... ... @@ -61,6 +61,7 @@
61 61  * If the measure range , blind spot and angel fit the tank installation and measurement requirement.
62 62  * Make sure the liquid on the tank will not touch the top so touch the sensor.
63 63  * If there are moisture accumulated in the sense area of probe of Ultrosonic Sensor or LiDAR ToF. the reading will become invalid.
64 +* Some liquid has
64 64  
65 65  
66 66  
... ... @@ -102,8 +102,13 @@
102 102  
103 103  When there is liquid or none-liquid, the object will shows different capacitance. We can use Capacitance reading to check if the position has liquid or not.
104 104  
106 +[[image:1750816596142-762.png||height="323" width="206"]][[image:1750816492900-386.png||height="347" width="433"]]
105 105  
106 -[[image:1750816492900-386.png||height="347" width="433"]]
107 107  
109 +== 5.2 Advantage & Disadvantage ==
108 108  
111 +(% style="color:blue" %)**Advantage**(%%) :  Easy Installation, low power consumption
112 +
113 +(% style="color:red" %)**Disadvanage **(%%): Can only check certain level. not able to give detail reading.