Changes for page Debug NB-IoT Connection

Last modified by Xiaoling on 2024/08/19 16:09

From version 7.2
edited by Xiaoling
on 2022/07/22 16:59
Change comment: There is no comment for this version
To version 7.6
edited by Xiaoling
on 2023/04/21 11:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,13 +1,15 @@
1 1  = **For BC95-G** =
2 2  
3 +----
3 3  
5 +
4 4  (% style="color:blue" %)**1. Check the reason why you can't access the network:**
5 5  
6 -1) AT+CEREG=5
8 +(% style="color:#037691" %)**1) AT+CEREG=5**
7 7  
8 -2) AT+CEREG? ~/~/This process may be longer, please repeat the input
10 +(% style="color:#037691" %)**2) AT+CEREG?**  (%%) ~/~/  This process may be longer, please repeat the input
9 9  
10 -3) Mainly check the two parameters cause_type and reject_case
12 +(% style="color:#037691" %)**3) Mainly check the two parameters (% style="color:red" %)cause_type and (% style="color:red" %)reject_case**
11 11  
12 12  
13 13  [[image:image-20220530093747-3.png]]
... ... @@ -15,14 +15,15 @@
15 15  
16 16  (% style="color:blue" %)**2. Network access operation:**
17 17  
18 -1) AT+CFUN=0
20 +(% style="color:#037691" %)1) AT+CFUN=0
19 19  
20 -2) AT+NBAND=X ~/~/X means the local frequency band number
22 +(% style="color:#037691" %)2) AT+NBAND=X  (%%) ~/~/  X means the local frequency band number
21 21  
22 -3) AT+NRB
24 +(% style="color:#037691" %)3) AT+NRB
23 23  
24 -4) After waiting for a period of time, you can use AT+CSQ to query the network access
26 +(% style="color:#037691" %)4) After waiting for a period of time, you can use (% style="color:red" %)AT+CSQ (%%)to query the network access
25 25  
28 +
26 26  [[image:image-20220530093821-4.png]]
27 27  
28 28