<
From version < 18.2 >
edited by Xiaoling
on 2022/07/22 11:52
To version < 16.3 >
edited by Xiaoling
on 2022/07/22 11:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -77,7 +77,6 @@
77 77  * **SNR**: 3030 3030 3030 3546 = 0x0000 005F = 95, need to divide 10 so SNR is 9.5
78 78  * **Payload**: 0xcc0c 0b63 0266 017f ff7f ff00
79 79  
80 -
81 81  (% class="box" %)
82 82  (((
83 83  (% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:
... ... @@ -196,6 +196,7 @@
196 196  
197 197  
198 198  
198 +
199 199  (% style="color:blue" %)**Completely exmaple:**
200 200  
201 201  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
... ... @@ -203,6 +203,7 @@
203 203  
204 204  
205 205  
206 +
206 206  (% style="color:#037691" %)**Downstream Frequency**
207 207  
208 208  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
... ... @@ -218,6 +218,7 @@
218 218  
219 219  
220 220  
222 +
221 221  (% style="color:#037691" %)**Examples:**
222 222  
223 223  (% class="box" %)
... ... @@ -224,19 +224,25 @@
224 224  (((
225 225  we can use echo command to create files in LG308 for downstream.
226 226  root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test
229 +)))
227 227  
228 -
231 +(% class="box" %)
232 +(((
229 229  **1)** From logread -f of gateway, we can see it has been added as pedning.
230 230  lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test
231 231  lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90
232 232  lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems).
237 +)))
233 233  
234 -
239 +(% class="box" %)
240 +(((
235 235  **2)** When there is an upstrea from end node, this downstream will be sent and shows:
236 236  lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000)
237 237  lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17
244 +)))
238 238  
239 -
246 +(% class="box" %)
247 +(((
240 240  **3)** and the end node will got:
241 241  [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~**
242 242  [5764827]TX on freq 905300000 Hz at DR 0
... ... @@ -249,8 +249,10 @@
249 249  Rssi= -41
250 250  Receive data
251 251  (% style="color:#037691" %)**2:12345678**  (%%) ~-~-> Hex
260 +)))
252 252  
253 -
262 +(% class="box" %)
263 +(((
254 254  **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got:
255 255  [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~**
256 256  [5955879]TX on freq 904100000 Hz at DR 0
... ... @@ -309,7 +309,6 @@
309 309  #  whether the Device 2 has been changed.//
310 310  )))
311 311  
312 -
313 313  **~1. Input keys**
314 314  
315 315  [[image:image-20220527162450-3.png]]
... ... @@ -319,7 +319,6 @@
319 319  
320 320  **2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.**
321 321  
322 -
323 323  **3. Choose Built-in server**
324 324  
325 325  [[image:image-20220527162518-4.png]]
... ... @@ -329,7 +329,7 @@
329 329  
330 330  **4. Run the script.**
331 331  
332 -[[image:image-20220722115213-2.png]]
340 +[[image:image-20220527162552-5.png]]
333 333  
334 334  Run the script
335 335  
... ... @@ -336,7 +336,7 @@
336 336  
337 337  **5. Output:**
338 338  
339 -[[image:image-20220722115133-1.png]]
347 +[[image:image-20220527162619-6.png]]
340 340  
341 341  Output from LPS8
342 342  
image-20220722115133-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -35.1 KB
Content
image-20220722115213-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -27.7 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0