Last modified by Xiaoling on 2023/04/20 18:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,8 +21,6 @@ 21 21 1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)** 22 22 23 23 24 - 25 - 26 26 = 2. How it works = 27 27 28 28 ... ... @@ -51,7 +51,6 @@ 51 51 Input the ABP keys in LG308 52 52 53 53 54 - 55 55 == 2.1 Upstream == 56 56 57 57 ... ... @@ -80,8 +80,6 @@ 80 80 * **SNR**: 3030 3030 3030 3546 = 0x0000 005F = 95, need to divide 10 so SNR is 9.5 81 81 * **Payload**: 0xcc0c 0b63 0266 017f ff7f ff00 82 82 83 - 84 - 85 85 (% class="box" %) 86 86 ((( 87 87 (% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below: ... ... @@ -92,7 +92,6 @@ 92 92 000001c 93 93 ))) 94 94 95 - 96 96 (% class="box" %) 97 97 ((( 98 98 (% style="color:red" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload. ... ... @@ -99,7 +99,6 @@ 99 99 ))) 100 100 101 101 102 - 103 103 === 2.2.1 Decode Method === 104 104 105 105 ... ... @@ -169,7 +169,6 @@ 169 169 170 170 171 171 172 - 173 173 == 2.2 Downstream == 174 174 175 175 ... ... @@ -225,19 +225,25 @@ 225 225 ((( 226 226 we can use echo command to create files in LG308 for downstream. 227 227 root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test 220 +))) 228 228 229 - 222 +(% class="box" %) 223 +((( 230 230 **1)** From logread -f of gateway, we can see it has been added as pedning. 231 231 lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test 232 232 lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90 233 233 lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems). 228 +))) 234 234 235 - 230 +(% class="box" %) 231 +((( 236 236 **2)** When there is an upstrea from end node, this downstream will be sent and shows: 237 237 lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000) 238 238 lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17 235 +))) 239 239 240 - 237 +(% class="box" %) 238 +((( 241 241 **3)** and the end node will got: 242 242 [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~** 243 243 [5764827]TX on freq 905300000 Hz at DR 0 ... ... @@ -250,8 +250,10 @@ 250 250 Rssi= -41 251 251 Receive data 252 252 (% style="color:#037691" %)**2:12345678** (%%) ~-~-> Hex 251 +))) 253 253 254 - 253 +(% class="box" %) 254 +((( 255 255 **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got: 256 256 [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~** 257 257 [5955879]TX on freq 904100000 Hz at DR 0 ... ... @@ -267,7 +267,6 @@ 267 267 ))) 268 268 269 269 270 - 271 271 = 3. Example 1: Communicate with LT-22222-L = 272 272 273 273 ... ... @@ -311,7 +311,6 @@ 311 311 # whether the Device 2 has been changed.// 312 312 ))) 313 313 314 - 315 315 **~1. Input keys** 316 316 317 317 [[image:image-20220527162450-3.png]] ... ... @@ -321,7 +321,6 @@ 321 321 322 322 **2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.** 323 323 324 - 325 325 **3. Choose Built-in server** 326 326 327 327 [[image:image-20220527162518-4.png]] ... ... @@ -331,7 +331,7 @@ 331 331 332 332 **4. Run the script.** 333 333 334 -[[image:image-20220 722115213-2.png]]331 +[[image:image-20220527162552-5.png]] 335 335 336 336 Run the script 337 337 ... ... @@ -338,12 +338,11 @@ 338 338 339 339 **5. Output:** 340 340 341 -[[image:image-2022072 2115133-1.png]]338 +[[image:image-20220527162619-6.png]] 342 342 343 343 Output from LPS8 344 344 345 345 346 - 347 347 = 4. Example 2: Communicate to TCP Server = 348 348 349 349
- image-20220722115133-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.1 KB - Content
- image-20220722115213-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.7 KB - Content