<
From version < 16.5 >
edited by Xiaoling
on 2022/07/22 11:45
To version < 18.4 >
edited by Xiaoling
on 2022/07/22 11:59
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,6 +20,9 @@
20 20  1. LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] ,[[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]]
21 21  1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
22 22  
23 +
24 +
25 +
23 23  = 2. How it works =
24 24  
25 25  
... ... @@ -76,6 +76,9 @@
76 76  * **SNR**: 3030 3030 3030 3546 = 0x0000 005F = 95, need to divide 10 so SNR is 9.5
77 77  * **Payload**: 0xcc0c 0b63 0266 017f ff7f ff00
78 78  
82 +
83 +
84 +
79 79  (% class="box" %)
80 80  (((
81 81  (% style="color:red" %)**Notice 1**(%%): The data file stored in LG308 for the end node is bin file. If the end node sends ASCII string to gateway, the output will as below:
... ... @@ -86,6 +86,7 @@
86 86  000001c
87 87  )))
88 88  
95 +
89 89  (% class="box" %)
90 90  (((
91 91  (% style="color:red" %)**Notice 2**(%%): The upstream payload length should match the LoRaWAN length requirement (max length depends on Frequency and DR), otherwise the gateway can't decode the payload.
... ... @@ -92,6 +92,7 @@
92 92  )))
93 93  
94 94  
102 +
95 95  === 2.2.1 Decode Method ===
96 96  
97 97  
... ... @@ -192,7 +192,6 @@
192 192  * **rxwindow:** transmit on Rx1Window or Rx2Window.
193 193  
194 194  
195 -
196 196  (% style="color:blue" %)**Completely exmaple:**
197 197  
198 198  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
... ... @@ -199,7 +199,6 @@
199 199  * **New version:** echo 018193F4,imme,hex,0101,20,1,SF12,923300000,2 > /var/iot/push/test
200 200  
201 201  
202 -
203 203  (% style="color:#037691" %)**Downstream Frequency**
204 204  
205 205  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
... ... @@ -214,7 +214,6 @@
214 214  * RU864: 869.1Mhz, SF12 BW125
215 215  
216 216  
217 -
218 218  (% style="color:#037691" %)**Examples:**
219 219  
220 220  (% class="box" %)
... ... @@ -306,6 +306,7 @@
306 306  #  whether the Device 2 has been changed.//
307 307  )))
308 308  
314 +
309 309  **~1. Input keys**
310 310  
311 311  [[image:image-20220527162450-3.png]]
... ... @@ -315,6 +315,7 @@
315 315  
316 316  **2. Make sure the LPS8 and LT use the same frequency bands, choose EU868 in this test.**
317 317  
324 +
318 318  **3. Choose Built-in server**
319 319  
320 320  [[image:image-20220527162518-4.png]]
... ... @@ -324,7 +324,7 @@
324 324  
325 325  **4. Run the script.**
326 326  
327 -[[image:image-20220527162552-5.png]]
334 +[[image:image-20220722115213-2.png]]
328 328  
329 329  Run the script
330 330  
... ... @@ -331,7 +331,7 @@
331 331  
332 332  **5. Output:**
333 333  
334 -[[image:image-20220527162619-6.png]]
341 +[[image:image-20220722115133-1.png]]
335 335  
336 336  Output from LPS8
337 337  
image-20220722115133-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +35.1 KB
Content
image-20220722115213-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +27.7 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0