<
From version < 16.9 >
edited by Xiaoling
on 2022/07/22 11:47
To version < 16.3 >
edited by Xiaoling
on 2022/07/22 11:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -21,8 +21,6 @@
21 21  1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
22 22  
23 23  
24 -
25 -
26 26  = 2. How it works =
27 27  
28 28  
... ... @@ -79,9 +79,6 @@
79 79  * **SNR**: 3030 3030 3030 3546 = 0x0000 005F = 95, need to divide 10 so SNR is 9.5
80 80  * **Payload**: 0xcc0c 0b63 0266 017f ff7f ff00
81 81  
82 -
83 -
84 -
85 85  (% class="box" %)
86 86  (((
87 87  (% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:
... ... @@ -167,8 +167,6 @@
167 167  
168 168  
169 169  
170 -
171 -
172 172  == 2.2 Downstream ==
173 173  
174 174  
... ... @@ -201,6 +201,8 @@
201 201  * **rxwindow:** transmit on Rx1Window or Rx2Window.
202 202  
203 203  
197 +
198 +
204 204  (% style="color:blue" %)**Completely exmaple:**
205 205  
206 206  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
... ... @@ -207,6 +207,8 @@
207 207  * **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test
208 208  
209 209  
205 +
206 +
210 210  (% style="color:#037691" %)**Downstream Frequency**
211 211  
212 212  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
... ... @@ -221,6 +221,8 @@
221 221  * RU864: 869.1Mhz, SF12 BW125
222 222  
223 223  
221 +
222 +
224 224  (% style="color:#037691" %)**Examples:**
225 225  
226 226  (% class="box" %)
... ... @@ -227,19 +227,25 @@
227 227  (((
228 228  we can use echo command to create files in LG308 for downstream.
229 229  root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test
229 +)))
230 230  
231 -
231 +(% class="box" %)
232 +(((
232 232  **1)** From logread -f of gateway, we can see it has been added as pedning.
233 233  lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test
234 234  lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90
235 235  lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems).
237 +)))
236 236  
237 -
239 +(% class="box" %)
240 +(((
238 238  **2)** When there is an upstrea from end node, this downstream will be sent and shows:
239 239  lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000)
240 240  lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17
244 +)))
241 241  
242 -
246 +(% class="box" %)
247 +(((
243 243  **3)** and the end node will got:
244 244  [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~**
245 245  [5764827]TX on freq 905300000 Hz at DR 0
... ... @@ -252,8 +252,10 @@
252 252  Rssi= -41
253 253  Receive data
254 254  (% style="color:#037691" %)**2:12345678**  (%%) ~-~-> Hex
260 +)))
255 255  
256 -
262 +(% class="box" %)
263 +(((
257 257  **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got:
258 258  [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~**
259 259  [5955879]TX on freq 904100000 Hz at DR 0
... ... @@ -312,7 +312,6 @@
312 312  #  whether the Device 2 has been changed.//
313 313  )))
314 314  
315 -
316 316  **~1. Input keys**
317 317  
318 318  [[image:image-20220527162450-3.png]]
... ... @@ -322,7 +322,6 @@
322 322  
323 323  **2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.**
324 324  
325 -
326 326  **3. Choose Built-in server**
327 327  
328 328  [[image:image-20220527162518-4.png]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0