<
From version < 13.6 >
edited by Xiaoling
on 2022/05/30 14:36
To version < 13.8 >
edited by Xiaoling
on 2022/07/23 17:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,17 +1,21 @@
1 -**~ Contents:**
1 +**~ Table of Contents:**
2 2  
3 3  {{toc/}}
4 4  
5 5  
6 -= 1. Introduction =
6 += 1.  Introduction =
7 7  
8 +
8 8  Here list some notice when connect to Senra.
9 9  
10 10  
11 -= 2. Notice for Gateway =
12 += 2.  Notice for Gateway =
12 12  
14 +
13 13  (((
14 14  After register an account in Senra, ask their support to approval your gateway: refer ths link [[https:~~/~~/docs.senraco.io/dev/gw/SemtechPacketForwarder/>>url:https://docs.senraco.io/dev/gw/SemtechPacketForwarder/]] for gateway instruction of Senra.
17 +
18 +
15 15  )))
16 16  
17 17  [[image:image-20220524181429-1.jpeg]]
... ... @@ -22,10 +22,13 @@
22 22  * The Gateway EUI must match the Approval Gateway EUI in above screen shot
23 23  * The keep alive status set to 300 seconds. Default 30 seconds is too short to Senra
24 24  
29 +
25 25  [[image:image-20220524181455-2.png]]
26 26  
32 +
27 27  Configure the Gateway with correct settings.
28 28  
35 +
29 29  Gateway should be Active after have internet connection. like below:
30 30  
31 31  [[image:image-20220526114401-1.png||height="395" width="1337"]]
... ... @@ -33,12 +33,16 @@
33 33  Configure the Gateway with correct settings.
34 34  
35 35  
36 -= 3. Notice for End node =
37 37  
38 -== 3.1 Set up for OTAA mode ==
44 += 3.  Notice for End node =
39 39  
40 -== 3.2 Set up for ABP Mode ==
46 +== 3. Set up for OTAA mode ==
41 41  
48 +
49 +
50 +== 3.2  Set up for ABP Mode ==
51 +
52 +
42 42  (((
43 43  (((
44 44  ABP Mode devices has to be IN868 frequency band as well, User can use ABP mode to update data.
... ... @@ -47,13 +47,15 @@
47 47  
48 48  (((
49 49  (((
50 -For Dragino End Node, user can access to the device console and run AT Command "**AT+NJM=0**" to set it to ABP mode.
61 +For Dragino End Node, user can access to the device console and run AT Command "(% style="color:blue" %)**AT+NJM=0**(%%)" to set it to ABP mode.
51 51  )))
52 52  )))
53 53  
54 54  (((
55 55  (((
56 -User can know the keys by run **AT+CFG**.
67 +User can know the keys by run (% style="color:blue" %)**AT+CFG**.
68 +
69 +
57 57  )))
58 58  )))
59 59  
... ... @@ -68,12 +68,12 @@
68 68  Create ABP Device
69 69  
70 70  
71 -And input the keys:
84 +**(% style="color:blue" %)And input the keys:**
72 72  
73 -* Device EUI : Use the value from AT+DEUI
74 -* Device ADDR: Use the value from AT+DADDR
75 -* Application session key: Use the value from AT+APPSKEY
76 -* Network Session Key: Use the value from AT+NWKSKEY
86 +* **(% style="color:#037691" %)Device EUI : ** (%%) Use the value from AT+DEUI
87 +* **(% style="color:#037691" %)Device ADDR:**(%%)  Use the value from AT+DADDR
88 +* **(% style="color:#037691" %)Application session key:** (%%) Use the value from AT+APPSKEY
89 +* **(% style="color:#037691" %)Network Session Key:** (%%) Use the value from AT+NWKSKEY
77 77  
78 78  [[image:image-20220524181549-6.png]]
79 79  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0