Changes for page Different methods to detect water and liquid level
Last modified by Edwin Chen on 2025/06/26 11:53
From version 9.1
edited by Edwin Chen
on 2022/12/17 17:07
on 2022/12/17 17:07
Change comment:
Uploaded new attachment "image-20221217170756-1.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -2,15 +2,19 @@ 2 2 3 3 {{toc/}} 4 4 5 -= Overview = 6 6 6 + 7 += 1. Overview = 8 + 9 + 7 7 This URL introduce different methods to detect the water / liquid level. 8 8 9 9 10 -= Flow switch = 13 += 2. Flow switch = 11 11 12 -== How it works == 15 +== 2.1 How it works == 13 13 17 + 14 14 Below is an example of flow switch. and product link: 15 15 16 16 [[https:~~/~~/www.amazon.com/Float-Switch-Septic-System-Sump/dp/B0064BHEVM/ref=sr_1_5?crid=2PCMSD63FBP42&keywords=float%2Bswitch&qid=1671230997&refinements=p_72%3A1248909011&rnid=1248907011&s=hi&sprefix=float%2Bswitch%2Caps%2C155&sr=1-5&th=1 >>https://www.amazon.com/Float-Switch-Septic-System-Sump/dp/B0064BHEVM/ref=sr_1_5?crid=2PCMSD63FBP42&keywords=float%2Bswitch&qid=1671230997&refinements=p_72%3A1248909011&rnid=1248907011&s=hi&sprefix=float%2Bswitch%2Caps%2C155&sr=1-5&th=1]] ... ... @@ -17,6 +17,7 @@ 17 17 18 18 [[image:image-20221217164157-1.png||height="329" width="486"]] 19 19 24 + 20 20 [[image:image-20221217164432-3.png||height="282" width="501"]][[image:image-20221217164337-2.png||height="279" width="431"]] 21 21 22 22 The switch will switch on/off to show if the water / liquid has dedicate level. ... ... @@ -27,13 +27,61 @@ 27 27 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/#H2.4.5DigitalInterrupt >>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/#H2.4.5DigitalInterrupt]] 28 28 29 29 30 -== Advantage & Disadvantage == 35 +== 2.2 Advantage & Disadvantage == 31 31 32 -**Advantage** : Reliable , Easy to install & Immue to different environment. 33 33 34 -** Disadvantage**:Only betodetectonespeicifylevel.Notable to detectfullrangeof water.38 +(% style="color:blue" %)**Advantage**(%%) : Reliable , Easy to install & Immue to different environment. 35 35 40 +(% style="color:red" %)**Disadvantage**(%%): Only be able to detect one speicify level. Not able to detect full range of water. 36 36 37 37 43 += 3. Ultrasonic Sensor = 38 38 45 +== 3.1 How it works? == 46 + 47 + 48 +Such as [[LDDS75>>https://www.dragino.com/products/distance-level-sensor/item/161-ldds75.html]] / [[LDDS45>>https://www.dragino.com/products/distance-level-sensor/item/191-ldds45.html]]. They are using ultrasonic technologic to detect the distance between the probe and a flat object such as water level. 49 + 50 +Below is photo and URL shows how Ultrasonic Sensor works to detect Water Level 51 + 52 +[[https:~~/~~/www.electricalvolt.com/2022/06/ultrasonic-level-transmitter-working/ >>https://www.electricalvolt.com/2022/06/ultrasonic-level-transmitter-working/]] 53 + 54 +[[image:image-20221217170756-1.png||height="465" width="539"]] 55 + 56 + 57 +When choose the ultrasonic sensor, we need to check the measure range , blind spot and angel to fit the tank. 58 + 59 +An important notice, if there are moisture accumulated in the sense area of Ultrasonic Probe of LDDS75/LDDS45. the reading will become invalid. 60 + 61 + 62 +== 3.2 Advantage & Disadvantage == 63 + 64 + 65 +(% style="color:blue" %)**Advantage**(%%) : Able to detect the level. Good Accurancy. 66 + 67 +(% style="color:red" %)**Disadvanage**(%%): Wrong reading when probe is block by moisture or other stuff. Affect by temperature. 68 + 69 + 70 += 4. Pressure Sensor = 71 + 72 +== 4.1 How it works? == 73 + 74 + 75 +Pressure Sensor such as [[PS-LB>>https://www.dropbox.com/sh/eshhuk347xi1ce4/AAA4LUmYc2ITayfJUVsqK3wya?dl=0]] measures the pressure of the air / gas / liquid so can calcualte the liquid level. 76 + 77 +there are two types , (% style="color:blue" %)**Thread type** (%%)and (% style="color:blue" %)**Immersion type**(%%). as below: 78 + 79 + 80 +[[image:image-20221228143643-1.png||height="223" width="312"]] [[image:image-20221228144206-2.png||height="256" width="335"]] 81 + 82 + 83 +== 4.2 Advantage & Disadvantage == 84 + 85 + 86 +(% style="color:blue" %)**Advantage**(%%) : Able to detect air / gas / liquid pressure level. Immue to factors such as moisture / blocking. etc. Flexible for installation for 87 + 88 +(% style="color:red" %)**Disadvanage **(%%): 89 + 90 + 91 + 39 39
- image-20221228143643-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +166.7 KB - Content
- image-20221228144206-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.8 KB - Content