Changes for page Debug NB-IoT Connection
Last modified by Xiaoling on 2024/08/19 16:09
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,29 +1,36 @@ 1 -= For BC95-G = 1 += **For BC95-G** = 2 2 3 -~1. Check the reason why you can't access the network: 4 4 4 +(% style="color:blue" %)**1. Check the reason why you can't access the network:** 5 + 5 5 1) AT+CEREG=5 6 6 7 -2) AT+CEREG? ~/~/This process may be longer, please repeat the input 8 +2) AT+CEREG? ~/~/This process may be longer, please repeat the input 8 8 9 9 3) Mainly check the two parameters cause_type and reject_case 10 10 11 -[[image:https://wiki.dragino.com/images/1/19/BC-95-G1.png||alt="BC-95-G1.png" height="366" width="558"]] 12 12 13 - 2. Networkaccess operation:13 +[[image:image-20220530093747-3.png]] 14 14 15 + 16 + 17 +(% style="color:blue" %)**2. Network access operation:** 18 + 15 15 1) AT+CFUN=0 16 16 17 -2) AT+NBAND=X ~/~/X means the local frequency band number 21 +2) AT+NBAND=X ~/~/X means the local frequency band number 18 18 19 19 3) AT+NRB 20 20 21 21 4) After waiting for a period of time, you can use AT+CSQ to query the network access 22 22 23 -[[image:https://wiki.dragino.com/images/2/24/BC-95-G2.png||alt="BC-95-G2.png" height="365" width="558"]] 24 24 25 - Remarks:28 +[[image:image-20220530093821-4.png]] 26 26 30 + 31 + 32 +(% style="color:blue" %)**Remarks:** 33 + 27 27 ~1. The operating voltage of the SIM card used must be less than 3.0V 28 28 29 29 2. The network access time varies with the signal strength