<
From version < 13.8 >
edited by Xiaoling
on 2022/07/23 17:27
To version < 13.2 >
edited by Xiaoling
on 2022/05/26 11:47
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,21 +1,17 @@
1 -**~ Table of Contents:**
1 +**~ Contents:**
2 2  
3 3  {{toc/}}
4 4  
5 5  
6 -= 1.  Introduction =
6 += 1. Introduction =
7 7  
8 -
9 9  Here list some notice when connect to Senra.
10 10  
11 11  
12 -= 2.  Notice for Gateway =
11 += 2. Notice for Gateway =
13 13  
14 -
15 15  (((
16 16  After register an account in Senra, ask their support to approval your gateway: refer ths link [[https:~~/~~/docs.senraco.io/dev/gw/SemtechPacketForwarder/>>url:https://docs.senraco.io/dev/gw/SemtechPacketForwarder/]] for gateway instruction of Senra.
17 -
18 -
19 19  )))
20 20  
21 21  [[image:image-20220524181429-1.jpeg]]
... ... @@ -26,13 +26,10 @@
26 26  * The Gateway EUI must match the Approval Gateway EUI in above screen shot
27 27  * The keep alive status set to 300 seconds. Default 30 seconds is too short to Senra
28 28  
29 -
30 30  [[image:image-20220524181455-2.png]]
31 31  
32 -
33 33  Configure the Gateway with correct settings.
34 34  
35 -
36 36  Gateway should be Active after have internet connection. like below:
37 37  
38 38  [[image:image-20220526114401-1.png||height="395" width="1337"]]
... ... @@ -40,16 +40,12 @@
40 40  Configure the Gateway with correct settings.
41 41  
42 42  
36 += 3. Notice for End node =
43 43  
44 -= 3.  Notice for End node =
38 +== 3.1 Set up for OTAA mode ==
45 45  
46 -== 3. Set up for OTAA mode ==
40 +== 3.2 Set up for ABP Mode ==
47 47  
48 -
49 -
50 -== 3.2  Set up for ABP Mode ==
51 -
52 -
53 53  (((
54 54  (((
55 55  ABP Mode devices has to be IN868 frequency band as well, User can use ABP mode to update data.
... ... @@ -58,15 +58,13 @@
58 58  
59 59  (((
60 60  (((
61 -For Dragino End Node, user can access to the device console and run AT Command "(% style="color:blue" %)**AT+NJM=0**(%%)" to set it to ABP mode.
50 +For Dragino End Node, user can access to the device console and run AT Command "**AT+NJM=0**" to set it to ABP mode.
62 62  )))
63 63  )))
64 64  
65 65  (((
66 66  (((
67 -User can know the keys by run (% style="color:blue" %)**AT+CFG**.
68 -
69 -
56 +User can know the keys by run **AT+CFG**.
70 70  )))
71 71  )))
72 72  
... ... @@ -80,19 +80,17 @@
80 80  
81 81  Create ABP Device
82 82  
70 +And input the keys:
83 83  
84 -**(% style="color:blue" %)And input the keys:**
72 +* Device EUI : Use the value from AT+DEUI
73 +* Device ADDR: Use the value from AT+DADDR
74 +* Application session key: Use the value from AT+APPSKEY
75 +* Network Session Key: Use the value from AT+NWKSKEY
85 85  
86 -* **(% style="color:#037691" %)Device EUI : ** (%%) Use the value from AT+DEUI
87 -* **(% style="color:#037691" %)Device ADDR:**(%%)  Use the value from AT+DADDR
88 -* **(% style="color:#037691" %)Application session key:** (%%) Use the value from AT+APPSKEY
89 -* **(% style="color:#037691" %)Network Session Key:** (%%) Use the value from AT+NWKSKEY
90 -
91 91  [[image:image-20220524181549-6.png]]
92 92  
93 93  Create ABP Device
94 94  
95 -
96 96  After Successfule uplink, User will be to see the activity:
97 97  
98 98  [[image:image-20220526114506-2.png]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0