px" %)((( 42 42 Open Source Generic LoRaWAN Sensor Node 43 -)))|(% style="width:45 3px" %)(((44 +)))|(% style="width:445px" %)((( 44 44 ((( 45 45 LSN50 v1.6.0 <~-~-> DR-LWS-003; 46 46 ))) ... ... @@ -53,9 +53,9 @@ 53 53 ))) 54 54 |(% style="width:187px" %)((( 55 55 [[LGT92>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/142-lgt-92.html]], 56 -)))|(% style="width:3 49px" %)(((57 +)))|(% style="width:330px" %)((( 57 57 LoRaWAN GPS Tracker 58 -)))|(% style="width:45 3px" %)(((59 +)))|(% style="width:445px" %)((( 59 59 ((( 60 60 LGT92 v1.6.3 <~-~-> DR-LWS-003; 61 61 ))) ... ... @@ -68,23 +68,23 @@ 68 68 ))) 69 69 |(% style="width:187px" %)((( 70 70 [[LBT1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/165-lbt1.html]], 71 -)))|(% style="width:3 49px" %)(((72 +)))|(% style="width:330px" %)((( 72 72 LoRaWAN BLE Indoor Tracker 73 -)))|(% style="width:45 3px" %)(((74 +)))|(% style="width:445px" %)((( 74 74 LBT1 v1.0 <~-~-> DR-LWS-005; 75 75 ))) 76 76 |(% style="width:187px" %)((( 77 77 [[RS485-LN>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/154-rs485-ln.html]], 78 -)))|(% style="width:3 49px" %)(((79 +)))|(% style="width:330px" %)((( 79 79 LoRaWAN RS485 Modbus Converter 80 -)))|(% style="width:45 3px" %)(((81 +)))|(% style="width:445px" %)((( 81 81 RS485-LN v1.3 <~-~-> DR-LWS-005; 82 82 ))) 83 83 |(% style="width:187px" %)((( 84 84 [[LHT65>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/151-lht65.html]], 85 -)))|(% style="width:3 49px" %)(((86 +)))|(% style="width:330px" %)((( 86 86 LoRaWAN Temperature & Humidity Sensor 87 -)))|(% style="width:45 3px" %)(((88 +)))|(% style="width:445px" %)((( 88 88 ((( 89 89 LHT65 v1.7 <~-~-> DR-LWS-003; 90 90 ))) ... ... @@ -169,6 +169,8 @@ 169 169 170 170 ((( 171 171 If the downlink payload=**04FF**, the end node will reboot. 173 + 174 + 172 172 ))) 173 173 174 174 == 4.3 Reset to factory Default == ... ... @@ -217,10 +217,10 @@ 217 217 **AT Command: AT+VER** 218 218 {{/info}} 219 219 220 -(% border="1" style="background-color:#ffffcc; color:green" %) 221 -|=(% colspan="3" %)AT+VER: Image Version and Frequency Band 222 -|**Command Example**|**Function**|**Response** 223 -|AT+VER=?|Show Image version and Frequency Band|((( 223 +(% border="1" style="background-color:#ffffcc; color:green; width:586px" %) 224 +|=(% colspan="3" style="width: 583px;" %)AT+VER: Image Version and Frequency Band 225 +|(% style="width:170px" %)**Command Example**|(% style="width:300px" %)**Function**|(% style="width:113px" %)**Response** 226 +|(% style="width:170px" %)AT+VER=?|(% style="width:300px" %)Show Image version and Frequency Band|(% style="width:113px" %)((( 224 224 1.3 EU868 225 225 226 226 OK ... ... @@ -417,6 +417,8 @@ 417 417 418 418 == 6.1 Confirm Mode == 419 419 423 +=== AT+CFM command before DR-LWS007 software stack === 424 + 420 420 Feature: Get or Set the confirmation mode (0-1). 421 421 422 422 {{info}} ... ... @@ -441,6 +441,56 @@ 441 441 * Example 1: Downlink Payload: 0501 ~/~/ Set AT+CFM=1 442 442 * Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0 443 443 449 + 450 +=== AT+CFM command since DR-LWS007 software stack === 451 + 452 +{{info}} 453 +**AT Command: AT+CFM** 454 +{{/info}} 455 + 456 +(% border="1" style="background-color:#ffffcc; color:green; width:710.222px" %) 457 +|=(% colspan="3" style="width: 707px;" %)AT+CFM 458 +|(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response** 459 +|(% style="width:160px" %)((( 460 +AT+CFM=1,0,0 461 + 462 +value1 463 +)))|(% style="width:198px" %)confirmed uplink|(% style="width:349px" %)((( 464 +1 465 + 466 +OK 467 +))) 468 +|(% style="width:160px" %)((( 469 +AT+CFM=0,?,0 470 + 471 +value2 472 +)))|(% style="width:198px" %)set max retry , range: 0 ~~ 7|(% style="width:349px" %)((( 473 +0~~7 474 + 475 +OK 476 +))) 477 +|(% style="width:160px" %)((( 478 +AT+CFM=0,0,1 479 + 480 +value3 481 +)))|(% style="width:198px" %)uplink fcnt increase by 1 for each retry|(% style="width:349px" %)((( 482 +1 483 + 484 +OK 485 +))) 486 + 487 +{{info}} 488 +**Downlink Command: 0x05** 489 +{{/info}} 490 + 491 +Format: Command Code (0x05) followed by 2 bytes mode value. 492 + 493 +If the downlink payload=05010101, it means set end node to use confirm mode, while type code is 05. 494 + 495 +* Example 1: Downlink Payload: 05010101 ~/~/ Set AT+CFM=1,1,1 496 +* Example 2: Downlink Payload: 05000700 ~/~/ Set AT+CFM=0,7,0 497 + 498 + 444 444 == 6.2 Confirm Status == 445 445 446 446 Feature: Get confirmation status of the last AT+SEND (0-1). ... ... @@ -790,7 +790,7 @@ 790 790 791 791 ))) 792 792 793 -== 7.11Receive Delay2 == 848 +== 7.11 Receive Delay2 == 794 794 795 795 Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 796 796 ... ... @@ -991,10 +991,12 @@ 991 991 **AT+RX1TWO** is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 992 992 ))) 993 993 994 -[[image:image-2022051 1120050-1.png]]1049 +[[image:image-20220526162535-1.png]] 995 995 996 996 ((( 997 997 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 1053 + 1054 + 998 998 ))) 999 999 1000 1000 == 7.21 Get or Set RXwindows2 timeout == ... ... @@ -1081,6 +1081,101 @@ 1081 1081 * **Example 1**: Downlink Payload: **2101** ~/~/ set packet receiving response level to 1 1082 1082 * **Example 2**: Downlink Payload: **2102** ~/~/ set packet receiving response level to 2 1083 1083 1141 + 1142 +== 7.24 Controls NBTrans in unconfirmed uplink mode(LWS007 NBTrans:Set retransmission packets) == 1143 + 1144 +{{info}} 1145 +**AT Command: AT+SETMAXNBTRANS ** 1146 +{{/info}} 1147 + 1148 +(% border="1" style="background-color:#ffffcc; color:green; width:536.222px" %) 1149 +|=(% colspan="3" style="width: 533px;" %)AT+**SETMAXNBTRANS** 1150 +|(% style="width:160px" %)**Command Example**|(% style="width:263px" %)**Function**|(% style="width:109px" %)**Response** 1151 +|(% style="width:160px" %)**AT+SETMAXNBTRANS=1,0**|(% style="width:263px" %)Value1: set the maximum NBTrans.|(% style="width:109px" %)1((( 1152 +OK 1153 +))) 1154 +|(% style="width:160px" %)**AT+SETMAXNBTRANS=?,1**|(% style="width:263px" %)value2: 0: uplink fcnt doesn't change for each NBTrans; 1: uplink fcnt increase by 1 for each NBTrans.|(% style="width:109px" %)((( 1155 +1 1156 + 1157 +OK 1158 +))) 1159 + 1160 +{{info}} 1161 +**Downlink Command: 0x33** 1162 +{{/info}} 1163 + 1164 +Format: Command Code (0x33) followed by 2 bytes mode value. 1165 + 1166 +If the downlink payload=330100, it means set end node to use confirm mode, while type code is 33. 1167 + 1168 +* Example 1: Downlink Payload: 330100 ~/~/ Set AT+SETMAXNBTRANS=1,0 1169 +* Example 2: Downlink Payload: 330201 ~/~/ Set AT+SETMAXNBTRANS=2,1 1170 + 1171 +== 7.25 Device offline rejoining (LWS007) == 1172 + 1173 +{{info}} 1174 +**AT Command: AT+DDETECT** 1175 +{{/info}} 1176 + 1177 +(% border="1" style="background-color:#ffffcc; color:green; width:710.222px" %) 1178 +|=(% colspan="3" style="width: 707px;" %)AT+**DDETECT** 1179 +|(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response** 1180 +|(% style="width:160px" %)((( 1181 +AT+DDETECT=1,1440,2880 1182 + 1183 +value1 1184 +)))|(% style="width:198px" %)Enable online detect|(% style="width:349px" %)((( 1185 +1 1186 + 1187 +OK 1188 +))) 1189 +|(% style="width:160px" %)((( 1190 +AT+DDETECT=1,?,2880 1191 + 1192 +value2 1193 +)))|(% style="width:198px" %)Online detection packet sending time|(% style="width:349px" %)((( 1194 + 1195 + 1196 +OK 1197 +))) 1198 +|(% style="width:160px" %)((( 1199 +AT+DDETECT=1,1440,? 1200 + 1201 +value3 1202 +)))|(% style="width:198px" %)Process rejoin|(% style="width:349px" %)((( 1203 + 1204 + 1205 +OK 1206 +))) 1207 + 1208 +{{info}} 1209 +**Downlink Command: 0x33** 1210 +{{/info}} 1211 + 1212 +Format: Command Code (0x32) followed by 2 bytes mode value. 1213 + 1214 +If the downlink payload=320105A00B40, it means set end node to use confirm mode, while type code is 33. 1215 + 1216 +* Example 1: Downlink Payload: 320105A00B40 ~/~/ Set AT+DDETECT=1,1440,2880 1217 + 1218 +== 7.26 Request the server to send an ACK == 1219 + 1220 +{{info}} 1221 +**AT Command: AT+PNACKMD** 1222 +{{/info}} 1223 + 1224 +(% border="1" style="background-color:#ffffcc; color:green; width:536.222px" %) 1225 +|=(% colspan="3" style="width: 533px;" %)**AT+PNACKMD** 1226 +|(% style="width:160px" %)**Command Example**|(% style="width:263px" %)**Function**|(% style="width:109px" %)**Response** 1227 +|(% style="width:160px" %)**AT+PNACKMD=1**|(% style="width:263px" %)If the node uploads the ACK as confirm, it will request the server to send an ACK. If the server ack is not received, the node will upload the packets that have not received the ACK the next time it receives the ACK|(% style="width:109px" %)1((( 1228 +OK 1229 +))) 1230 +|(% style="width:160px" %)**AT+PNACKMD=0**|(% style="width:263px" %)off request the server to send an ACK|(% style="width:109px" %)((( 1231 +0 1232 + 1233 +OK 1234 +))) 1235 + 1084 1084 = 8. AT Commands Combination = 1085 1085 1086 1086 == 8.1 Set a fix RX2DR for downlink window == ... ... @@ -1096,6 +1096,7 @@ 1096 1096 1097 1097 Same as: 1098 1098 1099 -* AT+ADR=0 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.1AdaptiveDataRate]] 1100 -* AT+DR=5 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]] 1101 -* AT+TXP=0 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.14TransmitPower]] 1251 +* AT+ADR=0 [[Reference>>||anchor="H7.1AdaptiveDataRate"]] 1252 +* AT+DR=5 [[Reference>>||anchor="H7.4DataRate"]] 1253 +* AT+TXP=0 [[Reference>>||anchor="H7.14TransmitPower"]] 1254 +~)~)~)
- image-20220526162535-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +149.4 KB - Content