<
From version < 15.1 >
edited by Xiaoling
on 2022/05/11 12:01
To version < 60.5 >
edited by Xiaoling
on 2023/03/27 14:01
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,54 +1,119 @@
1 -Contens
1 + **Table of** **Contents:**
2 2  
3 3  {{toc/}}
4 4  
5 5  
6 +
6 6  = 1. Introduction =
7 7  
9 +
8 8  Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
9 9  
10 -* **Common Commands:** They should be available for each sensor, such as: change uplink interval, reset device.
11 -* **Sensor Related Commands:** Only for special sensor, such as control relay, poll RS485 device.
12 +* (% style="color:blue" %)**Common Commands:** (%%) They should be available for each sensor, such as: change uplink interval, reset device.
13 +* (% style="color:blue" %)**Sensor Related Commands:** (%%) Only for special sensor, such as control relay, poll RS485 device.
12 12  
15 +(((
13 13  **This page shows the common commands since Dragino LoRaWAN stack DR-LWS-005. Make sure the end node support stack higher than DR-LWS-005 before checking this page.**
14 -
17 +)))
15 15  
19 +
16 16  = 2. How to use AT Commands or Downlink command =
17 17  
18 -* For AT Command , See Devices User Manual for Device. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
19 -* For LoRaWAN Downlink: The gateway transfer downlink command in HEX format. This page shows the HEX format downlink code for each command. but some servers use base64 as downlink code. Below are reference for how to use downlink command:
20 -** Use HEX format to send a downlink: [[TTN v3>>url:https://wiki.dragino.com/index.php/Notes_for_TTN#Send_Downlink_message]]
21 -** Use Base64 format to send a downlink: [[Chirpstack>>url:https://wiki.dragino.com/index.php/Notes_for_ChirpStack#Downlink]].
22 -** See use note for more serves [[Servers Note>>url:https://wiki.dragino.com/index.php/Main_Page#Use_Note_for_Server]]
23 23  
23 +* **AT Command** : See Devices User Manual for how to connect to device via USB TTL adapter and use. The user manual can be found in each product page of [[Dragino Official Website>>url:http://www.dragino.com/]]
24 +* **LoRaWAN Downlink Command**: The gateway transfer downlink command in HEX format. This page shows the Downlink Command In HEX format. Please note some LoRaWAN servers use base64 as downlink code so user need to convert HEX to Base64 and use. Below are references for how to use downlink command:
25 +** Use HEX format to send a downlink: [[TTN v3>>Notes for TTN]]
26 +** Use Base64 format to send a downlink: [[Chirpstack>>Notes for ChirpStack]], [[How to Convert>>http://wiki.dragino.com/xwiki/bin/view/Main/Notes%20for%20ChirpStack/#H4.1ConvertHEXtoBase64]]?
27 +** See use note for more serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)
28 +
29 +(% style="display:none" %) (%%)
30 +
24 24  = 3. Support End Node and firmware version =
25 25  
26 -(% border="1" style="background-color:#ffffcc; border:1; color:green; width:995.222px" %)
27 -|=(% colspan="3" style="width: 992px;" %)Dragino STM32 base hardware Firmware / LoRaWAN stack list
28 -|(% style="width:187px" %)**Model**|(% style="width:349px" %)**Description**|(% style="width:453px" %)**Firmware Version <~-~-> Stack Version**
29 -|(% style="width:187px" %)[[LSN50-v1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/128-lsn50.html]], [[LSN50-V2>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/155-lsn50-v2.html]],|(% style="width:349px" %)Open Source Generic LoRaWAN Sensor Node|(% style="width:453px" %)LSN50 v1.6.0 <~-~-> DR-LWS-003;(((
33 +
34 +(% border="1" style="background-color:#ffffcc; color:green; width:966px" %)
35 +|=(% colspan="3" style="width: 963px;" %)(((
36 +Dragino STM32 base hardware Firmware / LoRaWAN stack list
37 +)))
38 +|(% style="width:187px" %)(((
39 +**Model**
40 +)))|(% style="width:330px" %)(((
41 +**Description**
42 +)))|(% style="width:445px" %)(((
43 +**Firmware Version <~-~-> Stack Version**
44 +)))
45 +|(% style="width:187px" %)(((
46 +[[LSN50-v1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/128-lsn50.html]], [[LSN50-V2>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/155-lsn50-v2.html]],
47 +)))|(% style="width:330px" %)(((
48 +Open Source Generic LoRaWAN Sensor Node
49 +)))|(% style="width:445px" %)(((
50 +(((
51 +LSN50 v1.6.0 <~-~-> DR-LWS-003;
52 +)))
53 +
54 +(((
55 +(((
30 30  LSN50 v1.7.0 <~-~-> DR-LWS-005; ~-~-> Support since this version
31 31  )))
32 -|(% style="width:187px" %)[[LGT92>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/142-lgt-92.html]],|(% style="width:349px" %)LoRaWAN GPS Tracker|(% style="width:453px" %)LGT92 v1.6.3 <~-~-> DR-LWS-003;(((
58 +)))
59 +)))
60 +|(% style="width:187px" %)(((
61 +[[LGT92>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/142-lgt-92.html]],
62 +)))|(% style="width:330px" %)(((
63 +LoRaWAN GPS Tracker
64 +)))|(% style="width:445px" %)(((
65 +(((
66 +LGT92 v1.6.3 <~-~-> DR-LWS-003;
67 +)))
68 +
69 +(((
70 +(((
33 33  LGT92 v1.6.4 <~-~-> DR-LWS-005;~-~-> Support since this version
34 34  )))
35 -|(% style="width:187px" %)[[LBT1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/165-lbt1.html]],|(% style="width:349px" %)LoRaWAN BLE Indoor Tracker|(% style="width:453px" %)LBT1 v1.0 <~-~-> DR-LWS-005;
36 -|(% style="width:187px" %)[[RS485-LN>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/154-rs485-ln.html]],|(% style="width:349px" %)LoRaWAN RS485 Modbus Converter|(% style="width:453px" %)RS485-LN v1.3 <~-~-> DR-LWS-005;
37 -|(% style="width:187px" %)[[LHT65>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/151-lht65.html]],|(% style="width:349px" %)LoRaWAN Temperature & Humidity Sensor|(% style="width:453px" %)LHT65 v1.7 <~-~-> DR-LWS-003;(((
73 +)))
74 +)))
75 +|(% style="width:187px" %)(((
76 +[[LBT1>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/165-lbt1.html]],
77 +)))|(% style="width:330px" %)(((
78 +LoRaWAN BLE Indoor Tracker
79 +)))|(% style="width:445px" %)(((
80 +LBT1 v1.0 <~-~-> DR-LWS-005;
81 +)))
82 +|(% style="width:187px" %)(((
83 +[[RS485-LN>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/154-rs485-ln.html]],
84 +)))|(% style="width:330px" %)(((
85 +LoRaWAN RS485 Modbus Converter
86 +)))|(% style="width:445px" %)(((
87 +RS485-LN v1.3 <~-~-> DR-LWS-005;
88 +)))
89 +|(% style="width:187px" %)(((
90 +[[LHT65>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/151-lht65.html]],
91 +)))|(% style="width:330px" %)(((
92 +LoRaWAN Temperature & Humidity Sensor
93 +)))|(% style="width:445px" %)(((
94 +(((
95 +LHT65 v1.7 <~-~-> DR-LWS-003;
96 +)))
97 +
98 +(((
99 +(((
38 38  LHT65 v1.8.0 <~-~-> DR-LWS-005;~-~-> Support since this version
39 39  )))
102 +)))
103 +)))
40 40  
105 +(% style="display:none" %) (%%)
106 +
41 41  = 4. System Management Commands =
42 42  
43 43  == 4.1 Change Uplink Interval ==
44 44  
111 +
45 45  Feature: Change LoRaWAN End Node Transmit Interval.
46 46  
47 -(% class="box infomessage" %)
48 -(((
49 -**AT Command: AT+TDC**
50 -)))
51 51  
115 +(% style="color:blue" %)**AT Command: AT+TDC**
116 +
52 52  (% border="1" style="background-color:#ffffcc; color:green; width:727.222px" %)
53 53  |=(% colspan="3" style="width: 724px;" %)AT+TDC
54 54  |(% style="width:165px" %)**Command Example**|(% style="width:227px" %)**Function**|(% style="width:329px" %)**Response**
... ... @@ -61,29 +61,35 @@
61 61  Set transmit interval to 60000ms = 60 seconds
62 62  )))
63 63  
64 -{{info}}
65 -**Downlink Command: 0x01**
66 -{{/info}}
129 +(((
130 +
67 67  
132 +(% style="color:blue" %)**Downlink Command: 0x01**
133 +
68 68  Format: Command Code (0x01) followed by 3 bytes time value.
135 +)))
69 69  
70 -If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
137 +(((
138 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
139 +)))
71 71  
72 -* **Example 1**: Downlink Payload:** 0100001E** ~/~/ Set Transmit Interval (TDC) = 30 seconds
73 -* **Example 2**: Downlink Payload:** 0100003C** ~/~/ Set Transmit Interval (TDC) = 60 seconds
141 +* **Example 1**: Downlink Payload:** 0100001E**  ~/~/ Set Transmit Interval (TDC) = 30 seconds
142 +* **Example 2**: Downlink Payload:** 0100003C**  ~/~/ Set Transmit Interval (TDC) = 60 seconds
74 74  
144 +(% style="display:none" %) (%%)
145 +
75 75  == 4.2 Reboot End Node ==
76 76  
148 +
77 77  Feature: Reboot End Node to perform a new OTAA or ABP Join.
78 78  
79 -{{info}}
80 -**AT Command: ATZ**
81 -{{/info}}
82 82  
83 -(% border="1" style="background-color:#ffffcc; color:green; width:727.222px" %)
84 -|=(% colspan="3" %)ATZ: Trig a reset of the MCU
85 -|**Command Example**|**Function**|**Response**
86 -|ATZ|Reset MCU|(((
152 +(% style="color:blue" %)**AT Command: ATZ**
153 +
154 +(% border="1" style="background-color:#ffffcc; color:green; width:546px" %)
155 +|=(% colspan="3" style="width: 543px;" %)ATZ: Trig a reset of the MCU
156 +|(% style="width:157px" %)**Command Example**|(% style="width:92px" %)**Function**|(% style="width:294px" %)**Response**
157 +|(% style="width:157px" %)ATZ|(% style="width:92px" %)Reset MCU|(% style="width:294px" %)(((
87 87  Device reset and show booting info
88 88  
89 89  LSN50 Device/LoRa ST Module
... ... @@ -97,26 +97,29 @@
97 97  <followed by the Tx and Rx information>
98 98  )))
99 99  
100 -{{info}}
101 -**Downlink Command: 0x04**
102 -{{/info}}
171 +(% style="color:blue" %)**Downlink Command: 0x04**
103 103  
173 +(((
104 104  Format: Command Code (0x04) followed by FF.
175 +)))
105 105  
106 -If the downlink payload=**04FF**, the end node will reboot.
177 +(((
178 +If the downlink payload=**04FF**, the end node will reboot.
179 +)))
107 107  
181 +
108 108  == 4.3 Reset to factory Default ==
109 109  
184 +
110 110  Feature: Reset the parameters to Factory Default, factory default value depends on the firmware settings, the OTAA and ABP keys will reserve after this command.
111 111  
112 -{{info}}
113 -**AT Command: AT+FDR**
114 -{{/info}}
115 115  
116 -(% border="1" style="background-color:#ffffcc; color:green; width:831.222px" %)
117 -|=(% colspan="3" style="width: 828px;" %)Reset to factory default
118 -|(% style="width:181px" %)**Command Example**|(% style="width:181px" %)**Function**|(% style="width:465px" %)**Response**
119 -|(% style="width:181px" %)AT+FDR|(% style="width:181px" %)Reset to factory default|(% style="width:465px" %)(((
188 +(% style="color:blue" %)**AT Command: AT+FDR**
189 +
190 +(% border="1" style="background-color:#ffffcc; color:green; width:789px" %)
191 +|=(% colspan="3" style="width: 786px;" %)Reset to factory default
192 +|(% style="width:154px" %)**Command Example**|(% style="width:175px" %)**Function**|(% style="width:456px" %)**Response**
193 +|(% style="width:154px" %)AT+FDR|(% style="width:175px" %)Reset to factory default|(% style="width:456px" %)(((
120 120  Device reset to factory default parameters and show booting info
121 121  
122 122  LSN50 Device/LoRa ST Module
... ... @@ -130,47 +130,59 @@
130 130  Please set the parameters or reset Device to apply change
131 131  )))
132 132  
133 -{{info}}
134 -**Downlink Command: 0x04**
135 -{{/info}}
207 +(% style="color:blue" %)**Downlink Command: 0x04**
136 136  
209 +(((
137 137  Format: Command Code (0x04) followed by FE.
211 +)))
138 138  
213 +(((
139 139  If the downlink payload=**04FE**, Reset Parameters to Factory Default, Keys Reserve.
215 +)))
140 140  
141 141  
142 142  == 4.4 Show Firmware Version ==
143 143  
220 +
144 144  Feature: Show firmware version. No downlink command yet.
145 145  
146 -{{info}}
147 -**AT Command: AT+VER**
148 -{{/info}}
149 149  
150 -(% border="1" style="background-color:#ffffcc; color:green" %)
151 -|=(% colspan="3" %)AT+VER: Image Version and Frequency Band
152 -|**Command Example**|**Function**|**Response**
153 -|AT+VER=?|Show Image version and Frequency Band|(((
224 +(% style="color:blue" %)**AT Command: AT+VER**
225 +
226 +(% border="1" style="background-color:#ffffcc; color:green; width:542px" %)
227 +|=(% colspan="3" style="width: 539px;" %)AT+VER: Image Version and Frequency Band
228 +|(% style="width:157px" %)**Command Example**|(% style="width:295px" %)**Function**|(% style="width:86px" %)**Response**
229 +|(% style="width:157px" %)AT+VER=?|(% style="width:295px" %)Show Image version and Frequency Band|(% style="width:86px" %)(((
154 154  1.3 EU868
155 155  
156 156  OK
157 157  )))
158 158  
159 -{{info}}
160 -**Downlink Command: 0x26 (Valid in 006 stack)**
161 -{{/info}}
235 +(% style="color:blue" %)**Downlink Command: 0x26 (Valid in 006 stack)**
162 162  
237 +(((
163 163  Downlink Format: 0x26
239 +)))
164 164  
241 +(((
165 165  Device will reply with firmware version info, device info. frequency band info. detail please check device user manual. Total 5 bytes Example: If device is of firmware version 1.1.0 Upload: xx ~-~- yy ~-~- zz ~-~- 110 total 5 bytes
243 +)))
166 166  
245 +(((
246 +
247 +
167 167  **xx: Software Type:**
249 +)))
168 168  
169 169  * 0x00 01: LGT92 Version
170 170  * 0x00 02: LBT1
171 171  * 0x00 03: LSE01/LDDS75/LDDS20/LSPH01/LLMS01/LSNPK01
172 172  
255 +(((
256 +
257 +
173 173  **yy: Frequency Band:**
259 +)))
174 174  
175 175  * 0x01: EU868
176 176  * 0x02: US915
... ... @@ -183,7 +183,11 @@
183 183  * 0x09: AS923-2
184 184  * 0xa0: AS923-3
185 185  
272 +(((
273 +
274 +
186 186  **zz: Subband**
276 +)))
187 187  
188 188  firmware version: v1.1.0 ~-~-> 110
189 189  
... ... @@ -190,12 +190,12 @@
190 190  
191 191  == 4.5 Show System Configure ==
192 192  
283 +
193 193  Feature: Show All configure. No downlink command yet.
194 194  
195 -{{info}}
196 -**AT Command: AT+CFG**
197 -{{/info}}
198 198  
287 +(% style="color:blue" %)**AT Command: AT+CFG**
288 +
199 199  (% border="1" style="background-color:#ffffcc; color:green; width:599.222px" %)
200 200  |=(% colspan="3" style="width: 596px;" %)AT+CFG: Print all configurations
201 201  |(% style="width:160px" %)**Command Example**|(% style="width:154px" %)**Function**|(% style="width:280px" %)**Response**
... ... @@ -217,12 +217,12 @@
217 217  
218 218  == 5.1 Application EUI ==
219 219  
310 +
220 220  Feature: Get or Set the Application EUI.
221 221  
222 -{{info}}
223 -**AT Command: AT+APPEUI**
224 -{{/info}}
225 225  
314 +(% style="color:blue" %)**AT Command: AT+APPEUI**
315 +
226 226  (% border="1" style="background-color:#ffffcc; color:green; width:686.222px" %)
227 227  |=(% colspan="3" style="width: 683px;" %)AT+APPEUI
228 228  |(% style="width:305px" %)**Command Example**|(% style="width:186px" %)**Function**|(% style="width:191px" %)**Response**
... ... @@ -231,14 +231,16 @@
231 231  )))
232 232  |(% style="width:305px" %)AT+APPEUI=00 b3 d5 7e f0 00 4d 34|(% style="width:186px" %)Set the Application EUI|(% style="width:191px" %)OK
233 233  
324 +(% style="display:none" %) (%%)
325 +
234 234  == 5.2 Application Key ==
235 235  
328 +
236 236  Feature: Get or Set the Application Key.
237 237  
238 -{{info}}
239 -**AT Command: AT+APPKEY**
240 -{{/info}}
241 241  
332 +(% style="color:blue" %)**AT Command: AT+APPKEY**
333 +
242 242  (% border="1" style="background-color:#ffffcc; color:green; width:976.222px" %)
243 243  |=(% colspan="3" style="width: 973px;" %)AT+APPKEY
244 244  |(% style="width:441px" %)**Command Example**|(% style="width:180px" %)**Function**|(% style="width:350px" %)**Response**
... ... @@ -247,14 +247,16 @@
247 247  )))
248 248  |(% style="width:441px" %)AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35|(% style="width:180px" %)Set the Application Key|(% style="width:350px" %)OK
249 249  
342 +(% style="display:none" %) (%%)
343 +
250 250  == 5.3 Application Session Key ==
251 251  
346 +
252 252  Feature: Get or Set the Application Session Key.
253 253  
254 -{{info}}
255 -**AT Command: AT+APPSKEY**
256 -{{/info}}
257 257  
350 +(% style="color:blue" %)**AT Command: AT+APPSKEY**
351 +
258 258  (% border="1" style="background-color:#ffffcc; color:green; width:1040.22px" %)
259 259  |=(% colspan="3" style="width: 1037px;" %)AT+APPSKEY
260 260  |(% style="width:451px" %)**Command Example**|(% style="width:231px" %)**Function**|(% style="width:354px" %)**Response**
... ... @@ -265,14 +265,16 @@
265 265  OK
266 266  )))
267 267  
362 +(% style="display:none" %) (%%)
363 +
268 268  == 5.4 Device Address ==
269 269  
366 +
270 270  Feature: Get or Set the Device Address.
271 271  
272 -{{info}}
273 -**AT Command: AT+DADDR**
274 -{{/info}}
275 275  
370 +(% style="color:blue" %)**AT Command: AT+DADDR**
371 +
276 276  (% border="1" style="background-color:#ffffcc; color:green; width:795.222px" %)
277 277  |=(% colspan="3" style="width: 792px;" %)AT+DADDR
278 278  |(% style="width:192px" %)**Command Example**|(% style="width:241px" %)**Function**|(% style="width:359px" %)**Response**
... ... @@ -283,14 +283,16 @@
283 283  )))
284 284  |(% style="width:192px" %)AT+DADDR=A8 40 41 FF|(% style="width:241px" %)Set the Application Session Key.|(% style="width:359px" %)OK
285 285  
382 +(% style="display:none" %) (%%)
383 +
286 286  == 5.5 Device EUI ==
287 287  
386 +
288 288  Feature: Get or Set the Device EUI.
289 289  
290 -{{info}}
291 -**AT Command: AT+DEUI**
292 -{{/info}}
293 293  
390 +(% style="color:blue" %)**AT Command: AT+DEUI**
391 +
294 294  (% border="1" style="background-color:#ffffcc; color:green; width:1035.22px" %)
295 295  |=(% colspan="3" style="width: 1032px;" %)AT+DEUI
296 296  |(% style="width:250px" %)**Command Example**|(% style="width:147px" %)**Function**|(% style="width:634px" %)**Response**
... ... @@ -301,14 +301,16 @@
301 301  OK
302 302  )))
303 303  
402 +(% style="display:none" %) (%%)
403 +
304 304  == 5.6 Network ID ==
305 305  
406 +
306 306  Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection)
307 307  
308 -{{info}}
309 -**AT Command: AT+NWKID**
310 -{{/info}}
311 311  
410 +(% style="color:blue" %)**AT Command: AT+NWKID**
411 +
312 312  (% border="1" style="background-color:#ffffcc; color:green; width:448.222px" %)
313 313  |=(% colspan="3" style="width: 445px;" %)AT+NWKID
314 314  |(% style="width:191px" %)**Command Example**|(% style="width:153px" %)**Function**|(% style="width:101px" %)**Response**
... ... @@ -317,14 +317,16 @@
317 317  )))
318 318  |(% style="width:191px" %)AT+NWKID=A8 40 41 FF|(% style="width:153px" %)Set the Network ID.|(% style="width:101px" %)OK
319 319  
420 +(% style="display:none" %) (%%)
421 +
320 320  == 5.7 Network Session Key ==
321 321  
424 +
322 322  Feature: Get or Set the Network Session Key
323 323  
324 -{{info}}
325 -**AT Command: AT+NWKSKEY**
326 -{{/info}}
327 327  
428 +(% style="color:blue" %)**AT Command: AT+NWKSKEY**
429 +
328 328  (% border="1" style="background-color:#ffffcc; color:green; width:1017.22px" %)
329 329  |=(% colspan="3" style="width: 1014px;" %)AT+NWKSKEY
330 330  |(% style="width:455px" %)**Command Example**|(% style="width:215px" %)**Function**|(% style="width:343px" %)**Response**
... ... @@ -333,16 +333,20 @@
333 333  )))
334 334  |(% style="width:455px" %)AT+NWKSKEY=A8 40 41 FF FF 12 34 56 00 01 02 04 05 06 06 07|(% style="width:215px" %)Set the Network Session Key.|(% style="width:343px" %)OK
335 335  
438 +(% style="display:none" %) (%%)
439 +
336 336  = 6. Joining and sending date on LoRaWAN network =
337 337  
338 338  == 6.1 Confirm Mode ==
339 339  
444 +=== 6.1.1  AT+CFM command before DR-LWS007 software stack ===
445 +
446 +
340 340  Feature: Get or Set the confirmation mode (0-1).
341 341  
342 -{{info}}
343 -**AT Command: AT+CFM**
344 -{{/info}}
345 345  
450 +(% style="color:blue" %)**AT Command: AT+CFM**
451 +
346 346  (% border="1" style="background-color:#ffffcc; color:green; width:710.222px" %)
347 347  |=(% colspan="3" style="width: 707px;" %)AT+CFM
348 348  |(% style="width:155px" %)**Command Example**|(% style="width:205px" %)**Function**|(% style="width:346px" %)**Response**
... ... @@ -352,38 +352,87 @@
352 352  |(% style="width:155px" %)AT+CFM=1|(% style="width:205px" %)Set the confirmation mode|(% style="width:346px" %)OK
353 353  |(% style="width:155px" %)AT+CFM=2|(% style="width:205px" %)Set the confirmation mode|(% style="width:346px" %)While Error in format, return AT_PARAM_ERROR
354 354  
355 -Downlink Command: 0x05
461 +(% style="color:blue" %)**Downlink Command: 0x05**
356 356  
357 357  Format: Command Code (0x05) followed by 2 bytes mode value.
358 358  
359 359  If the downlink payload=0501, it means set end node to use confirm mode, while type code is 05.
360 360  
361 -* Example 1: Downlink Payload: 0501 ~/~/ Set AT+CFM=1
362 -* Example 2: Downlink Payload: 0500 ~/~/ Set AT+CFM=0
467 +* **Example 1:** Downlink Payload: 0501  ~/~/ Set AT+CFM=1
468 +* **Example 2:** Downlink Payload: 0500  ~/~/ Set AT+CFM=0
363 363  
470 +(% style="display:none" %) (%%)
471 +
472 +=== 6.1.2  AT+CFM command since DR-LWS007 software stack ===
473 +
474 +
475 +(% style="color:blue" %)**AT Command: AT+CFM**
476 +
477 +(% border="1" style="background-color:#ffffcc; color:green; width:710.222px" %)
478 +|=(% colspan="3" style="width: 707px;" %)AT+CFM
479 +|(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response**
480 +|(% style="width:160px" %)(((
481 +AT+CFM=1,0,0
482 +
483 +value1
484 +)))|(% style="width:198px" %)confirmed uplink|(% style="width:349px" %)(((
485 +1
486 +
487 +OK
488 +)))
489 +|(% style="width:160px" %)(((
490 +AT+CFM=0,?,0
491 +
492 +value2
493 +)))|(% style="width:198px" %)set max retry , range: 0 ~~ 7|(% style="width:349px" %)(((
494 +0~~7
495 +
496 +OK
497 +)))
498 +|(% style="width:160px" %)(((
499 +AT+CFM=0,0,1
500 +
501 +value3
502 +)))|(% style="width:198px" %)uplink fcnt increase by 1 for each retry|(% style="width:349px" %)(((
503 +1
504 +
505 +OK
506 +)))
507 +
508 +(% style="color:blue" %)**Downlink Command: 0x05**
509 +
510 +Format: Command Code (0x05) followed by 2 bytes mode value.
511 +
512 +If the downlink payload=05010101, it means set end node to use confirm mode, while type code is 05.
513 +
514 +* **Example 1:** Downlink Payload: 05010101  ~/~/ Set AT+CFM=1,1,1
515 +* **Example 2:** Downlink Payload: 05000700  ~/~/ Set AT+CFM=0,7,0
516 +
517 +(% style="display:none" %) (%%)
518 +
364 364  == 6.2 Confirm Status ==
365 365  
521 +
366 366  Feature: Get confirmation status of the last AT+SEND (0-1).
367 367  
368 -{{info}}
369 -**AT Command: AT+CFS**
370 -{{/info}}
371 371  
372 -(% border="1" style="background-color:#ffffcc; color:green; width:534.222px" %)
373 -|=(% colspan="3" style="width: 531px;" %)AT+CFS
374 -|(% style="width:156px" %)**Command Example**|(% style="width:193px" %)**Function**|(% style="width:178px" %)**Response**
375 -|(% style="width:156px" %)AT+CFS=?|(% style="width:193px" %)Get confirmation status|(% style="width:178px" %)0(((
525 +(% style="color:blue" %)**AT Command: AT+CFS**
526 +
527 +(% border="1" style="background-color:#ffffcc; color:green; width:463px" %)
528 +|=(% colspan="3" style="width: 460px;" %)AT+CFS
529 +|(% style="width:156px" %)**Command Example**|(% style="width:193px" %)**Function**|(% style="width:107px" %)**Response**
530 +|(% style="width:156px" %)AT+CFS=?|(% style="width:193px" %)Get confirmation status|(% style="width:107px" %)0(((
376 376  OK
377 377  )))
378 378  
379 379  == 6.3 Join LoRa® Network ==
380 380  
536 +
381 381  Feature: Join network.
382 382  
383 -{{info}}
384 -**AT Command: AT+JOIN**
385 -{{/info}}
386 386  
540 +(% style="color:blue" %)**AT Command: AT+JOIN**
541 +
387 387  (% border="1" style="background-color:#ffffcc; color:green; width:647.222px" %)
388 388  |=(% colspan="3" style="width: 644px;" %)AT+JOIN
389 389  |(% style="width:163px" %)**Command Example**|(% style="width:147px" %)**Function**|(% style="width:334px" %)**Response**
... ... @@ -395,12 +395,12 @@
395 395  
396 396  == 6.4 LoRa® Network Join Mode ==
397 397  
553 +
398 398  Feature: Get or Set the Network Join Mode. (0: ABP, 1: OTAA).
399 399  
400 -{{info}}
401 -**AT Command: AT+NJM**
402 -{{/info}}
403 403  
557 +(% style="color:blue" %)**AT Command: AT+NJM**
558 +
404 404  (% border="1" style="background-color:#ffffcc; color:green; width:753.222px" %)
405 405  |=(% colspan="3" style="width: 750px;" %)AT+NJM
406 406  |(% style="width:162px" %)**Command Example**|(% style="width:227px" %)**Function**|(% style="width:361px" %)**Response**
... ... @@ -410,25 +410,25 @@
410 410  |(% style="width:162px" %)AT+NJM=0|(% style="width:227px" %)Set the Network Join Mode|(% style="width:361px" %)OK
411 411  |(% style="width:162px" %)AT+NJM=2|(% style="width:227px" %)Set the Network Join Mode|(% style="width:361px" %)While Error in format, return AT_PARAM_ERROR
412 412  
413 -{{info}}
414 -**Downlink Command: 0x20**
415 -{{/info}}
568 +(% style="color:blue" %)**Downlink Command: 0x20**
416 416  
417 417  Format: Command Code (0x20) followed by 1 bytes mode value.
418 418  
419 419  If the downlink payload=2000, it means set the Network Join Mode, while type code is 20.
420 420  
421 -* **Example 1: **Downlink Payload: **2000** ~/~/ Set AT+NJM=O
422 -* **Example 2:** Downlink Payload: **2001** ~/~/ Set AT+NJM=1
574 +* **Example 1: **Downlink Payload: **2000                  ** ~/~/ Set AT+NJM=0
575 +* **Example 2:** Downlink Payload: **2001**  ~/~/ Set AT+NJM=1
423 423  
577 +(% style="display:none" %) (%%)
578 +
424 424  == 6.5 LoRa® Network Join Status ==
425 425  
581 +
426 426  Feature: LoRa® Network Join Status.
427 427  
428 -{{info}}
429 -**AT Command: AT+NJS**
430 -{{/info}}
431 431  
585 +(% style="color:blue" %)**AT Command: AT+NJS**
586 +
432 432  (% border="1" style="background-color:#ffffcc; color:green; width:498.222px" %)
433 433  |=(% colspan="3" style="width: 495px;" %)AT+NJS
434 434  |(% style="width:169px" %)**Command Example**|(% style="width:164px" %)**Function**|(% style="width:161px" %)**Response**
... ... @@ -436,14 +436,16 @@
436 436  OK
437 437  )))
438 438  
594 +(% style="display:none" %) (%%)
595 +
439 439  == 6.6 Print Last Received Data in Raw Format ==
440 440  
598 +
441 441  Feature: Print Last Received Data in Raw Format<port:data>.
442 442  
443 -{{info}}
444 -**AT Command: AT+RECV**
445 -{{/info}}
446 446  
602 +(% style="color:blue" %)**AT Command: AT+RECV**
603 +
447 447  (% border="1" style="background-color:#ffffcc; color:green; width:587.222px" %)
448 448  |=(% colspan="3" style="width: 584px;" %)AT+RECV
449 449  |(% style="width:161px" %)**Command Example**|(% style="width:272px" %)**Function**|(% style="width:150px" %)**Response**
... ... @@ -451,14 +451,16 @@
451 451  OK
452 452  )))
453 453  
611 +(% style="display:none" %) (%%)
612 +
454 454  == 6.7 Print Last Received Data in Binary Format ==
455 455  
615 +
456 456  Feature: Print Last Received Data in Binary Format<port:data>.
457 457  
458 -{{info}}
459 -**AT Command: AT+RECVB**
460 -{{/info}}
461 461  
619 +(% style="color:blue" %)**AT Command: AT+RECVB**
620 +
462 462  (% border="1" style="background-color:#ffffcc; color:green; width:793.222px" %)
463 463  |=(% colspan="3" style="width: 790px;" %)AT+RECVB
464 464  |(% style="width:173px" %)**Command Example**|(% style="width:497px" %)**Function**|(% style="width:120px" %)**Response**
... ... @@ -466,53 +466,54 @@
466 466  OK
467 467  )))
468 468  
628 +(% style="display:none" %) (%%)
629 +
469 469  == 6.8 Send Text Data ==
470 470  
632 +
471 471  Feature: Send Text Data<port:data>.
472 472  
473 -{{info}}
474 -**AT Command: AT+SEND**
475 -{{/info}}
476 476  
636 +(% style="color:blue" %)**AT Command: AT+SEND**
637 +
477 477  (% border="1" style="background-color:#ffffcc; color:green; width:991.222px" %)
478 478  |=(% colspan="3" style="width: 988px;" %)AT+SEND
479 479  |(% style="width:201px" %)**Command Example**|(% style="width:340px" %)**Function**|(% style="width:446px" %)**Response**
480 480  |(% style="width:201px" %)AT+SEND=12:hello world|(% style="width:340px" %)Send text data along with the application port.|(% style="width:446px" %)OK(((
481 481  While Error in format, return
482 -
483 483  AT_BUSY_ERROR/AT_BUSY_ERROR/AT_NO_NETWORK_JOINED
484 -
485 -
486 486  )))
487 487  
646 +(% style="display:none" %) (%%)
647 +
488 488  == 6.9 Send Hexadecimal Data ==
489 489  
650 +
490 490  Feature: Send hexadecimal data along with the application port.
491 491  
492 -{{info}}
493 -**AT Command: AT+SENDB**
494 -{{/info}}
495 495  
496 -(% border="1" style="background-color:#ffffcc; color:green; width:1120.22px" %)
497 -|=(% colspan="3" style="width: 1117px;" %)AT+SENDB
498 -|(% style="width:257px" %)**Command Example**|(% style="width:406px" %)**Function**|(% style="width:453px" %)**Response**
499 -|(% style="width:257px" %)AT+SENDB=12:abcdef0123456789|(% style="width:406px" %)Send hexadecimal data along with the application port.|(% style="width:453px" %)OK
500 -|(% style="width:257px" %)AT+SENDB=abcdef0123456789|(% style="width:406px" %)Send hexadecimal data along with the application port.|(% style="width:453px" %)While Error in format, return(((
501 -AT_PARAM_ERROR AT_BUSY_ERROR/AT_NO_NETWORK_JOINED
654 +(% style="color:blue" %)**AT Command: AT+SENDB**
502 502  
503 -
656 +(% border="1" style="background-color:#ffffcc; color:green; width:1101px" %)
657 +|=(% colspan="3" style="width: 1098px;" %)AT+SENDB
658 +|(% style="width:257px" %)**Command Example**|(% style="width:394px" %)**Function**|(% style="width:446px" %)**Response**
659 +|(% style="width:257px" %)AT+SENDB=12:abcdef0123456789|(% style="width:394px" %)Send hexadecimal data along with the application port.|(% style="width:446px" %)OK
660 +|(% style="width:257px" %)AT+SENDB=abcdef0123456789|(% style="width:394px" %)Send hexadecimal data along with the application port.|(% style="width:446px" %)While Error in format, return(((
661 +AT_PARAM_ERROR AT_BUSY_ERROR/AT_NO_NETWORK_JOINED
504 504  )))
505 505  
664 +(% style="display:none" %) (%%)
665 +
506 506  = 7. LoRaWAN network management =
507 507  
508 508  == 7.1 Adaptive Data Rate ==
509 509  
670 +
510 510  Feature: Get or Set the Adaptive Data Rate setting. (0: off, 1: on).
511 511  
512 -{{info}}
513 -**AT Command: AT+ADR**
514 -{{/info}}
515 515  
674 +(% style="color:blue" %)**AT Command: AT+ADR**
675 +
516 516  (% border="1" style="background-color:#ffffcc; color:green; width:683.222px" %)
517 517  |=(% colspan="3" style="width: 680px;" %)AT+ADR
518 518  |(% style="width:162px" %)**Command Example**|(% style="width:266px" %)**Function**|(% style="width:250px" %)**Response**
... ... @@ -524,24 +524,23 @@
524 524  AT_PARAM_ERROR
525 525  )))
526 526  
527 -{{info}}
528 -**Downlink Command: 0x22**
529 -{{/info}}
687 +(% style="color:blue" %)**Downlink Command: 0x22**
530 530  
531 -
532 532  If the downlink payload=2201, it means setting the adaptive data rate to 1, while type code is 22.
533 533  
534 -* **Example 1**: Downlink Payload: **2201** ~/~/ Set AT+ADR=1.
535 -* **Example 2**: Downlink Payload: **2200FFFF** ~/~/ Set AT+ADR=0.
691 +* **Example 1**: Downlink Payload: **2201**  ~/~/ Set AT+ADR=1.
692 +* **Example 2**: Downlink Payload: **2200FFFF**  ~/~/ Set AT+ADR=0.
536 536  
694 +(% style="display:none" %) (%%)
695 +
537 537  == 7.2 LoRa® Class ==
538 538  
698 +
539 539  Feature: Get or Set the Device Class(Currently only support class A, class C).
540 540  
541 -{{info}}
542 -**AT Command:AT+CLASS**
543 -{{/info}}
544 544  
702 +(% style="color:blue" %)**AT Command:  AT+CLASS**
703 +
545 545  (% border="1" style="background-color:#ffffcc; color:green; width:507.222px" %)
546 546  |=(% colspan="3" style="width: 504px;" %)AT+CLASS
547 547  |(% style="width:163px" %)**Command Example**|(% style="width:166px" %)**Function**|(% style="width:175px" %)**Response**
... ... @@ -549,17 +549,18 @@
549 549  OK
550 550  )))
551 551  |(% style="width:163px" %)AT+CLASS=C|(% style="width:166px" %)Set the Device Class.|(% style="width:175px" %)OK(((
552 -
553 553  )))
554 554  
713 +(% style="display:none" %) (%%)
714 +
555 555  == 7.3 Duty Cycle Setting ==
556 556  
557 -Feature: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing.
558 558  
559 -{{info}}
560 -**AT Command:AT+DCS**
561 -{{/info}}
718 +Feature: Get or Set the ETSI Duty Cycle setting** - 0**=disable, **1**=enable - Only for testing.
562 562  
720 +
721 +(% style="color:blue" %)**AT Command:  AT+DCS**
722 +
563 563  (% border="1" style="background-color:#ffffcc; color:green; width:515.222px" %)
564 564  |=(% colspan="3" style="width: 512px;" %)AT+DCS
565 565  |(% style="width:165px" %)**Command Example**|(% style="width:239px" %)**Function**|(% style="width:107px" %)**Response**
... ... @@ -567,17 +567,23 @@
567 567  OK
568 568  )))
569 569  |(% style="width:165px" %)AT+DCS=1|(% style="width:239px" %)Set the ETSI Duty Cycle setting.|(% style="width:107px" %)OK(((
570 -
571 571  )))
572 572  
732 +(% style="display:none" %) (%%)
733 +
573 573  == 7.4 Data Rate ==
574 574  
575 -Feature: Get or Set the Data Rate. (0-7 corresponding to DR_X) . Note: while set Data Rate, please use set Adptive Data Rate, ADR=0 first. otherwise device will response to server's ADR command and change the DR to the setting from server
576 576  
577 -{{info}}
578 -**AT Command: AT+DR**
579 -{{/info}}
737 +Feature: Get or Set the Data Rate. (0-7 corresponding to DR_X) .
580 580  
739 +(% style="color:red" %)
740 +**Notice:**
741 +
742 +* User need to set Adaptive Data Rate(ADR)=0 first. otherwise device will respond to server's ADR command and change the DR according to server auto-adjustment.
743 +* Data Rate specifies Spreading Factor. The mapping varies in different frequency bands. User can check this link for detail. [[rp2-1.0.3-lorawan-regional-parameters.pdf>>https://lora-alliance.org/resource_hub/rp2-1-0-3-lorawan-regional-parameters/]]
744 +
745 +(% style="color:blue" %)**AT Command: AT+DR**
746 +
581 581  (% border="1" style="background-color:#ffffcc; color:green; width:466.222px" %)
582 582  |=(% colspan="3" style="width: 463px;" %)AT+DR
583 583  |(% style="width:156px" %)**Command Example**|(% style="width:167px" %)**Function**|(% style="width:140px" %)**Response**
... ... @@ -588,24 +588,23 @@
588 588  
589 589  )))
590 590  
591 -{{info}}
592 -**Downlink Command: 0x2200aaFF**
593 -{{/info}}
757 +(% style="color:blue" %)**Downlink Command: 0x2200aaFF**
594 594  
595 -
596 596  If the downlink payload=220001FF, it means setting the data rate to 1, while type code is 22 00 aa FF.
597 597  
598 -* **Example 1**: Downlink Payload: **220001FF** ~/~/ Set AT+DR=1.
599 -* **Example 2**: Downlink Payload: **220000FF** ~/~/ Set AT+DR=0.
761 +* **Example 1**: Downlink Payload: **220001FF**  ~/~/ Set AT+DR=1.
762 +* **Example 2**: Downlink Payload: **220000FF**  ~/~/ Set AT+DR=0.
600 600  
764 +(% style="display:none" %) (%%)
765 +
601 601  == 7.5 Frame Counter Downlink ==
602 602  
768 +
603 603  Feature: Get or Set the Frame Counter Downlink.
604 604  
605 -{{info}}
606 -**AT Command:AT+FCD**
607 -{{/info}}
608 608  
772 +(% style="color:blue" %)**AT Command:  AT+FCD**
773 +
609 609  (% border="1" style="background-color:#ffffcc; color:green; width:693.222px" %)
610 610  |=(% colspan="3" style="width: 690px;" %)AT+FCD
611 611  |(% style="width:162px" %)**Command Example**|(% style="width:258px" %)**Function**|(% style="width:269px" %)**Response**
... ... @@ -614,8 +614,6 @@
614 614  )))
615 615  |(% style="width:162px" %)AT+FCD=10|(% style="width:258px" %)Set the Frame Counter Downlink.|(% style="width:269px" %)(System will write new value to FCD)(((
616 616  OK
617 -
618 -
619 619  )))
620 620  
621 621  == 7.6 Frame Counter Uplink ==
... ... @@ -622,10 +622,9 @@
622 622  
623 623  Feature: Get or Set the Frame Counter Uplink.
624 624  
625 -{{info}}
626 -**AT Command:AT+FCU**
627 -{{/info}}
628 628  
789 +(% style="color:blue" %)**AT Command:  AT+FCU**
790 +
629 629  (% border="1" style="background-color:#ffffcc; color:green; width:534.222px" %)
630 630  |=(% colspan="3" style="width: 531px;" %)AT+FCU
631 631  |(% style="width:177px" %)**Command Example**|(% style="width:239px" %)**Function**|(% style="width:113px" %)**Response**
... ... @@ -633,17 +633,18 @@
633 633  OK
634 634  )))
635 635  |(% style="width:177px" %)AT+FCU=10|(% style="width:239px" %)Set the Frame Counter Uplink.|(% style="width:113px" %)OK(((
636 -
637 637  )))
638 638  
800 +(% style="display:none" %) (%%)
801 +
639 639  == 7.7 Join Accept Delay1 ==
640 640  
804 +
641 641  Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms.
642 642  
643 -{{info}}
644 -**AT Command:AT+JN1DL**
645 -{{/info}}
646 646  
808 +(% style="color:blue" %)**AT Command:  AT+JN1DL**
809 +
647 647  (% border="1" style="background-color:#ffffcc; color:green; width:537.222px" %)
648 648  |=(% colspan="3" style="width: 534px;" %)AT+JN1DL
649 649  |(% style="width:164px" %)**Command Example**|(% style="width:229px" %)**Function**|(% style="width:140px" %)**Response**
... ... @@ -651,17 +651,18 @@
651 651  OK
652 652  )))
653 653  |(% style="width:164px" %)AT+JN1DL=10000|(% style="width:229px" %)Set the Join Accept Delay.|(% style="width:140px" %)OK(((
654 -
655 655  )))
656 656  
819 +(% style="display:none" %) (%%)
820 +
657 657  == 7.8 Join Accept Delay2 ==
658 658  
823 +
659 659  Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms.
660 660  
661 -{{info}}
662 -**AT Command:AT+JN2DL**
663 -{{/info}}
664 664  
827 +(% style="color:blue" %)**AT Command:  AT+JN2DL**
828 +
665 665  (% border="1" style="background-color:#ffffcc; color:green; width:538.222px" %)
666 666  |=(% colspan="3" style="width: 535px;" %)AT+JN2DL
667 667  |(% style="width:160px" %)**Command Example**|(% style="width:228px" %)**Function**|(% style="width:146px" %)**Response**
... ... @@ -669,17 +669,20 @@
669 669  OK
670 670  )))
671 671  |(% style="width:160px" %)AT+JN2DL=20000|(% style="width:228px" %)Set the Join Accept Delay.|(% style="width:146px" %)OK(((
672 -
673 673  )))
674 674  
838 +(% style="display:none" %) (%%)
839 +
675 675  == 7.9 Public Network Mode ==
676 676  
677 -Feature: Get or Set the public network mode. (0: off, 1: on)
678 678  
679 -{{info}}
680 -**AT Command:AT+PNM**
681 -{{/info}}
843 +Feature: Get or Set the public network mode. (0: off, 1: on). A Public LoRaWAN network use 0x34 as syncword. Default Settings; PNM=1
682 682  
845 +(% style="color:red" %)**Notice: If user build their own LoRaWAN server but still use syncword=0x34, this is still considered a public LoRaWAN network.**
846 +
847 +
848 +(% style="color:blue" %)**AT Command:  AT+PNM**
849 +
683 683  (% border="1" style="background-color:#ffffcc; color:green; width:667.222px" %)
684 684  |=(% colspan="3" style="width: 664px;" %)AT+PNM
685 685  |(% style="width:166px" %)**Command Example**|(% style="width:225px" %)**Function**|(% style="width:272px" %)**Response**
... ... @@ -686,20 +686,25 @@
686 686  |(% style="width:166px" %)AT+PNM=?|(% style="width:225px" %)Get the public network mode.|(% style="width:272px" %)1(((
687 687  OK
688 688  )))
689 -|(% style="width:166px" %)AT+PNM=1|(% style="width:225px" %)Set the public network mode.|(% style="width:272px" %)(System will write new value to PNM)(((
856 +|(% style="width:166px" %)AT+PNM=1|(% style="width:225px" %)(((
857 +Set the public network mode.
858 +
859 +Set syncword=0x34
860 +)))|(% style="width:272px" %)(System will write new value to PNM)(((
690 690  OK
691 691  
692 692  
693 693  )))
865 +|(% style="width:166px" %)AT+PNM=0|(% style="width:225px" %)Set to use private network autoset syncword=0x12|(% style="width:272px" %)
694 694  
695 695  == 7.10 Receive Delay1 ==
696 696  
869 +
697 697  Feature: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms
698 698  
699 -{{info}}
700 -**AT Command:AT+RX1DL**
701 -{{/info}}
702 702  
873 +(% style="color:blue" %)**AT Command: AT+RX1DL**
874 +
703 703  (% border="1" style="background-color:#ffffcc; color:green; width:408.222px" %)
704 704  |=(% colspan="3" style="width: 405px;" %)AT+RX1DL
705 705  |(% style="width:155px" %)**Command Example**|(% style="width:128px" %)**Function**|(% style="width:122px" %)**Response**
... ... @@ -710,14 +710,14 @@
710 710  
711 711  )))
712 712  
713 -== 7.11Receive Delay2 ==
885 +== 7.11 Receive Delay2 ==
714 714  
887 +
715 715  Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
716 716  
717 -{{info}}
718 -**AT Command:AT+RX2DL**
719 -{{/info}}
720 720  
891 +(% style="color:blue" %)**AT Command: AT+RX2DL**
892 +
721 721  (% border="1" style="background-color:#ffffcc; color:green; width:481.222px" %)
722 722  |=(% colspan="3" style="width: 478px;" %)AT+RX2DL
723 723  |(% style="width:175px" %)**Command Example**|(% style="width:152px" %)**Function**|(% style="width:150px" %)**Response**
... ... @@ -730,12 +730,12 @@
730 730  
731 731  == 7.12 Rx2 Window Data Rate ==
732 732  
905 +
733 733  Feature: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X)
734 734  
735 -{{info}}
736 -**AT Command:AT+RX2DR**
737 -{{/info}}
738 738  
909 +(% style="color:blue" %)**AT Command:  AT+RX2DR**
910 +
739 739  (% border="1" style="background-color:#ffffcc; color:green; width:525.222px" %)
740 740  |=(% colspan="3" style="width: 522px;" %)AT+RX2DR
741 741  |(% style="width:160px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:130px" %)**Response**
... ... @@ -748,12 +748,12 @@
748 748  
749 749  == 7.13 Rx2 Window Frequency ==
750 750  
923 +
751 751  Feature: Get or Set the Rx2 window frequency
752 752  
753 -{{info}}
754 -**AT Command:AT+RX2FQ**
755 -{{/info}}
756 756  
927 +(% style="color:blue" %)**AT Command:  AT+RX2FQ**
928 +
757 757  (% border="1" style="background-color:#ffffcc; color:green; width:587.222px" %)
758 758  |=(% colspan="3" style="width: 584px;" %)AT+RX2FQ
759 759  |(% style="width:183px" %)**Command Example**|(% style="width:240px" %)**Function**|(% style="width:160px" %)**Response**
... ... @@ -766,12 +766,14 @@
766 766  
767 767  == 7.14 Transmit Power ==
768 768  
941 +
769 769  Feature: Get or Set the Transmit Power(0-5, MAX:0, MIN:5, according to LoRaWAN Spec, or 40=10dB, 41 = 11dB, …, 50 = 20dB which is out of LoRaWAN spec. )
770 770  
771 -{{info}}
772 -**AT Command:AT+TXP**
773 -{{/info}}
944 +(% style="color:red" %)**Notice: Transmit Power might be changed by ADR from LoRaWAN server. So manually change TXP also remember to set AT+ADR=0 in sensor**
774 774  
946 +
947 +(% style="color:blue" %)**AT Command:  AT+TXP**
948 +
775 775  (% border="1" style="background-color:#ffffcc; color:green; width:465.222px" %)
776 776  |=(% colspan="3" style="width: 462px;" %)AT+TXP
777 777  |(% style="width:161px" %)**Command Example**|(% style="width:189px" %)**Function**|(% style="width:112px" %)**Response**
... ... @@ -786,17 +786,17 @@
786 786  
787 787  If the downlink payload=22000100, it means setting the TXP to 0.
788 788  
789 -* **Example 1**: Downlink Payload: **22000102** ~/~/ Set AT+TXP=2.
790 -* **Example 2**: Downlink Payload: **220000FF** ~/~/ Set AT+TXP=0.
963 +* **Example 1**: Downlink Payload: **22000102**  ~/~/ Set AT+TXP=2.
964 +* **Example 2**: Downlink Payload: **220000FF**  ~/~/ Set AT+TXP=0.
791 791  
792 792  == 7.15 RSSI of the Last Received Packet ==
793 793  
968 +
794 794  Feature: Get or Set the Rx2 window frequency
795 795  
796 -{{info}}
797 -**AT Command:AT+RSSI**
798 -{{/info}}
799 799  
972 +(% style="color:blue" %)**AT Command:AT+RSSI**
973 +
800 800  (% border="1" style="background-color:#ffffcc; color:green; width:557.222px" %)
801 801  |=(% colspan="3" style="width: 554px;" %)AT+RSSI
802 802  |(% style="width:164px" %)**Command Example**|(% style="width:289px" %)**Function**|(% style="width:100px" %)**Response**
... ... @@ -806,12 +806,12 @@
806 806  
807 807  == 7.16 SNR of the Last Received Packet ==
808 808  
983 +
809 809  Feature: Get the SNR of the last received packet
810 810  
811 -{{info}}
812 -**AT Command:AT+SNR**
813 -{{/info}}
814 814  
987 +(% style="color:blue" %)**AT Command:  AT+SNR**
988 +
815 815  (% border="1" style="background-color:#ffffcc; color:green; width:571.222px" %)
816 816  |=(% colspan="3" style="width: 568px;" %)AT+SNR
817 817  |(% style="width:164px" %)**Command Example**|(% style="width:290px" %)**Function**|(% style="width:113px" %)**Response**
... ... @@ -821,12 +821,12 @@
821 821  
822 822  == 7.17 Application Port ==
823 823  
998 +
824 824  Feature: Get or set the application port.
825 825  
826 -{{info}}
827 -**AT Command: AT+PORT**
828 -{{/info}}
829 829  
1002 +(% style="color:blue" %)**AT Command: AT+PORT**
1003 +
830 830  (% border="1" style="background-color:#ffffcc; color:green; width:500.222px" %)
831 831  |=(% colspan="3" style="width: 497px;" %)AT+PORT
832 832  |(% style="width:157px" %)**Command Example**|(% style="width:204px" %)**Function**|(% style="width:135px" %)**Response**
... ... @@ -835,25 +835,23 @@
835 835  )))
836 836  |(% style="width:157px" %)AT+PORT=21|(% style="width:204px" %)Set the application port|(% style="width:135px" %)OK
837 837  
838 -{{info}}
839 -**Downlink Command: 0x23**
840 -{{/info}}
1012 +(% style="color:blue" %)**Downlink Command: 0x23**
841 841  
842 842  Format: Command Code (0x23) followed by 1 bytes port value.
843 843  
844 844  If the downlink payload=2301, it means set the application port to 1, while type code is 23.
845 845  
846 -* **Example 1**: Downlink Payload: **2301** ~/~/ set the application port to 1
847 -* **Example 2**: Downlink Payload:** 2305** ~/~/ set the application port to 5
1018 +* **Example 1**: Downlink Payload: **2301**  ~/~/ set the application port to 1
1019 +* **Example 2**: Downlink Payload:** 2305**  ~/~/ set the application port to 5
848 848  
849 849  == 7.18 Single Channel Mode ==
850 850  
1023 +
851 851  Feature:Get or Set Frequency (Unit: Hz) for Single Channel Mode.
852 852  
853 -{{info}}
854 -**AT Command: AT+CHS**
855 -{{/info}}
856 856  
1027 +(% style="color:blue" %)**AT Command: AT+CHS**
1028 +
857 857  (% border="1" style="background-color:#ffffcc; color:green; width:603.222px" %)
858 858  |=(% colspan="3" style="width: 600px;" %)AT+CHS
859 859  |(% style="width:182px" %)**Command Example**|(% style="width:295px" %)**Function**|(% style="width:122px" %)**Response**
... ... @@ -864,12 +864,12 @@
864 864  
865 865  == 7.19 Eight Channel Mode ==
866 866  
1039 +
867 867  Feature: Get or Set eight channels mode,Only for US915,AU915,CN470.
868 868  
869 -{{info}}
870 -**AT Command: AT+CHE**
871 -{{/info}}
872 872  
1043 +(% style="color:blue" %)**AT Command: AT+CHE**
1044 +
873 873  (% border="1" style="background-color:#ffffcc; color:green; width:710.222px" %)
874 874  |=(% colspan="3" style="width: 707px;" %)AT+CHE
875 875  |(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response**
... ... @@ -880,25 +880,23 @@
880 880  )))
881 881  |(% style="width:160px" %)AT+CHE=1|(% style="width:198px" %)Set eight channels mode|(% style="width:349px" %)OK
882 882  
883 -{{info}}
884 -**Downlink Command: 0x24**
885 -{{/info}}
1055 +(% style="color:blue" %)**Downlink Command: 0x24 (LHT65,LHT65N Downlink Command:0x07)**
886 886  
887 887  Format: Command Code (0x24) followed by 1 bytes channel value.
888 888  
889 889  If the downlink payload=2401, it means set channel mode to 1, while type code is 24.
890 890  
891 -* **Example 1**: Downlink Payload: 2401 ~/~/ set channel mode to 1
892 -* **Example 2**: Downlink Payload: 2405 ~/~/ set channel mode to 5
1061 +* **Example 1**: Downlink Payload: 2401  ~/~/ set channel mode to 1
1062 +* **Example 2**: Downlink Payload: 2405  ~/~/ set channel mode to 5
893 893  
894 894  == 7.20 Get or Set RXwindows1 timeout ==
895 895  
896 -Feature:Get or Set the number of symbols to detect and timeout from RXwindow1(0 to 255).
897 897  
898 -{{info}}
899 -**AT Command: AT+RX1WTO**
900 -{{/info}}
1067 +Feature: Get or Set the number of symbols to detect and timeout from RXwindow1(0 to 255).
901 901  
1069 +
1070 +(% style="color:blue" %)**AT Command: AT+RX1WTO**
1071 +
902 902  (% border="1" style="background-color:#ffffcc; color:green; width:460.222px" %)
903 903  |=(% colspan="3" style="width: 457px;" %)AT+ RX1WTO
904 904  |(% style="width:163px" %)**Command Example**|(% style="width:201px" %)**Function**|(% style="width:93px" %)**Response**
... ... @@ -907,20 +907,32 @@
907 907  )))
908 908  |(% style="width:163px" %)AT+RX1WTO=60|(% style="width:201px" %)Set RXwindows1 timeout|(% style="width:93px" %)OK
909 909  
910 -AT+RX1TWO is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph.
1080 +(((
1081 +
911 911  
912 -[[image:image-20220511120050-1.png]]
913 913  
1084 +(% style="color:blue" %)**AT+RX1WTO**(%%) is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph.
1085 +
1086 +
1087 +)))
1088 +
1089 +[[image:image-20220526162535-1.png]]
1090 +
1091 +
1092 +(((
914 914  Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink.
915 915  
1095 +
1096 +)))
1097 +
916 916  == 7.21 Get or Set RXwindows2 timeout ==
917 917  
918 -Feature:Get or Set the number of symbols to detect and timeout from RXwindow2(0 to 255).
919 919  
920 -{{info}}
921 -**AT Command: AT+RX2WTO**
922 -{{/info}}
1101 +Feature: Get or Set the number of symbols to detect and timeout from RXwindow2(0 to 255).
923 923  
1103 +
1104 +(% style="color:blue" %)**AT Command: AT+RX2WTO**
1105 +
924 924  (% border="1" style="background-color:#ffffcc; color:green; width:497.222px" %)
925 925  |=(% colspan="3" style="width: 494px;" %)AT+ RX2WTO
926 926  |(% style="width:190px" %)**Command Example**|(% style="width:199px" %)**Function**|(% style="width:104px" %)**Response**
... ... @@ -931,12 +931,12 @@
931 931  
932 932  == 7.22 Setting up uplinkdwelltime (as923, au915) ==
933 933  
1116 +
934 934  Feature: Get or Set uplinkdwelltime
935 935  
936 -{{info}}
937 -**AT Command: AT+DWELLT**
938 -{{/info}}
939 939  
1120 +(% style="color:blue" %)**AT Command: AT+DWELLT**
1121 +
940 940  (% border="1" style="background-color:#ffffcc; color:green; width:497.222px" %)
941 941  |=(% colspan="3" style="width: 494px;" %)AT+DWELLT
942 942  |(% style="width:183px" %)**Command Example**|(% style="width:179px" %)**Function**|(% style="width:131px" %)**Response**
... ... @@ -945,23 +945,23 @@
945 945  )))
946 946  |(% style="width:183px" %)AT+DWELLT=0|(% style="width:179px" %)Set uplinkdwelltime|(% style="width:131px" %)OK
947 947  
948 -{{info}}
949 -**Downlink Command: 0x25**
950 -{{/info}}
1130 +(% style="color:blue" %)**Downlink Command: 0x25**
951 951  
952 952  Format: Command Code (0x25) followed by 1 bytes state value.
953 953  
954 954  If the downlink payload=2501, it means set uplinkdwelltime to 1, while type code is 25.
955 955  
956 -* **Example 1**: Downlink Payload: **2501** ~/~/ set uplinkdwelltime to 1
957 -* **Example 2**: Downlink Payload: **2500** ~/~/ set uplinkdwelltime to 0
1136 +* **Example 1**: Downlink Payload: **2501**  ~/~/ set uplinkdwelltime to 1
1137 +* **Example 2**: Downlink Payload: **2500**  ~/~/ set uplinkdwelltime to 0
958 958  
959 959  == 7.23 Set Packet Receiving Response Level ==
960 960  
1141 +
961 961  Feature: Get or Set packet receiving response level. This feature is used to set compatible with different LoRaWAN servers. If RPL doesn;t match , user will see strange message in the server portal.
962 962  
963 -RPL value:
964 964  
1145 +**RPL value:**
1146 +
965 965  * **AT+RPL=0:** Device won't immediately reply any downlink commands from platform.
966 966  * **AT+RPL=1:** Device will immediately reply message to Unconfirmed Data Down. Payload is 0x00.
967 967  * **AT+RPL=2:** Device will immediately reply message to Confirmed Data Down. Payload is 0x00 and requied response header for this command.
... ... @@ -968,15 +968,13 @@
968 968  * **AT+RPL=3:** Device will immediately reply message to MAC Command. Payload is 0x00 and requied response header for this command.
969 969  * **AT+RPL=4: **Device will immediately reply message to Confirmed Data Down & MAC Command. Payload is 0x00 and requied response header for these two commands.
970 970  
971 -Case Analyes:
1153 +**Case Analyes:**
972 972  
973 973  * For Class A devices, AT+RPL=0 is ok. that is defaut settings in software.
974 974  * For Class C devices used in ChirpStack, need to set AT+RPL=4 because Chirpstack require immedietely reply message to MAC Command.
975 975  * For Class C devices used in TTI, need to set AT+RPL=4 because TTI require immediately reply message to Confirmed Data Down & MAC Command.
976 976  
977 -{{info}}
978 -**AT Command: AT+RPL**
979 -{{/info}}
1159 +(% style="color:blue" %)**AT Command: AT+RPL**
980 980  
981 981  (% border="1" style="background-color:#ffffcc; color:green; width:536.222px" %)
982 982  |=(% colspan="3" style="width: 533px;" %)AT+RPL
... ... @@ -986,32 +986,158 @@
986 986  )))
987 987  |(% style="width:160px" %)AT+RPL=0|(% style="width:263px" %)Set packet receiving response level|(% style="width:109px" %)OK
988 988  
989 -{{info}}
990 -**Downlink Command: 0x21**
991 -{{/info}}
1169 +(% style="color:blue" %)**Downlink Command: 0x21**
992 992  
993 993  Format: Command Code (0x21) followed by 1 bytes level value.
994 994  
995 995  If the downlink payload=2101, it means set packet receiving response level to 1, while type code is 21.
996 996  
997 -* **Example 1**: Downlink Payload: **2101** ~/~/ set packet receiving response level to 1
998 -* **Example 2**: Downlink Payload: **2102** ~/~/ set packet receiving response level to 2
1175 +* **Example 1**: Downlink Payload: **2101**  ~/~/ set packet receiving response level to 1
1176 +* **Example 2**: Downlink Payload: **2102**  ~/~/ set packet receiving response level to 2
999 999  
1178 +== 7.24 Controls NBTrans in unconfirmed uplink mode(LWS007 NBTrans:Set retransmission packets) ==
1179 +
1180 +
1181 +(% style="color:blue" %)**AT Command: AT+SETMAXNBTRANS **
1182 +
1183 +(% border="1" style="background-color:#ffffcc; color:green; width:589px" %)
1184 +|=(% colspan="3" style="width: 586px;" %)AT+**SETMAXNBTRANS**
1185 +|(% style="width:227px" %)**Command Example**|(% style="width:300px" %)**Function**|(% style="width:87px" %)**Response**
1186 +|(% style="width:227px" %)**AT+SETMAXNBTRANS=1,0**|(% style="width:300px" %)Value1: set the maximum NBTrans.|(% style="width:87px" %)1(((
1187 +OK
1188 +)))
1189 +|(% style="width:227px" %)**AT+SETMAXNBTRANS=?,1**|(% style="width:300px" %)(((
1190 +value2: 0: uplink fcnt doesn't change for each NBTrans;
1191 +
1192 +1: uplink fcnt increase by 1 for each NBTrans.
1193 +)))|(% style="width:87px" %)(((
1194 +1
1195 +
1196 +OK
1197 +)))
1198 +
1199 +(% style="color:blue" %)**Downlink Command: 0x33**
1200 +
1201 +Format: Command Code (0x33) followed by 2 bytes mode value.
1202 +
1203 +If the downlink payload=330100, it means set end node to use confirm mode, while type code is 33.
1204 +
1205 +* Example 1: Downlink Payload: 330100  ~/~/ Set AT+SETMAXNBTRANS=1,0
1206 +* Example 2: Downlink Payload: 330201  ~/~/ Set AT+SETMAXNBTRANS=2,1
1207 +
1208 +== 7.25 Device offline rejoining (LWS007) ==
1209 +
1210 +
1211 +(% style="color:blue" %)**AT Command: AT+DDETECT**
1212 +
1213 +AT+DDETECT=<Flag>,<ACK_Timout_1>,<ACK_Timout_2> (Default Value: AT+DDETECT=1,1440,2880)
1214 +
1215 +* ACK_Timout_1: Unit: min
1216 +* ACK_Timout_2: Unit: min
1217 +
1218 +(% border="1" style="background-color:#ffffcc; color:green; width:710.222px" %)
1219 +|=(% colspan="3" style="width: 707px;" %)AT+**DDETECT**
1220 +|(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response**
1221 +|(% style="width:160px" %)(((
1222 +AT+DDETECT=1,1440,2880
1223 +
1224 +value1
1225 +)))|(% style="width:198px" %)Enable online detect|(% style="width:349px" %)(((
1226 +1
1227 +
1228 +OK
1229 +)))
1230 +|(% style="width:160px" %)(((
1231 +AT+DDETECT=1,?,2880
1232 +
1233 +value2
1234 +)))|(% style="width:198px" %)Online detection packet sending time|(% style="width:349px" %)(((
1235 +
1236 +
1237 +OK
1238 +)))
1239 +|(% style="width:160px" %)(((
1240 +AT+DDETECT=1,1440,?
1241 +
1242 +value3
1243 +)))|(% style="width:198px" %)Process rejoin|(% style="width:349px" %)(((
1244 +
1245 +
1246 +OK
1247 +)))
1248 +
1249 +(% style="color:blue" %)**Downlink Command: 0x32**
1250 +
1251 +Format: Command Code (0x32) followed by 2 bytes mode value.
1252 +
1253 +If the downlink payload=320105A00B40, it means set end node to use confirm mode, while type code is 32.
1254 +
1255 +* **Example 1:** Downlink Payload: 320105A00B40  ~/~/ Set AT+DDETECT=1,1440,2880
1256 +** 0x01 : Flag
1257 +** 0x05A0: ACK_Timout_1 : 1440minutes (24 hours)
1258 +** 0x0B40: ACK_Timout_2 : 2880minutes (48 hours)
1259 +** **Explain**: Enable Online Detect, if end node doesn't receive any downlink within ACK_Timout_1( 1440 minutes or 24 hours). End node will use confirmed uplink to send packets during ACK_Timout_1 (the 24th hour) to ACK_Timout_2 ( the 48th hour). If from the 24th to 48th hour, end node got an downlink from server, it will switch back to unconfirmed uplink. end node will restart ACK_Timout_1. If from the 24th to 48th hour, end node still not got any downlink, means device doesn't get ACK from server within last 48 hours. Device will process rejoin, rejoin request interval is AT+RJTDC period. For AU915/ US915, device will use the sub-band used for last join.
1260 +
1261 +== 7.26 Request the server to send an ACK ==
1262 +
1263 +
1264 +(% style="color:blue" %)**AT Command: AT+PNACKMD**
1265 +
1266 +(% border="1" style="background-color:#ffffcc; color:green; width:536.222px" %)
1267 +|=(% colspan="3" style="width: 533px;" %)**AT+PNACKMD**
1268 +|(% style="width:160px" %)**Command Example**|(% style="width:263px" %)**Function**|(% style="width:109px" %)**Response**
1269 +|(% style="width:160px" %)**AT+PNACKMD=1**|(% style="width:263px" %)If the node uploads the ACK as confirm, it will request the server to send an ACK. If the server ack is not received, the node will upload the packets that have not received the ACK the next time it receives the ACK|(% style="width:109px" %)1(((
1270 +OK
1271 +)))
1272 +|(% style="width:160px" %)**AT+PNACKMD=0**|(% style="width:263px" %)off request the server to send an ACK|(% style="width:109px" %)(((
1273 +0
1274 +
1275 +OK
1276 +)))
1277 +
1278 +== 7.27 Adjust network rejoining interval ==
1279 +
1280 +
1281 +(% style="color:blue" %)**AT Command: AT+RJTDC**
1282 +
1283 +(% border="1" style="background-color:#ffffcc; color:green; width:727.222px" %)
1284 +|=(% colspan="3" style="width: 724px;" %)AT+RJTDC
1285 +|(% style="width:165px" %)**Command Example**|(% style="width:227px" %)**Function**|(% style="width:329px" %)**Response**
1286 +|(% style="width:165px" %)AT+RJTDC=?|(% style="width:227px" %)Show the ReJoin data transmission interval in min|(% style="width:329px" %)30(((
1287 +OK
1288 +
1289 +the interval is 30 min
1290 +)))
1291 +|(% style="width:165px" %)AT+RJTDC=60|(% style="width:227px" %)Set the ReJoin data transmission interval in min|(% style="width:329px" %)OK(((
1292 +Set the ReJoin data transmission interval to 60 min
1293 +)))
1294 +
1295 +(% style="color:blue" %)**Downlink Command: 0x26**
1296 +
1297 +Format: Command Code (0x26) followed by 2 bytes mode value.
1298 +
1299 +If the downlink payload=26000A, it means set end node to use confirm mode, while type code is 26.
1300 +
1301 +* **Example 1:** Downlink Payload: 26000A  ~/~/ Set AT+RJTDC=10
1302 +* **Example 2: **Downlink Payload: 260002  ~/~/ Set AT+RJTDC=2
1303 +
1000 1000  = 8. AT Commands Combination =
1001 1001  
1002 1002  == 8.1 Set a fix RX2DR for downlink window ==
1003 1003  
1004 -* **AT+ADR=0 **~-~-> Disable ADR first
1005 -* **AT+RX2DR=xxxx** ~-~-> Set xxxx to your wanted DataRate
1006 1006  
1309 +* (% style="color:blue" %)**AT+ADR=0             **(%%) **~-~->**  Disable ADR first
1310 +* (% style="color:blue" %)**AT+RX2DR=xxxx**   (%%) **~-~->**  Set xxxx to your wanted DataRate
1311 +
1007 1007  == 8.2 Use Downlink Command to set a fix uplink DR ==
1008 1008  
1009 -{{info}}
1010 -**Downlink Command: 0x22000500**
1011 -{{/info}}
1012 1012  
1013 -Same as:
1315 +(% style="color:blue" %)**Downlink Command: 0x22000500**
1014 1014  
1015 -* AT+ADR=0 [[Reference>>http://8.211.40.43:8080/xwiki/bin/view/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#Adaptive_Data_Rate]]
1016 -* AT+DR=5 [[Reference>>url:https://wiki.dragino.com/index.php/End_Device_Downlink_Command#Data_Rate]]
1017 -* AT+TXP=0 [[Reference>>url:https://wiki.dragino.com/index.php/End_Device_Downlink_Command#Transmit_Power]]
1317 +**Same as:**
1318 +
1319 +* AT+ADR=0  [[Reference>>||anchor="H7.1AdaptiveDataRate"]]
1320 +* AT+DR=5  [[Reference>>||anchor="H7.4DataRate"]]
1321 +* AT+TXP=0  [[Reference>>||anchor="H7.14TransmitPower"]]
1322 +
1323 +
image-20220526162535-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +149.4 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0