<
From version < 12.1 >
edited by Xiaoling
on 2022/05/26 11:45
To version < 13.8 >
edited by Xiaoling
on 2022/07/23 17:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,16 +1,21 @@
1 -**~ Contents:**
1 +**~ Table of Contents:**
2 2  
3 3  {{toc/}}
4 4  
5 5  
6 -= 1. Introduction =
6 += 1.  Introduction =
7 7  
8 +
8 8  Here list some notice when connect to Senra.
9 9  
10 -= 2. Notice for Gateway =
11 11  
12 += 2.  Notice for Gateway =
13 +
14 +
12 12  (((
13 13  After register an account in Senra, ask their support to approval your gateway: refer ths link [[https:~~/~~/docs.senraco.io/dev/gw/SemtechPacketForwarder/>>url:https://docs.senraco.io/dev/gw/SemtechPacketForwarder/]] for gateway instruction of Senra.
17 +
18 +
14 14  )))
15 15  
16 16  [[image:image-20220524181429-1.jpeg]]
... ... @@ -21,22 +21,30 @@
21 21  * The Gateway EUI must match the Approval Gateway EUI in above screen shot
22 22  * The keep alive status set to 300 seconds. Default 30 seconds is too short to Senra
23 23  
29 +
24 24  [[image:image-20220524181455-2.png]]
25 25  
32 +
26 26  Configure the Gateway with correct settings.
27 27  
35 +
28 28  Gateway should be Active after have internet connection. like below:
29 29  
30 -[[image:image-20220524181508-3.png]]
38 +[[image:image-20220526114401-1.png||height="395" width="1337"]]
31 31  
32 32  Configure the Gateway with correct settings.
33 33  
34 -= 3. Notice for End node =
35 35  
36 -== 3.1 Set up for OTAA mode ==
37 37  
38 -== 3.2 Set up for ABP Mode ==
44 += 3.  Notice for End node =
39 39  
46 +== 3.1  Set up for OTAA mode ==
47 +
48 +
49 +
50 +== 3.2  Set up for ABP Mode ==
51 +
52 +
40 40  (((
41 41  (((
42 42  ABP Mode devices has to be IN868 frequency band as well, User can use ABP mode to update data.
... ... @@ -45,13 +45,15 @@
45 45  
46 46  (((
47 47  (((
48 -For Dragino End Node, user can access to the device console and run AT Command "**AT+NJM=0**" to set it to ABP mode.
61 +For Dragino End Node, user can access to the device console and run AT Command "(% style="color:blue" %)**AT+NJM=0**(%%)" to set it to ABP mode.
49 49  )))
50 50  )))
51 51  
52 52  (((
53 53  (((
54 -User can know the keys by run **AT+CFG**.
67 +User can know the keys by run (% style="color:blue" %)**AT+CFG**.
68 +
69 +
55 55  )))
56 56  )))
57 57  
... ... @@ -65,19 +65,21 @@
65 65  
66 66  Create ABP Device
67 67  
68 -And input the keys:
69 69  
70 -* Device EUI : Use the value from AT+DEUI
71 -* Device ADDR: Use the value from AT+DADDR
72 -* Application session key: Use the value from AT+APPSKEY
73 -* Network Session Key: Use the value from AT+NWKSKEY
84 +**(% style="color:blue" %)And input the keys:**
74 74  
86 +* **(% style="color:#037691" %)Device EUI : ** (%%) Use the value from AT+DEUI
87 +* **(% style="color:#037691" %)Device ADDR:**(%%)  Use the value from AT+DADDR
88 +* **(% style="color:#037691" %)Application session key:** (%%) Use the value from AT+APPSKEY
89 +* **(% style="color:#037691" %)Network Session Key:** (%%) Use the value from AT+NWKSKEY
90 +
75 75  [[image:image-20220524181549-6.png]]
76 76  
77 77  Create ABP Device
78 78  
95 +
79 79  After Successfule uplink, User will be to see the activity:
80 80  
81 -[[image:image-20220524181604-7.png]]
98 +[[image:image-20220526114506-2.png]]
82 82  
83 83  ABP Device Info
image-20220526114540-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +106.0 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0