Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,4 @@ 1 -Contens 1 + **Contents:** 2 2 3 3 {{toc/}} 4 4 ... ... @@ -19,28 +19,30 @@ 19 19 20 20 * For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]] 21 21 * For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command: 22 -** Use HEX format to send a downlink: [[TTN v3>> url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]]23 -** Use Base64 format to send a downlink: [[Chirpstack>> url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]].24 -** See use note for more serves [[Servers Note>> url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]]22 +** Use HEX format to send a downlink: [[TTN v3>>doc:Main.Notes for TTN.WebHome]] 23 +** Use Base64 format to send a downlink: [[Chirpstack>>doc:Main.Notes for ChirpStack.WebHome]]. 24 +** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server) 25 25 26 + 27 + 26 26 = 3. Support End Node and firmware version = 27 27 28 -(% border="1" style="background-color:#ffffcc; border:1;color:green; width:995.222px" %)29 -|=(% colspan="3" style="width: 9 92px;" %)(((30 +(% border="1" style="background-color:#ffffcc; color:green; width:966px" %) 31 +|=(% colspan="3" style="width: 963px;" %)((( 30 30 Dragino STM32 base hardware Firmware / LoRaWAN stack list 31 31 ))) 32 32 |(% style="width:187px" %)((( 33 33 **Model** 34 -)))|(% style="width:3 49px" %)(((36 +)))|(% style="width:330px" %)((( 35 35 **Description** 36 -)))|(% style="width:45 3px" %)(((38 +)))|(% style="width:445px" %)((( 37 37 **Firmware Version <~-~-> Stack Version** 38 38 ))) 39 39 |(% style="width:187px" %)((( 40 40 [[LSN50-v1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/128-lsn50.html]], [[LSN50-V2>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/155-lsn50-v2.html]], 41 -)))|(% style="width:3 49px" %)(((43 +)))|(% style="width:330px" %)((( 42 42 Open Source Generic LoRaWAN Sensor Node 43 -)))|(% style="width:45 3px" %)(((45 +)))|(% style="width:445px" %)((( 44 44 ((( 45 45 LSN50 v1.6.0 <~-~-> DR-LWS-003; 46 46 ))) ... ... @@ -53,9 +53,9 @@ 53 53 ))) 54 54 |(% style="width:187px" %)((( 55 55 [[LGT92>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/142-lgt-92.html]], 56 -)))|(% style="width:3 49px" %)(((58 +)))|(% style="width:330px" %)((( 57 57 LoRaWAN GPS Tracker 58 -)))|(% style="width:45 3px" %)(((60 +)))|(% style="width:445px" %)((( 59 59 ((( 60 60 LGT92 v1.6.3 <~-~-> DR-LWS-003; 61 61 ))) ... ... @@ -68,23 +68,23 @@ 68 68 ))) 69 69 |(% style="width:187px" %)((( 70 70 [[LBT1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/165-lbt1.html]], 71 -)))|(% style="width:3 49px" %)(((73 +)))|(% style="width:330px" %)((( 72 72 LoRaWAN BLE Indoor Tracker 73 -)))|(% style="width:45 3px" %)(((75 +)))|(% style="width:445px" %)((( 74 74 LBT1 v1.0 <~-~-> DR-LWS-005; 75 75 ))) 76 76 |(% style="width:187px" %)((( 77 77 [[RS485-LN>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/154-rs485-ln.html]], 78 -)))|(% style="width:3 49px" %)(((80 +)))|(% style="width:330px" %)((( 79 79 LoRaWAN RS485 Modbus Converter 80 -)))|(% style="width:45 3px" %)(((82 +)))|(% style="width:445px" %)((( 81 81 RS485-LN v1.3 <~-~-> DR-LWS-005; 82 82 ))) 83 83 |(% style="width:187px" %)((( 84 84 [[LHT65>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/151-lht65.html]], 85 -)))|(% style="width:3 49px" %)(((87 +)))|(% style="width:330px" %)((( 86 86 LoRaWAN Temperature & Humidity Sensor 87 -)))|(% style="width:45 3px" %)(((89 +)))|(% style="width:445px" %)((( 88 88 ((( 89 89 LHT65 v1.7 <~-~-> DR-LWS-003; 90 90 ))) ... ... @@ -96,6 +96,7 @@ 96 96 ))) 97 97 ))) 98 98 101 + 99 99 = 4. System Management Commands = 100 100 101 101 == 4.1 Change Uplink Interval == ... ... @@ -123,7 +123,9 @@ 123 123 **Downlink Command: 0x01** 124 124 {{/info}} 125 125 129 +((( 126 126 Format: Command Code (0x01) followed by 3 bytes time value. 131 +))) 127 127 128 128 ((( 129 129 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. ... ... @@ -132,6 +132,8 @@ 132 132 * **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds 133 133 * **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds 134 134 140 + 141 + 135 135 == 4.2 Reboot End Node == 136 136 137 137 Feature: Reboot End Node to perform a new OTAA or ABP Join. ... ... @@ -161,10 +161,16 @@ 161 161 **Downlink Command: 0x04** 162 162 {{/info}} 163 163 171 +((( 164 164 Format: Command Code (0x04) followed by FF. 173 +))) 165 165 175 +((( 166 166 If the downlink payload=**04FF**, the end node will reboot. 167 167 178 + 179 +))) 180 + 168 168 == 4.3 Reset to factory Default == 169 169 170 170 Feature: Reset the parameters to Factory Default, factory default value depends on the firmware settings, the OTAA and ABP keys will reserve after this command. ... ... @@ -194,9 +194,13 @@ 194 194 **Downlink Command: 0x04** 195 195 {{/info}} 196 196 210 +((( 197 197 Format: Command Code (0x04) followed by FE. 212 +))) 198 198 214 +((( 199 199 If the downlink payload=**04FE**, Reset Parameters to Factory Default, Keys Reserve. 216 +))) 200 200 201 201 202 202 == 4.4 Show Firmware Version == ... ... @@ -207,10 +207,10 @@ 207 207 **AT Command: AT+VER** 208 208 {{/info}} 209 209 210 -(% border="1" style="background-color:#ffffcc; color:green" %) 211 -|=(% colspan="3" %)AT+VER: Image Version and Frequency Band 212 -|**Command Example**|**Function**|**Response** 213 -|AT+VER=?|Show Image version and Frequency Band|((( 227 +(% border="1" style="background-color:#ffffcc; color:green; width:586px" %) 228 +|=(% colspan="3" style="width: 583px;" %)AT+VER: Image Version and Frequency Band 229 +|(% style="width:170px" %)**Command Example**|(% style="width:300px" %)**Function**|(% style="width:113px" %)**Response** 230 +|(% style="width:170px" %)AT+VER=?|(% style="width:300px" %)Show Image version and Frequency Band|(% style="width:113px" %)((( 214 214 1.3 EU868 215 215 216 216 OK ... ... @@ -220,19 +220,25 @@ 220 220 **Downlink Command: 0x26 (Valid in 006 stack)** 221 221 {{/info}} 222 222 240 +((( 223 223 Downlink Format: 0x26 242 +))) 224 224 225 225 ((( 226 226 Device will reply with firmware version info, device info. frequency band info. detail please check device user manual. Total 5 bytes Example: If device is of firmware version 1.1.0 Upload: xx ~-~- yy ~-~- zz ~-~- 110 total 5 bytes 227 227 ))) 228 228 248 +((( 229 229 **xx: Software Type:** 250 +))) 230 230 231 231 * 0x00 01: LGT92 Version 232 232 * 0x00 02: LBT1 233 233 * 0x00 03: LSE01/LDDS75/LDDS20/LSPH01/LLMS01/LSNPK01 234 234 256 +((( 235 235 **yy: Frequency Band:** 258 +))) 236 236 237 237 * 0x01: EU868 238 238 * 0x02: US915 ... ... @@ -245,7 +245,9 @@ 245 245 * 0x09: AS923-2 246 246 * 0xa0: AS923-3 247 247 271 +((( 248 248 **zz: Subband** 273 +))) 249 249 250 250 firmware version: v1.1.0 ~-~-> 110 251 251 ... ... @@ -275,6 +275,8 @@ 275 275 OK 276 276 ))) 277 277 303 + 304 + 278 278 = 5. Keys, IDs and EUIs management = 279 279 280 280 == 5.1 Application EUI == ... ... @@ -293,6 +293,8 @@ 293 293 ))) 294 294 |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK 295 295 323 + 324 + 296 296 == 5.2 Application Key == 297 297 298 298 Feature: Get or Set the Application Key. ... ... @@ -309,6 +309,8 @@ 309 309 ))) 310 310 |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK 311 311 341 + 342 + 312 312 == 5.3 Application Session Key == 313 313 314 314 Feature: Get or Set the Application Session Key. ... ... @@ -973,7 +973,7 @@ 973 973 **AT+RX1TWO** is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 974 974 ))) 975 975 976 -[[image:image-2022051 1120050-1.png]]1007 +[[image:image-20220526162535-1.png]] 977 977 978 978 ((( 979 979 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. ... ... @@ -1078,6 +1078,6 @@ 1078 1078 1079 1079 Same as: 1080 1080 1081 -* AT+ADR=0 [[Reference>>h ttp://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#Adaptive_Data_Rate]]1082 -* AT+DR=5 [[Reference>> url:https://wiki.dragino.com/index.php/End_Device_Downlink_Command#Data_Rate]]1083 -* AT+TXP=0 [[Reference>> url:https://wiki.dragino.com/index.php/End_Device_Downlink_Command#Transmit_Power]]1112 +* AT+ADR=0 [[Reference>>||anchor="H7.1AdaptiveDataRate"]] 1113 +* AT+DR=5 [[Reference>>||anchor="H7.4DataRate"]] 1114 +* AT+TXP=0 [[Reference>>||anchor="H7.14TransmitPower"]]
- image-20220526162535-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +149.4 KB - Content