1.2 | 1 | = OTAA Join Fail Issue = |
![]() |
1.1 | 2 | |
![]() |
1.2 | 3 | ---- |
![]() |
1.1 | 4 | |
![]() |
1.2 | 5 | ((( |
6 | The reason of fail to join Objenious is that our end node use RX2DR=3 for join. this is the default setting for TTN and many LoRaWAN servers. | ||
7 | ))) | ||
![]() |
1.1 | 8 | |
![]() |
1.2 | 9 | ((( |
10 | Objenious uses RX2DR=0 for Join, when Objenious sends a Join Accept, due to RX2DR different, the end node can not receive the Join Accept message from Objenious so keep joining. | ||
11 | ))) | ||
![]() |
1.1 | 12 | |
![]() |
1.2 | 13 | ((( |
14 | Some of End Nodes already support the change on RX2DR for OTAA join, in this case, use need to write AT+RX2DR=0. Please contact Dragino support for more info if the product doesn't support it. | ||