<
From version < 16.5 >
edited by Xiaoling
on 2022/07/22 11:45
To version < 16.3 >
edited by Xiaoling
on 2022/07/22 11:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,6 +20,7 @@
20 20  1. LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] ,[[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]]
21 21  1. Firmware version for below instruction:**[[(% style="color:purple" %)Since LG02_LG08~~-~~-build-v5.4.1593400722-20200629-1120>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]](%%)**
22 22  
23 +
23 23  = 2. How it works =
24 24  
25 25  
... ... @@ -160,6 +160,7 @@
160 160  * User can use other language ,not limited to Lua, just make sure the return is what you want to send.
161 161  
162 162  
164 +
163 163  == 2.2 Downstream ==
164 164  
165 165  
... ... @@ -193,6 +193,7 @@
193 193  
194 194  
195 195  
198 +
196 196  (% style="color:blue" %)**Completely exmaple:**
197 197  
198 198  * **Old version:** echo 018193F4,imme,hex,0101 > /var/iot/push/test
... ... @@ -200,6 +200,7 @@
200 200  
201 201  
202 202  
206 +
203 203  (% style="color:#037691" %)**Downstream Frequency**
204 204  
205 205  The LG308 will use the RX2 window info to send the downstream payload, use the default LoRaWAN settings, as below:
... ... @@ -215,6 +215,7 @@
215 215  
216 216  
217 217  
222 +
218 218  (% style="color:#037691" %)**Examples:**
219 219  
220 220  (% class="box" %)
... ... @@ -221,19 +221,25 @@
221 221  (((
222 222  we can use echo command to create files in LG308 for downstream.
223 223  root@dragino-1d25dc:~~# echo 2602111D,time,hex,12345678 > /var/iot/push/test
229 +)))
224 224  
225 -
231 +(% class="box" %)
232 +(((
226 226  **1)** From logread -f of gateway, we can see it has been added as pedning.
227 227  lora_pkt_fwd[4286]: INFO~~ [DNLK]Looking file : test
228 228  lora_pkt_fwd[4286]: INFO~~ [DNLK]devaddr:2602111D, txmode:time, pdfm:hex, size:4, payload1:4Vx,payload_hex:77C1BB90
229 229  lora_pkt_fwd[4286]: INFO~~ [DNLK] DNLINK PENDING!(1 elems).
237 +)))
230 230  
231 -
239 +(% class="box" %)
240 +(((
232 232  **2)** When there is an upstrea from end node, this downstream will be sent and shows:
233 233  lora_pkt_fwd[4286]: INFO: tx_start_delay=1497 (1497.000000) - (1497, bw_delay=0.000000, notch_delay=0.000000)
234 234  lora_pkt_fwd[4286]: [LGWSEND]lgw_send done: count_us=3537314420, freq=923300000, size=17
244 +)))
235 235  
236 -
246 +(% class="box" %)
247 +(((
237 237  **3)** and the end node will got:
238 238  [5764825]~*~*~*~** UpLinkCounter= 98 ~*~*~*~**
239 239  [5764827]TX on freq 905300000 Hz at DR 0
... ... @@ -246,8 +246,10 @@
246 246  Rssi= -41
247 247  Receive data
248 248  (% style="color:#037691" %)**2:12345678**  (%%) ~-~-> Hex
260 +)))
249 249  
250 -
262 +(% class="box" %)
263 +(((
251 251  **4) **If we use the command "echo 2602111D,time,txt,12345678 > /var/iot/push/test" for downstream, the end node will got:
252 252  [5955877]~*~*~*~** UpLinkCounter= 102 ~*~*~*~**
253 253  [5955879]TX on freq 904100000 Hz at DR 0
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0