<
From version < 17.1 >
edited by Xiaoling
on 2022/07/22 11:51
To version < 18.6 >
edited by Xiaoling
on 2022/07/22 12:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,6 +22,7 @@
22 22  
23 23  
24 24  
25 +
25 25  = 2. How it works =
26 26  
27 27  
... ... @@ -50,6 +50,7 @@
50 50  Input the ABP keys in LG308
51 51  
52 52  
54 +
53 53  == 2.1 Upstream ==
54 54  
55 55  
... ... @@ -90,6 +90,7 @@
90 90  000001c
91 91  )))
92 92  
95 +
93 93  (% class="box" %)
94 94  (((
95 95  (% style="color:red" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload.
... ... @@ -96,6 +96,7 @@
96 96  )))
97 97  
98 98  
102 +
99 99  === 2.2.1 Decode Method ===
100 100  
101 101  
... ... @@ -197,17 +197,11 @@
197 197  * **Frequency:** Transmit Frequency: example: 923300000
198 198  * **rxwindow:** transmit on Rx1Window or Rx2Window.
199 199  
200 -
201 -
202 -
203 203  (% style="color:blue" %)**Completely exmaple:**
204 204  
205 205  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
206 206  * **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test
207 207  
208 -
209 -
210 -
211 211  (% style="color:#037691" %)**Downstream Frequency**
212 212  
213 213  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
... ... @@ -221,9 +221,6 @@
221 221  * IN865: 866.55Mhz, SF10 BW125
222 222  * RU864: 869.1Mhz, SF12 BW125
223 223  
224 -
225 -
226 -
227 227  (% style="color:#037691" %)**Examples:**
228 228  
229 229  (% class="box" %)
... ... @@ -272,6 +272,7 @@
272 272  )))
273 273  
274 274  
270 +
275 275  = 3. Example 1: Communicate with LT-22222-L =
276 276  
277 277  
... ... @@ -335,7 +335,7 @@
335 335  
336 336  **4. Run the script.**
337 337  
338 -[[image:image-20220527162552-5.png]]
334 +[[image:image-20220722115213-2.png]]
339 339  
340 340  Run the script
341 341  
... ... @@ -342,11 +342,12 @@
342 342  
343 343  **5. Output:**
344 344  
345 -[[image:image-20220527162619-6.png]]
341 +[[image:image-20220722115133-1.png]]
346 346  
347 347  Output from LPS8
348 348  
349 349  
346 +
350 350  = 4. Example 2: Communicate to TCP Server =
351 351  
352 352  
image-20220722115213-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +27.7 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0