Last modified by Xiaoling on 2023/04/20 18:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,6 +22,7 @@ 22 22 23 23 24 24 25 + 25 25 = 2. How it works = 26 26 27 27 ... ... @@ -45,10 +45,8 @@ 45 45 46 46 We need to input above keys in LG308 and enable ABP decryption. 47 47 48 - 49 49 [[image:image-20220527161119-1.png]] 50 50 51 - 52 52 Input the ABP keys in LG308 53 53 54 54 ... ... @@ -58,18 +58,14 @@ 58 58 Now when this End Node (Dev Addr=2602111D) send a uplink packet. When this packet arrive LG308, LG308 will decode it and put the decode data on the file /var/iot/channels/2602111D . So we have this data for further process with other applications in LG308. 59 59 60 60 ((( 61 -We can see the log of LG308 to know this packet arrive. 62 - 63 - 60 +We can see the log of LG308 to know this packet arrive 64 64 ))) 65 65 66 66 [[image:image-20220527161149-2.png]] 67 67 68 - 69 69 LG308 log by "(% style="color:red" %)**logread -f**" (%%)command 70 70 71 71 72 - 73 73 The data of End Node is stored in the file /var/iot/channels/2602111D. We can use hexdump command to check it. 74 74 75 75 (% class="box" %) ... ... @@ -94,7 +94,6 @@ 94 94 000001c 95 95 ))) 96 96 97 - 98 98 (% class="box" %) 99 99 ((( 100 100 (% style="color:red" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload. ... ... @@ -140,26 +140,23 @@ 140 140 Above scripts are store in /etc/lora/decoder/. User can put their scripts here and select it in the UI. 141 141 142 142 137 + 143 143 === 2.2.2 How to Decode My End Node === 144 144 145 145 146 - **1.**Configure the ABP keys for your end node in the gateway. enable ABP decode in Web UI141 +1/ Configure the ABP keys for your end node in the gateway. enable ABP decode in Web UI 147 147 148 - **2.**Don't choose MQTT service, use LoRaWAN.143 +2/ Don't choose MQTT service, use LoRaWAN. 149 149 150 - **3.**When your end node send a message to the gateway, there will be a file store in /var/iot/channels. full path should be /var/iot/channels/END_NODE_DEV_ADDR145 +3/ When your end node send a message to the gateway, there will be a file store in /var/iot/channels. full path should be /var/iot/channels/END_NODE_DEV_ADDR 151 151 152 - **4.**Use the /etc/lora/decoder/Dragino_LHT65 as template to decode your payload. This script is written in Lua language. User can manually call this script when you see the data file in /var/iot/channels by running:147 +4/ Use the /etc/lora/decoder/Dragino_LHT65 as template to decode your payload. This script is written in Lua language. User can manually call this script when you see the data file in /var/iot/channels by running: 153 153 154 154 {{{/etc/lora/decoder/Dragino_LHT65 END_NODE_DEV_ADDR 155 155 }}} 156 156 157 - **5.**What you see as output is the MQTT data device will upload, user's end node has different payload compare with LHT65, most properly this file will report with error. User need to modify to match the actual payload.152 +5/ What you see as output is the MQTT data device will upload, user's end node has different payload compare with LHT65, most properly this file will report with error. User need to modify to match the actual payload. Some notice: 158 158 159 - 160 -(% style="color:red" %) 161 -**Some notice:** 162 - 163 163 * RSSI and SNR are added when gateway receive the packet, so there is always this field. 164 164 * If you rename the file, please make it executable. 165 165 * See this link for lua.bit module: [[http:~~/~~/luaforge.net/projects/bit/>>url:http://luaforge.net/projects/bit/]] ... ... @@ -178,11 +178,10 @@ 178 178 179 179 (% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload** 180 180 172 +Since fimware > Dragino-v2 lgw-5.4.1608518541 . Support more option 181 181 182 - Sincefimware> [[Draginogw~~-~~-build-v5.4.1668567157>>https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG308-LG301/Firmware/Release/]] . Support moreoption174 +(% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow** 183 183 184 -(% style="color:#037691" %)**dev_addr,imme/time,txt/hex,payload,txpw,txbw,SF,frequency,rxwindow,Fport** 185 - 186 186 * **dev_addr:** Inptu the device address 187 187 * **imme/time:** 188 188 ** imme: send downstream immediately,For Class C end node. ... ... @@ -200,15 +200,17 @@ 200 200 * **SF:** Spreading Factor : SF7/SF8/SF9/SF10/SF11/SF12 201 201 * **Frequency:** Transmit Frequency: example: 923300000 202 202 * **rxwindow:** transmit on Rx1Window or Rx2Window. 203 -* **Fport: **Transmit port,example:8 204 204 194 + 195 + 205 205 (% style="color:blue" %)**Completely exmaple:** 206 206 207 207 * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test 208 -* **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 ,8> /var/iot/push/test199 +* **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test 209 209 210 -(% style="color:#037691" %)**Downstream Frequency:** 211 211 202 +(% style="color:#037691" %)**Downstream Frequency** 203 + 212 212 The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below: 213 213 214 214 * EU868: 869.525Mhz, DR0(SF12BW125) ... ... @@ -220,6 +220,7 @@ 220 220 * IN865: 866.55Mhz, SF10 BW125 221 221 * RU864: 869.1Mhz, SF12 BW125 222 222 215 + 223 223 (% style="color:#037691" %)**Examples:** 224 224 225 225 (% class="box" %) ... ... @@ -226,19 +226,25 @@ 226 226 ((( 227 227 we can use echo command to create files in LG308 for downstream. 228 228 root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test 222 +))) 229 229 230 - 224 +(% class="box" %) 225 +((( 231 231 **1)** From logread -f of gateway, we can see it has been added as pedning. 232 232 lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test 233 233 lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90 234 234 lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems). 230 +))) 235 235 236 - 232 +(% class="box" %) 233 +((( 237 237 **2)** When there is an upstrea from end node, this downstream will be sent and shows: 238 238 lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000) 239 239 lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17 237 +))) 240 240 241 - 239 +(% class="box" %) 240 +((( 242 242 **3)** and the end node will got: 243 243 [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~** 244 244 [5764827]TX on freq 905300000 Hz at DR 0 ... ... @@ -251,8 +251,10 @@ 251 251 Rssi= -41 252 252 Receive data 253 253 (% style="color:#037691" %)**2:12345678** (%%) ~-~-> Hex 253 +))) 254 254 255 - 255 +(% class="box" %) 256 +((( 256 256 **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got: 257 257 [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~** 258 258 [5955879]TX on freq 904100000 Hz at DR 0 ... ... @@ -311,42 +311,33 @@ 311 311 # whether the Device 2 has been changed.// 312 312 ))) 313 313 315 +**~1. Input keys** 314 314 315 -(% style="color:blue" %)**1. Input keys** 316 - 317 - 318 318 [[image:image-20220527162450-3.png]] 319 319 320 320 Input Keys in LPS8 321 321 322 322 322 +**2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.** 323 323 324 - (% style="color:blue" %)**2.Make sure the LPS8 and LT use the same frequency bands, chooseEU868inthistest.**324 +**3. Choose Built-in server** 325 325 326 - 327 -(% style="color:blue" %)**3. Choose Built-in server** 328 - 329 - 330 330 [[image:image-20220527162518-4.png]] 331 331 332 332 Choose Built-in server 333 333 334 334 331 +**4. Run the script.** 335 335 336 - (% style="color:blue" %)**4.Run the script.**333 +[[image:image-20220527162552-5.png]] 337 337 338 - 339 -[[image:image-20220722115213-2.png]] 340 - 341 341 Run the script 342 342 343 343 338 +**5. Output:** 344 344 345 - (% style="color:blue" %)**5.Output:**340 +[[image:image-20220527162619-6.png]] 346 346 347 - 348 -[[image:image-20220722115133-1.png]] 349 - 350 350 Output from LPS8 351 351 352 352 ... ... @@ -375,9 +375,8 @@ 375 375 376 376 377 377 378 - (% style="color:blue" %)**run socket tool in PC**370 +**run socket tool in PC** 379 379 380 - 381 381 [[image:image-20220527163028-9.png]] 382 382 383 383 ... ... @@ -385,9 +385,8 @@ 385 385 386 386 387 387 388 - (% style="color:blue" %)**Input Server address and port**379 +**Input Server address and port** 389 389 390 - 391 391 [[image:image-20220527163106-10.png]] 392 392 393 393 Input Server address and port ... ... @@ -394,9 +394,8 @@ 394 394 395 395 396 396 397 - (% style="color:blue" %)**See value receive in socket tool:**387 +**See value receive in socket tool:** 398 398 399 - 400 400 [[image:image-20220527163144-11.png]] 401 401 402 402 value receive in socket tool
- image-20220722115133-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.1 KB - Content
- image-20220722115213-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.7 KB - Content