<
From version < 16.8 >
edited by Xiaoling
on 2022/07/22 11:46
To version < 16.3 >
edited by Xiaoling
on 2022/07/22 11:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -21,8 +21,6 @@
21 21  1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
22 22  
23 23  
24 -
25 -
26 26  = 2. How it works =
27 27  
28 28  
... ... @@ -162,6 +162,8 @@
162 162  * the last line return is what will be used for MQTT
163 163  * User can use other language ,not limited to Lua, just make sure the return is what you want to send.
164 164  
163 +
164 +
165 165  == 2.2 Downstream ==
166 166  
167 167  
... ... @@ -194,6 +194,8 @@
194 194  * **rxwindow:** transmit on Rx1Window or Rx2Window.
195 195  
196 196  
197 +
198 +
197 197  (% style="color:blue" %)**Completely exmaple:**
198 198  
199 199  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
... ... @@ -200,6 +200,8 @@
200 200  * **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test
201 201  
202 202  
205 +
206 +
203 203  (% style="color:#037691" %)**Downstream Frequency**
204 204  
205 205  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
... ... @@ -214,6 +214,8 @@
214 214  * RU864: 869.1Mhz, SF12 BW125
215 215  
216 216  
221 +
222 +
217 217  (% style="color:#037691" %)**Examples:**
218 218  
219 219  (% class="box" %)
... ... @@ -220,19 +220,25 @@
220 220  (((
221 221  we can use echo command to create files in LG308 for downstream.
222 222  root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test
229 +)))
223 223  
224 -
231 +(% class="box" %)
232 +(((
225 225  **1)** From logread -f of gateway, we can see it has been added as pedning.
226 226  lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test
227 227  lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90
228 228  lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems).
237 +)))
229 229  
230 -
239 +(% class="box" %)
240 +(((
231 231  **2)** When there is an upstrea from end node, this downstream will be sent and shows:
232 232  lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000)
233 233  lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17
244 +)))
234 234  
235 -
246 +(% class="box" %)
247 +(((
236 236  **3)** and the end node will got:
237 237  [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~**
238 238  [5764827]TX on freq 905300000 Hz at DR 0
... ... @@ -245,8 +245,10 @@
245 245  Rssi= -41
246 246  Receive data
247 247  (% style="color:#037691" %)**2:12345678**  (%%) ~-~-> Hex
260 +)))
248 248  
249 -
262 +(% class="box" %)
263 +(((
250 250  **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got:
251 251  [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~**
252 252  [5955879]TX on freq 904100000 Hz at DR 0
... ... @@ -305,7 +305,6 @@
305 305  #  whether the Device 2 has been changed.//
306 306  )))
307 307  
308 -
309 309  **~1. Input keys**
310 310  
311 311  [[image:image-20220527162450-3.png]]
... ... @@ -315,7 +315,6 @@
315 315  
316 316  **2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.**
317 317  
318 -
319 319  **3. Choose Built-in server**
320 320  
321 321  [[image:image-20220527162518-4.png]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0