Page properties
Content
... ... @@ -10,10 +10,8 @@
10 10  * **Common Commands:** They should be available for each sensor, such as: change uplink interval, reset device.
11 11  * **Sensor Related Commands:** Only for special sensor, such as control relay, poll RS485 device.
12 12  
13 -(((
14 14  **This page shows the common commands since Dragino LoRaWAN stack DR-LWS-005. Make sure the end node support stack higher than DR-LWS-005 before checking this page.**
15 15  
16 -)))
17 17  
18 18  = 2. How to use AT Commands or Downlink command =
19 19  
... ... @@ -26,75 +26,19 @@
26 26  = 3. Support End Node and firmware version =
27 27  
28 28  (% border="1" style="background-color:#ffffcc; border:1; color:green; width:995.222px" %)
29 -|=(% colspan="3" style="width: 992px;" %)(((
30 -Dragino STM32 base hardware Firmware / LoRaWAN stack list
31 -)))
32 -|(% style="width:187px" %)(((
33 -**Model**
34 -)))|(% style="width:349px" %)(((
35 -**Description**
36 -)))|(% style="width:453px" %)(((
37 -**Firmware Version <~-~-> Stack Version**
38 -)))
39 -|(% style="width:187px" %)(((
40 -[[LSN50-v1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/128-lsn50.html]], [[LSN50-V2>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/155-lsn50-v2.html]],
41 -)))|(% style="width:349px" %)(((
42 -Open Source Generic LoRaWAN Sensor Node
43 -)))|(% style="width:453px" %)(((
44 -(((
45 -LSN50 v1.6.0 <~-~-> DR-LWS-003;
46 -)))
47 -
48 -(((
49 -(((
27 +|=(% colspan="3" style="width: 992px;" %)Dragino STM32 base hardware Firmware / LoRaWAN stack list
28 +|(% style="width:187px" %)**Model**|(% style="width:349px" %)**Description**|(% style="width:453px" %)**Firmware Version <~-~-> Stack Version**
29 +|(% style="width:187px" %)[[LSN50-v1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/128-lsn50.html]], [[LSN50-V2>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/155-lsn50-v2.html]],|(% style="width:349px" %)Open Source Generic LoRaWAN Sensor Node|(% style="width:453px" %)LSN50 v1.6.0 <~-~-> DR-LWS-003;(((
50 50  LSN50 v1.7.0 <~-~-> DR-LWS-005; ~-~-> Support since this version
51 51  )))
52 -)))
53 -)))
54 -|(% style="width:187px" %)(((
55 -[[LGT92>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/142-lgt-92.html]],
56 -)))|(% style="width:349px" %)(((
57 -LoRaWAN GPS Tracker
58 -)))|(% style="width:453px" %)(((
59 -(((
60 -LGT92 v1.6.3 <~-~-> DR-LWS-003;
61 -)))
62 -
63 -(((
64 -(((
32 +|(% style="width:187px" %)[[LGT92>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/142-lgt-92.html]],|(% style="width:349px" %)LoRaWAN GPS Tracker|(% style="width:453px" %)LGT92 v1.6.3 <~-~-> DR-LWS-003;(((
65 65  LGT92 v1.6.4 <~-~-> DR-LWS-005;~-~-> Support since this version
66 66  )))
67 -)))
68 -)))
69 -|(% style="width:187px" %)(((
70 -[[LBT1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/165-lbt1.html]],
71 -)))|(% style="width:349px" %)(((
72 -LoRaWAN BLE Indoor Tracker
73 -)))|(% style="width:453px" %)(((
74 -LBT1 v1.0 <~-~-> DR-LWS-005;
75 -)))
76 -|(% style="width:187px" %)(((
77 -[[RS485-LN>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/154-rs485-ln.html]],
78 -)))|(% style="width:349px" %)(((
79 -LoRaWAN RS485 Modbus Converter
80 -)))|(% style="width:453px" %)(((
81 -RS485-LN v1.3 <~-~-> DR-LWS-005;
82 -)))
83 -|(% style="width:187px" %)(((
84 -[[LHT65>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/151-lht65.html]],
85 -)))|(% style="width:349px" %)(((
86 -LoRaWAN Temperature & Humidity Sensor
87 -)))|(% style="width:453px" %)(((
88 -(((
89 -LHT65 v1.7 <~-~-> DR-LWS-003;
90 -)))
91 -
92 -(((
93 -(((
35 +|(% style="width:187px" %)[[LBT1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/165-lbt1.html]],|(% style="width:349px" %)LoRaWAN BLE Indoor Tracker|(% style="width:453px" %)LBT1 v1.0 <~-~-> DR-LWS-005;
36 +|(% style="width:187px" %)[[RS485-LN>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/154-rs485-ln.html]],|(% style="width:349px" %)LoRaWAN RS485 Modbus Converter|(% style="width:453px" %)RS485-LN v1.3 <~-~-> DR-LWS-005;
37 +|(% style="width:187px" %)[[LHT65>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/151-lht65.html]],|(% style="width:349px" %)LoRaWAN Temperature & Humidity Sensor|(% style="width:453px" %)LHT65 v1.7 <~-~-> DR-LWS-003;(((
94 94  LHT65 v1.8.0 <~-~-> DR-LWS-005;~-~-> Support since this version
95 95  )))
96 -)))
97 -)))
98 98  
99 99  = 4. System Management Commands =
100 100  
... ... @@ -123,13 +123,9 @@
123 123  **Downlink Command: 0x01**
124 124  {{/info}}
125 125  
126 -(((
127 127  Format: Command Code (0x01) followed by 3 bytes time value.
128 -)))
129 129  
130 -(((
131 131  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
132 -)))
133 133  
134 134  * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
135 135  * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
... ... @@ -224,9 +224,7 @@
224 224  
225 225  Downlink Format: 0x26
226 226  
227 -(((
228 228  Device will reply with firmware version info, device info. frequency band info. detail please check device user manual. Total 5 bytes Example: If device is of firmware version 1.1.0 Upload: xx ~-~- yy ~-~- zz ~-~- 110 total 5 bytes
229 -)))
230 230  
231 231  **xx: Software Type:**
232 232  
... ... @@ -971,15 +971,11 @@
971 971  )))
972 972  |(% style="width:163px" %)AT+RX1WTO=60|(% style="width:201px" %)Set RXwindows1 timeout|(% style="width:93px" %)OK
973 973  
974 -(((
975 -**AT+RX1TWO** is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph.
976 -)))
910 +AT+RX1TWO is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph.
977 977  
978 978  [[image:image-20220511120050-1.png]]
979 979  
980 -(((
981 981  Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink.
982 -)))
983 983  
984 984  == 7.21 Get or Set RXwindows2 timeout ==