Changes for page End Device AT Commands and Downlink Command
Last modified by kai on 2024/09/06 10:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -123,7 +123,9 @@ 123 123 **Downlink Command: 0x01** 124 124 {{/info}} 125 125 126 +((( 126 126 Format: Command Code (0x01) followed by 3 bytes time value. 128 +))) 127 127 128 128 ((( 129 129 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. ... ... @@ -969,11 +969,15 @@ 969 969 ))) 970 970 |(% style="width:163px" %)AT+RX1WTO=60|(% style="width:201px" %)Set RXwindows1 timeout|(% style="width:93px" %)OK 971 971 972 -AT+RX1TWO is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 974 +((( 975 +**AT+RX1TWO** is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 976 +))) 973 973 974 974 [[image:image-20220511120050-1.png]] 975 975 980 +((( 976 976 Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink. 982 +))) 977 977 978 978 == 7.21 Get or Set RXwindows2 timeout == 979 979