<
From version < 21.2 >
edited by Xiaoling
on 2023/04/12 15:41
To version < 21.5
edited by Xiaoling
on 2023/04/20 18:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,6 +10,7 @@
10 10  The Dragino LoRaWAN gateway can commuicate with LoRaWAN ABP End Node without the need of LoRaWAN server. It can be used in some cases such as:
11 11  
12 12  * No internet connection.
13 +
13 13  * User wants to get data forward in gateway and forward to their server base on MQTT/HTTP, etc. (Combine ABP communication method and [[MQTT forward together>>MQTT Forward Instruction]]).
14 14  
15 15  (((
... ... @@ -16,12 +16,14 @@
16 16  The basic of this feature is the decoding of (% style="color:red" %)**LoRaWAN ABP End Node**(%%). Requirements:
17 17  )))
18 18  
19 -1. LoRaWAN End Node in ABP mode. Make sure your end node works in this mode. End node most are default set to OTAA mode
20 -1. LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] ,[[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]]
21 -1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
20 +* LoRaWAN End Node in ABP mode. Make sure your end node works in this mode. End node most are default set to OTAA mode
22 22  
22 +* LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] ,[[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]]
23 23  
24 +* Firmware version for below instruction:  **[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
24 24  
26 +
27 +
25 25  = 2. How it works =
26 26  
27 27  
... ... @@ -81,7 +81,9 @@
81 81  )))
82 82  
83 83  * **RSSI**: 4646 4646 4646 3946 = 0xFFFF FF9F : So RSSI = (0xFFFF FF9F - 0x100000000) = -97
87 +
84 84  * **SNR**: 3030 3030 3030 3546 = 0x0000 005F = 95, need to divide 10 so SNR is 9.5
89 +
85 85  * **Payload**: 0xcc0c 0b63 0266 017f ff7f ff00
86 86  
87 87  (% class="box" %)
... ... @@ -161,10 +161,15 @@
161 161  **Some notice:**
162 162  
163 163  * RSSI and SNR are added when gateway receive the packet, so there is always this field.
169 +
164 164  * If you rename the file, please make it executable.
171 +
165 165  * See this link for lua.bit module: [[http:~~/~~/luaforge.net/projects/bit/>>url:http://luaforge.net/projects/bit/]]
173 +
166 166  * Lua json module: [[http:~~/~~/json.luaforge.net/>>url:http://json.luaforge.net/]]
175 +
167 167  * the last line return is what will be used for MQTT
177 +
168 168  * User can use other language ,not limited to Lua, just make sure the return is what you want to send.
169 169  
170 170  
... ... @@ -184,14 +184,19 @@
184 184  (% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow,Fport**
185 185  
186 186  * **dev_addr:** Inptu the device address
197 +
187 187  * **imme/time:**
188 188  ** imme: send downstream immediately,For Class C end node.
189 189  ** time: send downstream after receive device's uplink. For Class A end node
201 +
190 190  * **txt/hex:**
191 191  ** txt: send payload in ASCII
192 192  ** hex: send payload in HEX
205 +
193 193  * **payload: **payload to be sent, payload lenght should match the LoRaWAN protocol requirement.
207 +
194 194  * **txpw:** Transmit Power. example: 20
209 +
195 195  * **txbw:** bandwidth:
196 196  ** 1: 500 kHz
197 197  ** 2: 250 kHz
... ... @@ -198,28 +198,43 @@
198 198  ** 3: 125 kHz
199 199  ** 4: 62.5 kHz
200 200  * **SF:** Spreading Factor : SF7/SF8/SF9/SF10/SF11/SF12
216 +
201 201  * **Frequency:** Transmit Frequency: example: 923300000
218 +
202 202  * **rxwindow:** transmit on Rx1Window or Rx2Window.
220 +
203 203  * **Fport: **Transmit port,example:8
204 204  
223 +
205 205  (% style="color:blue" %)**Completely exmaple:**
206 206  
207 207  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
227 +
208 208  * **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2,8 > /var/iot/push/test
209 209  
210 -(% style="color:#037691" %)**Downstream Frequency:**
211 211  
231 +Downstream(% style="color:#037691" %)** Frequency:**
232 +
212 212  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
213 213  
214 214  * EU868: 869.525Mhz, DR0(SF12BW125)
236 +
215 215  * US915: 923.3Mhz, SF12 BW500
238 +
216 216  * CN470: 505.3Mhz, SF12 BW125
240 +
217 217  * AU915: 923.3Mhz, SF12 BW500
242 +
218 218  * AS923: 923.2Mhz, SF10 BW125
244 +
219 219  * KR920: 921.9Mhz, SF12 BW125
246 +
220 220  * IN865: 866.55Mhz, SF10 BW125
248 +
221 221  * RU864: 869.1Mhz, SF12 BW125
222 222  
251 +
252 +
223 223  (% style="color:#037691" %)**Examples:**
224 224  
225 225  (% class="box" %)
... ... @@ -360,9 +360,9 @@
360 360  
361 361  Full instruction video inlcude how to write scripts to fit server needed is here:
362 362  
363 -
364 364  (% style="color:#037691" %)**Video Instruction**(%%): **[[https:~~/~~/youtu.be/-nevW6U2TsE>>url:https://youtu.be/-nevW6U2TsE]]**
365 365  
395 +(% style="display:none" %) (%%)
366 366  
367 367  (% style="color:red" %)**Note: Firmware version must be higher than lgw-5.4.1607519907**
368 368  
... ... @@ -397,7 +397,7 @@
397 397  (% style="color:blue" %)**See value receive in socket tool:**
398 398  
399 399  
400 -[[image:image-20220527163144-11.png]]
430 +[[image:image-20220527163144-11.png||height="502" width="1371"]]
401 401  
402 402  value receive in socket tool
403 403  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0