Changes for page Different methods to detect water and liquid level
Last modified by Edwin Chen on 2025/06/26 11:53
From version 14.14
edited by Edwin Chen
on 2025/06/25 09:28
on 2025/06/25 09:28
Change comment:
There is no comment for this version
To version 14.23
edited by Edwin Chen
on 2025/06/25 09:30
on 2025/06/25 09:30
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -44,19 +44,22 @@ 44 44 45 45 == 3.1 How it works? == 46 46 47 -These type sensors normally install on the top of the liquid leve and use different technology (Ultrasonic/ LiDAR ToF / MicroWave Ridar) to check the liqui 47 +These type sensors normally install on the top of the liquid leve and use different technology (Ultrasonic/ LiDAR ToF / MicroWave Ridar) to check the liquid level. 48 48 49 -Such as [[LDDS75>>https://www.dragino.com/products/distance-level-sensor/item/161-ldds75.html]] / [[LDDS45>>https://www.dragino.com/products/distance-level-sensor/item/191-ldds45.html]]. They are using ultrasonic technologic to detect the distance between the probe and a flat object such as water level. 50 50 51 - BelowsphotoandURLshowshowUltrasonicSensorworks to detectWaterLevel50 +For example: [[LDDS75>>https://www.dragino.com/products/distance-level-sensor/item/161-ldds75.html]] / [[LDDS45>>https://www.dragino.com/products/distance-level-sensor/item/191-ldds45.html]] are using ultrasonic technologic to detect the distance between the probe and a flat object such as water level. 52 52 52 +Below is photo and URL shows how Ultrasonic Sensor works to detect Water Level. LiDAR ToF and MicroWave RiDar are similiar. 53 + 53 53 [[https:~~/~~/www.electricalvolt.com/2022/06/ultrasonic-level-transmitter-working/ >>https://www.electricalvolt.com/2022/06/ultrasonic-level-transmitter-working/]] 54 54 55 55 [[image:image-20221217170756-1.png||height="465" width="539"]] 56 56 57 57 58 -When choose the ultrasonicsensor,we needto checkthe measurenge , blind spot andangel to fit the tank.59 +When choose the these sensors, the consideration are: 59 59 61 +* If the measure range , blind spot and angel fit the tank installa 62 + 60 60 An important notice, if there are moisture accumulated in the sense area of Ultrasonic Probe of LDDS75/LDDS45. the reading will become invalid. 61 61 62 62